Mi 2453 

Gb - 4 -

Display

The display is organized into 3 different areas

-  Status bar
-  Name and address 

of internal users 

and door stations

-  Operating info

Status bar

It is shown in the upper part of the display and gives the 

following info (from left to right)

  

Date

 (day-month-year)

  

Communication status

 (see the following icons)

LED’s

Under the display there are 8 LED’s which indicate some 

important functions of the switchboard.

 

Shows that one or more bookings are present

Shows the presence of a message

Shows that a call is in progress (flashing)

Shows that the ringer tones of the switchboard 

have been excluded (minimum volume)

Shows that the direct call mode of the 

switchboard has been activated

Shows an opened door (if this function has 

been foreseen in the installation)

Shows that the “diverted to a user” operating 

mode of the switchboard has been activated 

(if supported by the software version)

Shows the activation of the internal relay in 

monostable or bistable operating modes

Handset on hook

Handset off hook

Call to or from a user

Communication in progress between switchboard 

operator and user or between two users

Call from door station

Communication in progress between switchboard 

operator and door station or between door station 

and internal user

 

Memory card inserted

 (see the following icons)

 

correctly inserted 

 

Reading error

  

Directory

 (see the following icons)

 Ready 

 Import 

 

directory 

  

 

  Export 

  directory

  

Keypad locked

  

Time

 (hours-minutes) 

Directory 

loading

21.09.11

11.06

Free line

User

name

100

Directory 

sorting

Содержание PDX 2000

Страница 1: ...Mi 2453 SWITCHBOARD A J T G P W D M B K U H Q X E N C L V I R Y S Z F O 1 4 7 2 5 8 0 3 6 9 PDX 2000 Mi 2453 for DUO System ...

Страница 2: ...st be exclusively operated for its intended use The manufacturer cannot be held responsible for possible damage caused by improper erroneous and unreasonable use Keep packing parts away from children i e plastic bags expanded polystyrene etc Do not open the device when it is ON The installation must be made by specialized personnel in compliance with the regulations in force Alwaysrefertospecializ...

Страница 3: ...ll the functions to set and program the switchboard To move inside the submenus use the arrow buttons 7 Arrow up or back Main functions Three operating modes day night and direct call Communication between internal users or internal users and door stations Monitor of one or more door stations Inclusion on a busy user Booking of calls it can store up to 50 unanswered calls Selective door lock relea...

Страница 4: ...de of the switchboard has been activated Shows an opened door if this function has been foreseen in the installation Shows that the diverted to a user operating mode of the switchboard has been activated if supported by the software version Shows the activation of the internal relay in monostable or bistable operating modes Handset on hook Handset off hook Call to or from a user Communicationinpro...

Страница 5: ...witchboard must be programmed with the same address of switchboard according to the previous example 201 for programming please follow the proce dure indicated in the technical manual which comes with the product Program all the door stations to set them for the pres ence of the switchboard Terminal board LI LI Duo line input LO LO Duo line output A A Auxiliary power input 12 15Vdc 0 5A C Common c...

Страница 6: ...wisted cable CAT5 cable 2x1mm AWG17 2x0 32mm AWG22 2x0 2mm AWG24 A D 50 m 164 ft 10 m 33 ft 5 m 17 ft B 150 m 492 ft 150 m 492 ft 150 m 492 ft C 150 m 492 ft 150 m 492 ft 150 m 492 ft E 30 m 98 ft 20 m 65 ft 20 m 65 ft F 150 m 492 ft 50 m 164 ft 35 m 115 ft PA SE PRS210 VD2120 TD2100PL CD213 PL LP LP 2220 230V 230V 127V 127V 0 0 S1 S2 Connection of a local calling button bell function Connecting a...

Страница 7: ...1 1 2 3 4 5 LM LM LO LO LI LI 2221S LP LP PRI 110V 240VAC 2221ML J1 230V 127V 0 LP LP LO LO LI LI PDX2000 A J T G P W D M B K U H Q X E N C L V I R Y S Z F O 1 4 7 2 5 8 0 3 6 9 INTERCOM VIDEOINTERCOM MULTI WAY SYSTEM WITH 1 MAIN DOOR STATION AND A SWITCHBOARD 1 2 termination 47Ω 3 4 termination 70Ω 4 5 termination 100Ω 2 3 open line default 2 3 open line default FP Floor call push button optional...

Страница 8: ...oor station 1 B is equal to the sum of distances B1 B2 and B3 B1 B2 B3 B secondary line a secondary line b L2 L2 230V 127V 0 2273 2273 2221ML SW2 SW2 4 3 2 1 ON 4 3 2 1 ON ON OFF LP LP L1 L1 E DV2420 DV2422A J1 1 2 3 4 5 J1 1 2 3 4 5 LM LM LP LP LD LD PDX2000 A J T G P W D M B K U H Q X E N C L V I R Y S Z F O 1 4 7 2 5 8 0 3 6 9 230V 127V 0 PRS210 LI LI LI LI L1 L1 B LI LI LO LO L2 L2 L1 L1 LP LP...

Страница 9: ...witchboard is locked it is only possible answer to the incoming calls from door stations or internal users In Device Manager menu select keypad lock and press on the display will appear To unlock the keypad press for several seconds the button Ringer tones OFF and ON To set OFF or ON all the ringer tones of the switchboard it is necessary access the menu Device Manager by pressing shortly the butt...

Страница 10: ...station it is necessary to close all the communications in progress Connection of the switchboard to the door sta tions At any moment it is possible to monitor the door stations pressing the button If in the installation there are more door stations pressing the button the switchboard will be connected with the last door station which has made a call For a selective connection with a specific door...

Страница 11: ...his feature can not be guaranteed for all the users To interrupt a communication between to users see chapter Inclusion External to Internal Communication While the switchboard is in communication with a door sta tion it is possible to transfer the call to an internal user for 60 seconds which can be extended following the below procedure press the button door station actually in commu nication wi...

Страница 12: ...correct address press cursor moves to a small box on which there is written the number 0 do not change it only in some specific cases it is possible to change this number press select Save press changing is automatically stored and you will be back to the directory list Delete a user In the directory select the user to be deleted press select delete press with the button select Yes press user is a...

Страница 13: ...erating Mode You access the operating modes of switchboard day or direct calling See enable direct call and back to the operating mode day Settings In this menu it is displayed the list of settings Time Date Language Ringing Tones Ringing Volume Backlighting LCD Contrast and Advanced Settings Time Select Time and press with the keypad enter the actual hour press with the keypad enter the actual mi...

Страница 14: ...C NC NO can be used for additional ringer for the incoming calls a lamp signaller can also be driven power ON a CCTV monitor only during the calls from the door stations bistable relay operated by the button when the relay is activated the LED will light Up monostable relay operated by the button when the relay is activated the LED will light Up timing of relay should be set according the instruct...

Страница 15: ...witchboards at the same hierarchical level it is necessary to set one of them as Mas ter and the others as Slaves for secondary switchboards this setting is required only for those connected to the same secondary line more switchboards connected to a different secondary lines doesn t require to be set as Master and Slave on the contrary all of them must be set as Mas ter From the factory all the s...

Страница 16: ...7 Osimo AN Italy Tel 39 071 7202038 r a Fax 39 071 7202037 e mail info acifarfisa it www acifarfisa it Cod 52704880 Mi 2453 Smaltire il dispositivo secondo quanto prescritto dalle norme per la tutela dell ambiente Dispose of the device in accordance with environmental regulations Écouler le dispositif selon tout ce qu a été prescrit par les règles pour la tutelle du milieu Eliminar el aparato segú...

Отзывы: