17
Revision date: 09.25.18
111628M
3
ASSEMBLE THE DRAIN MANIFOLD
Required parts:
• 111560 2" PVC Pipe, WF6717 Slip Caps, and 111696
Double Hub (Cross Fitting)
• 111906 1" Sammys and 111907 Conduit Hangers
• FAK26 Threaded Rods and FALB04B Nuts
• 113372 Primer and WF6990 PVC Cement
Assembly Instructions
Complete these steps:
1. Cut 8 horizontal tubes at 24" each. Use the 2" (111560) PVC.
2. Clean the ends of the PVC tubes to remove any loose material.
3. Mark the hole locations on each 24" tube and drill the holes for the drain
elbows of the channels. Use a
1 3/8" hole saw bit
and a drill. (If possible,
drill the holes in the PVC tube using a drill press for accuracy.) Remove
loose material from around the holes and from inside each tube.
4. After cleaning each 24" tube, attach the WF6717 slip cap to the end of the
tube as shown.
DO NOT CEMENT THE CAPS TO THE TUBES. Caps
must remain free for cleaning of the tubes. Set these tubes aside for
later assembly of the drain manifold.
5. Using the 111560 2" PVC pipe, cut three (3) pieces at 8".
6. Take the 111696 cross fittings and 8" tubes and assemble the center stack
of the drain manifold as shown.
Use PVC primer and cement to attach
the vertical 8" tubes to the cross fittings.
Assemble on a flat surface for
best results and to keep the fittings aligned.
STEP 3
24"
8"
10 1/2"
Center Line
8"
WF6717 Slip Cap–
Do not cement.
111696
Cross Fitting
111696
Cross Fitting
111696
Cross Fitting
111696
Cross Fitting
TOP
BOTTOM
DRAIN MANIFOLD –
CENTER STACK
Length
of each
tube: 8"
NOTE:
Cement all 8" PVC sections to
the 111696 Cross Fittings using primer
and pvc cement.
For best results, use a step bit if
available to drill the holes in the pvc
tubing.