23
│
25
Manual
KULTIS 6 | KULTIS 8
5. Maintenance and Storage of the Machine
5.1.
Daily Inspection
1. Check the tightness of the connections of the liquid fertilizer application equipment.
2. Perform the tasks described in the Application Equipment chapter.
3. Check the tightness of the hydraulic system.
4. Check the screw connections.
Cleaning the filter
– stop the three-way valve in front of the filter, demount the filter and clean it.
The filter is cleaned once a day according to the cleanliness of the fluid.
5.2.
Seasonal Inspection
1. Clean the machine and repair any damaged coating.
2. Thoroughly rinse the application equipment with water and empty it of any fluid completely.
3. Replenish the grease in the hubs of the landing wheels and coulters of the weeding units.
4. Preserve the extended parts of the piston rods of the hydraulic cylinders.
5.3.
Lubrication of the Machine
The feeler wheels and landing wheels are fitted with standard antifriction bearings. The
joints of the weeding units are fitted with special self-lubricating sleeves.
Lubrication Spot
Type of Lubricant
Lubrication Frequency
Chains of the pump drive
Dry lubricant
– Teflon
Daily
Chassis swivel pins
Universal grease
Daily
Travelling wheel hubs
Universal grease
Before and after season
Chassis suspension pins
Universal grease
Before and after season
Bearings of the pump drive
Universal grease
Before and after season
Pump
Motor oil
Daily inspection
5.4.
Storing the Machine
The machine may only stand on the rear wheels and front supporting legs when in
storage. The fertilizer tank must be empty.
ATTENTION: The machine must not be stored on the working units as such
storage would damage the working units.
Store the ends of the hydraulic hoses in the hose rack on the frame of the machine.
Thoroughly rinse the vehicle with water at the end of the season. When preparing the machine for
winter, make sure that there are no residues of water or fertilizer. Drain all fluids using the drain
valve. Disconnect the inlet hoses from the pump and let the water drain. Immediately rinse the
machine with water if contaminated with the application substance.