25
Revision date: 09.25.18
115277
9
INSTALL THE MAIN PUMP & PLUMBING
Install the Main Pump and Plumbing
• Dry fit all connections before applying pvc primer and cement.
• Install the WF1030 Y-filter with the water-flow direction arrow pointing away from the pump.
• Center reservoir so bulkhead fitting points toward the supply manifold end of the frame.
Gather parts identified in the photo and construct main pump supply plumbing. Review assembly and installation
notes that follow before you begin. For best results, complete this procedure after setting frame slope.
WARNING:
All electrical
wiring to be completed
by a qualified electrician
according to recognized
local building codes.
WF1570
From Pump
WF1570
WF2190
111045
WF2190
WF3420
WF6682
WF1030
WF3420
1" PVC
1" PVC
WF1380 tee
fitting at the
end of the
pvc manifold.
Water Flow
A
See A in diagram below.
WF1570
water flow
Supply
Manifold
End
1/4"
Nutrient
Tube
Drain
Manifold
End
2" Drain
PVC
Reservoir
113536
Pump
113537
Unions
A
Side View of System
Drain
Drain
NOTE:
Secure
pump to mounting
surface to reduce
vibration.
See A in diagram above.
Bulkhead Fitting &
WF2193 Adapter