6.1.1.2 Parametr IDx=y
Parametr IDx=y okreœla minimaln¹ d³ugoœæ impulsu w sekun-
dach dla wejœcia 1 lub 2 (x=1 lub 2) do wyzwolenia alarmu.
D³ugoœæ impulsu (y) mo¿e zawieraæ siê w przedziale od 0.5
do 9999 sekund.
Dla wartoœci parametru 0 domyœlny czas
impulsu wynosi 0.5sekundy.
6.1.1.3 Parametr DDx=y
Parametr DDx=y jest u¿ywany do zdefiniowania opóŸnienia
w sekundach (y=0
÷9999) pomiêdzy wykryciem alarmu
na wejœciu a realizacji funkcji alarmowej przez urz¹dzenie.
6.1.1.2 IDx=y parameter
ID parameter determines the minimum length in seconds
of the pulse on input 1 or 2 (x=1 or 2) to trigger the alarm. The
pulse length (y) ranges from 0.5 to 9999 seconds.
The default time is 0.5 seconds when the parameters value
is 0.
6.1.1.3 DDx=y parameter
The parameter DDx=y is used to define the delay in seconds
(y=0÷9999) between the time the alarm input is triggered
and the time the alarm is acquired by the device.
Programowanie bezpoœrednio karty SIM
Kontakty
Nazwa Numer Opis
IN1
0
Alarm po zwarciu IN1 do masy (GND)
(GND)
IN2
4
Alarm po zwarciu IN2 do GND i wiadomoϾ
SMS po powrocie do normalnego stanu
ID1
10 IN1 musi byæ zwarte do masy przez 10
sekund aby wyzwoliæ alarm
ID2
10 IN2 musi byæ zwarte do masy przez 0,5
sekundy aby wyzwoliæ alarm
DD1
0
Zg³oszenie alarmu na wejœciu 1 jest
opóŸnione o 0 sekund
DD2
15
Zg³oszenie alarmu na wejœciu 2 jest
opóŸnione o 15 sekund
SMS
SIM
Zdalne programowanie przez SMS
;IN1=0;IN2=4;ID1=10;ID2=0;DD1=0;DD2=15;
Przyk³ad:
Zapisanie parametrów IN, ID oraz DD
Tabela 2. Znaczenie parametrów IN, ID i DD
Nazwa Opis
IN1
Tryb pracy dla wejœcia 1
IN2
Tryb pracy dla wejœcia 2
ID1
D³ugoœæ impulsu na wejœciu 1
ID2
D³ugoœæ impulsu na wejœciu 2
DD1
OpóŸnienie do realizacji funkcji alarmu na wej-
œciu 1
DD2
OpóŸnienie do realizacji funkcji alarmu na wej-
œciu 2
IN1-IN2
GND
IN1-IN2
GND
Styki normalnie
zamkniête
(pêtla pr¹dowa)
Styki
normalnie
otwarte
Schemat pod³¹czenia dla wejœæ alarmowych
IN1-IN2
GND
IN1-IN2
GND
Normally
closed contact
Normally
open contact
Connection diagram for the alarm inputs
Direct programming on the SIM card
Contacts
Name Number Description
IN1
0
Alarm activated by connecting input 1 to
ground (GND)
IN2
4
Alarm activated by connecting input 2 to
GND and SMS on input restoring
ID1
10
Input 1 has to be valid for 10 second to
trigger the alarm
ID2
0
Input 2 has to be valid for 0,5 second to
trigger the alarm
DD1
0
Reporting of the alarm on input 1 is
delayed by 0 second
DD2
15
Reporting of the alarm on input 1 is
delayed by 15 seconds
SMS
SIM
Remote programming by SMS
;IN1=0;IN2=4;ID1=10;ID2=0;DD1=0;DD2=15;
Example:
Storage of parameters IN, ID and DD
Table 2. Meaning of the parameters IN, ID and DD
Name
Description
IN1
Operating mode for input 1
IN2
Operating mode for input 2
ID1
Pulse length on input 1
ID2
Pulse length on input 2
DD1
Time delay for alarm acquisition on input 1
DD2
Time delay for alarm acquisition on input 2
Mi 2466
Polski
English
- 25 -
KPx4
KPx5
KPx7 KPx5
KPx7
KPx6
KPx5
KPx4
KPx4
KPx5
KPx8
KPx9
KPx10
KPx11
KPx8 KPx4
KPx9 KPx5
KPx10 KPx6
KPx11 KPx7
KPx7
KPx6
KPx5
KPx4
KPx12 KPx8
KPx13 KPx9
KPx14 KPx10
KPx15 KPx11
KPx5
KPx4
KPx5
KPx6
KPx7
KPx5
KPx8
KPx9
KPx10
KPx11
KPx7 KPx5
KPx12 KPx8
KPx13 KPx9
KPx14 KPx10
KPx15 KPx11
Przyk³ad budowy kaset serii Profilo
Uwaga
Dodatkowe modu³y
PL24S i PL228S
musz¹ byæ
odpowiednio zaprogramowane za pomoc¹ mikroprze³¹-
czników z ty³u urz¹dzenia (patrz instrukcja obs³ugi produ-
któw).
Attention
. The
PL24S
and
PL228S
additional button
modules must be properly programmed through DIP
switches on the back of the devices (see the instructions
provided with the products).
Compositions of the Profilo pushbutton panel
Zale¿noœæ miêdzy przyciskami i grupami po³¹czeñ
Przypisanie przycisków modu³ów PL10G
÷PL124G i grup po-
³¹czeñ jest ustalone i nie mo¿e byæ zmienione przez u¿yt-
kowników (patrz nastêpny rysunek).
Connection between buttons and calling groups
Linking between buttons of modules PL10G÷PL124G and
calling groups is fixed and can not be changed by users
(see next figure)
.
KPx7
KPx6
KPx5
KPx4
KPx7 KPx5
KPx5
KPx4
KPx5
Po³¹czenia do grupy 4
(KPA4, KPB4, KPC4)
Calls the group 4
Po³¹czenia do grupy 5
(KPA5, KPB5, KPC5)
Calls the group 5
Po³¹czenia do grupy 5
(KPA5, KPB5, KPC5)
Calls the group 5
Po³¹czenia do grupy 7
(KPA , KPB7, KPC7)
Calls the group 7
7
Po³¹czenia do grupy 6
(KPA6, KPB6, KPC6)
Calls the group 6
Po³¹czenia do grupy 7
(KPA , KPB7, KPC7)
Calls the group 7
7