6.5
CONNECTING PROCEDURE
1.
Installation of the controller in the tractor cabin
2.
Connection with the machine
3.
Connection with the electric source
4.
System activation using the Power button
5.
Circuit selection
6.6
EMERGENCY STATE
A defect in the electric installation or the tractor power supply is considered to be an emergency state. When
completely disconnected, turned off or in the case of a failure, it is always possible to control the Frame Locking
circuit (as an initial one, with a reversed switching function).
Manual emergency control
The switchboard may be controlled mechanically in emergency
The control is performed by manually pressing the gate valve of the switchboard via the spring (e.g., using a
suitable bar with a diameter of about 3 mm)
The switchboard cover has holes on the bottom side for this case
Example: “Frame Folding” circuit control
Close this circuit by pressing the gate valve of the “Frame Protection” (the gate valve has a
reversed function, the circuit is open without voltage)
Open this circuit be pressing the “Frame Folding” gate valve
Control the selected circuit by the oil pressure from the tractor
Holes for
emergency
control
Front
equipment
Frame locking
Frame folding