background image

Fasep 2000 srl

Rev. 1.3

Videotronic V653.G2: User’s Manual

02 april 2010

2-4

Key SET/OK 

Double operator

Optimize

Restart software

Reset partial statistics

Reset variation in page Sensor

Save

Set measures

Go to setup menù

Skip current operation

Split function

Stop turning wheel

Key up

View menù and selection
(UP/DOWN

Automatic flange calibration

Fig. 26

Fig. 27

Fig. 28

Fig. 29

Fig. 30

Fig. 31

Fig. 32

Fig. 33

Fig. 34

Fig. 35

Fig. 36

Fig. 37

Fig. 38

Fig. 39

Fig. 40

Содержание VIDEOTRONIC V653.G2

Страница 1: ...V653 G2 User s Manual 02 april 2010 For any information please contact www fasep it e mail info fasep it FASEP 2000 srl Via Faentina 96 50032 Ronta Fi Italy Tel 39 055 840 3126 Fax 39 055 840 3354 i...

Страница 2: ...ience breakdown accidents due to unauthorized modifications of the unit use of non original or unauthorized accessories see Accessories listing in this manual for a list of original accessories availa...

Страница 3: ...on weight 3 2 5 Calibration ALU SE 4 1 6 Calibration SME 4 2 7 MEASUREMENT AND CORRECTION OF UMBALANCE 4 3 7 1 Placing the wheel rim on the wheel balancer 4 3 7 2 Input of Rim Dimensions external meas...

Страница 4: ...or use only see Environmental Data appendix for reference CAUTION This unit is designed to spin vehicle wheels only within the range of dimensions and weight approved see Technical Data appendix for r...

Страница 5: ...lug connectors 2 4 4 The balancer must be effectively connected to ground The electric cord is regularly provided with a ground terminal 2 4 5 Make sure that Power Rate Specifications for your wheel b...

Страница 6: ...pril 2010 2 2 3 USE OF CONTROL PANEL 3 1 Meaning of the icons on the screen Select balancing mode APS Function Calibration Delete last character in input activation code Change selection Set default v...

Страница 7: ...previous page Fine resolution Access to Information center Access to page measures Laser calibration Put in the rod laser in rest position Start laser Extract fully rod laser Manul input measures Set...

Страница 8: ...ware Reset partial statistics Reset variation in page Sensor Save Set measures Go to setup men Skip current operation Split function Stop turning wheel Key up View men and selection UP DOWN Automatic...

Страница 9: ...3 Videotronic V653 G2 User s Manual 02 april 2010 2 5 3 2 Meaning of the command keys Disable open pneumatic lock safety for flange use Open close pneumatic lock Tilting Open close wheel guard Fig 41...

Страница 10: ...tant low or high weight readings c indicated point of unbalance constantly wrong d more than 2 spins required to balance wheels repeatedly Switch on the wheel balancer Select SET UP CALIBRATION SET OK...

Страница 11: ...ET OK CHECK CALIBRATION SET OK Put a wheel on the shaft and press START Fig50 Put the calibration weight Fig 51 and press SET OK Close the wheel guard or press START At the end of the spin 160 0 will...

Страница 12: ...balancer MAIN MENU MENU RESET CALIB ALU SE CALIBRATION SET OK fig 53 Put the rod on rest position fig 53 and press SET OK Put the rod on the flange fig 54 and press SET OK Select width of wheel Put th...

Страница 13: ...april 2010 4 2 6 Calibration SME Switch on the wheel balancer MAIN MENU MENU RESET CALIB SME CALIBRATION SET OK fig 56 Put the rod on rest position fig 56 and press SET OK Put the rod fig 57 and pres...

Страница 14: ...entering and tightening of the wheel on the flanges is of basic importance for correct balancing Good results depend on proper performance of these procedures To accurately clean up the superficial on...

Страница 15: ...stance IN2 Press ALU MODE untill the required position of weight is on the video fig 61 Insert the distance IN1 Insert the distance IN2 7 4 Detecting and correcting umbalance 7 4 1 After setting wheel...

Страница 16: ...e weight using LASER Turn the wheel until the position weight indicators of one side are both green fig 68 The laser come out to show the point of application of the weight fig 69 Apply the weight on...

Страница 17: ...e rim and put the wheel on the shaft fig 71 Spin the wheel Select the optimization and follow the video instruction WARNING Balancing with flanges put the accessories assembled to the rim during the c...

Страница 18: ...ge and press SET OK 9 2 Setup 9 2 1 MAIN MENU SET UP USER SET UP 9 2 2 Select item and press SET OK 9 3 Personalization 9 3 1 MAIN MENU PERSONAL 9 3 2 Follow the instruction on video to insert the per...

Страница 19: ...nt 400W Speed Balancing 98RPM Measuring time 4 15 s Accuracy 1grammo 1 28 once Wheel Dimensions Diameter Rim diameter 8 200 mm 26 650 mm Rim Width with wheel guard max 16 415mm Wheel Weight max 90 Kg...

Страница 20: ...directly by unauthorized service Service to any parts by unauthorized engineers will void warranty and will any right of the owner of the unit NOTE As this unit runs at speed below 100rpm a safety cov...

Страница 21: ...ellow red padlock functions as emergency stop E Quick connection to air pipe allows the detachment from the air F Filter regulator regulates the air pressure input to avoid overpressure inside the pne...

Страница 22: ...operating pressure 9M2517 Warning danger 9M3012 Tape yellow black 2M2493 Danger of crushing 2M1632 Specific power 2M2323 Parking brake In case of poor readability or damaged plates applied to the mac...

Страница 23: ...ver is open ERR 7 Measuring cycle was interrupted ERR 8 Calibration weight was not inserted ERR 9 Activation code not correct ERR 10 Overflow in calculations ERR 11 Serial number is wrong ERR 12 Seria...

Страница 24: ...nsequences for the environment and human health which could otherwise be caused by inappropriate waste handling of the battery The recycling of the materials will help to conserve natural resources In...

Отзывы: