58
(MT12 - Gb2004)
Si 161L/1
I
NTERCOMS
*
V
IDEOINTERCOMS
*
T
ELECOMMUNICA
TION
ONE-WAY INTERCOMMUNICATING SYSTEM WITH SECONDARY DOOR STATIONS AND 1 MAIN COMMON STATION (multiple
entrance).
Q.ty
Article
Description
...
PT520
Project series modular intercom
...
PT501
Single button unit
1
PRS220
Power supply
X
PRS226E
Power supply-switcher
X
1473
Exchanger
1+X
PA **
Door release push-button (optional)
1+X
SE **
Electric door lock (12VAC-1A)
Door station series Mody (for right item set see on pages 12÷15)
Secondary door stations
X
MD71
Module frames with back box
X
MD11
Module for electric door speaker
X
MD81
Hood cover
X
MD91*
Rain shelter with module frames
X
MD30
Electric door speaker (amplifier)
Main entrance
1 row
2 row
...
MD71÷74
MD71÷74
Module frames with back box
1
MD10-11-12
MD10-122-124 Modules for electric door speaker
...
MD21 ÷ 24
MD222 ÷ 228
Button modules
...
MD20 - 50
MD20 - 50
Blank and info modules
1
MD82 ÷ 812
MD82 ÷ 812
Hood covers
1
MD92 ÷ 912*
MD92 ÷ 912*
Rain shelters with module frames
1
MD30
MD30
Electric door speaker (amplifier)
Door station series Matrix (for right item set see on pages 20 and 21)
Secondary door stations
X
MA71
Module frames with back box
X
MA11P
Module with integrated audio amplifier
X
MA61
Front frame
Main entrance
...
MA71÷73
Module frames with back box
1
MA10P-11P-12P
Modules with integrated audio amplifier
...
MA20-22-24
Blank and button modules
...
MA61÷63
Front frames
P
R
O
J
E
C
T
- In every intercommunicating intercom ap-
ply the single button group by connecting one
of the two button terminals to terminal 7 of
the power supply PRS226E.
- Do not use button no. 1 for intercommuni-
cating calls.
... Refers to number of users.
X Refers to the number of stairways.
* Rain shelters are used instead of back boxes and hood covers.
** Articles not supplied by ACI Farfisa.
Working instructions.
As the basic system described on page 27, with the following variations:
- The audio functions and door lock opening are automatically switched to the door
station which has made the call and remain in this state until a call from another
entrance is received.
- Services to secondary door stations are independent and can be operated at the
same time.
Notes
- For the connection of name-plate lamps, read notes 6 and 7 of the installation
instructions on page 26.
- For wires dimensioning refer to the installation recommendations and table on page
26.
- For other types of push-button panels see pages 22 and 23 or the general catalogue.
Number of inter-
Project
communicating
PT520
PT501
2
2
0
3
3
3
4
4
8
5
5
15
6
6
24
7
7
35
8
8
48
9
9
63
10
10
80
Table for choosing intercoms and accessories
for the required type of installation