CH10
26
M12x180
M12 DIN 985
M10x25
M10 DIN 985
100Nm
KNIFE AND ANVIL MAINTENANCE
Read the safety instructions.
The disk continues rotating like a fly
-
wheel after the PTO is disengaged.
Please wait until the disk has stop-
ped completely before performing
any further actions.
When manually turning the rotor,
never touch the edges of the lower
chamber or other parts where the-
re is the risk for the hands to get
squeezed between the lower cham-
ber and the rotor knives or blades.
OPENING AND REMOVING THE UPPER CHAMBER
• Remove the M10 mounting bolts of the upper cham-
ber. Swing the upper chamber to the side.
• Remove the M12 pin to release the upper chamber.
Exercise extreme caution when
opening the upper chamber. Take
appropriate measures to keep the
upper chamber from falling down.
REMOVING THE KNIVES
1. Remove the knife fastening bolts (M12). Turn
the wrench in such a way that your hands would
not hit the knife if the wrench should slip. Fig. 12.
Wear protective gloves when hand-
ling knives or anvils.
Fig. 11. Removing the upper chamber
Fig. 12. Removing the knife fastening bolts