FARFISA INTERCOMS PDX 2000 Скачать руководство пользователя страница 14

Mi 2453 

Gb - 14 -

Ringing Volume

Ringing volume is the same for all the kind of calls.

-

 

To adjust it select “Volume” and press 

 - an adjusting bar is displayed on 

the screen - with the buttons 

 or

 adjust the volume  - press 

 

- select “save” - press 

.

Ringing Tones can be disabled choos-

ing the lowest level of volume in this menu or directly from 

the Device Manager menu.

Ringing volume can be also momentarily adjusted acting 

on the buttons 

 or 

 while receiving a call.

Display Backlighting

Select LCD Backlighting - press 

 - 

chose the desired color from the list or 

create a new color - press 

 - select 

“save” - press 

.

Display Contrast

Select LCD Contrast - press 

 - an 

adjusting bar is displayed on the screen, 

adjust the contrast of LCD acting on the 
buttons 

 or 

 - press 

 - 

select “save” - press 

.

 Advanced and System settings

Advanced and system settings are 

fundamental

 for the 

correct working of the system, therefore they are acces-

sible only entering a 4-digit password. From the factory the 

password is 1234

. It is advisable to change it with a per-

sonal one 

(see chapter “Password changing”).

Attention

. It advisable to write down the new password 

and keep it in a safe place; If you lose the password you 

must ask a new one directly to ACI FARFISA.

 

 

Advanced

To access the advanced menu you should:

Press 

 - select “settings” - press 

 - select “advanced” 

- press 

 - enter the 4-digit password - press 

 - the 

following functions will be listed: Password, Relay mode, 

Relay timing, Restore factory settings, Clear all bookings, 

Delete list, Recovery Directory.

Changing Password

To change the password it is necessary: - select “Password” 

– press 

 - press 

 to erase the 

actual password –enter the new 4-digit 

password - press 

 - select “save” 

- press 

New password in now stored.

Operating mode of the internal relay.

Relay inside the switchboard (terminal boards C, NC, NO) 

can be used for:

 additional ringer 

for the incoming calls, a lamp signaller 

can also be driven 

-  

power-ON a CCTV monitor

 only during the calls from the 

door stations 

bistable relay 

operated by the button  ; when the relay 

is activated the LED 

 will light-Up 

-  

monostable relay 

operated by the button  ; when the 

relay is activated the LED 

 will light-Up, timing of relay 

should be set according the instructions of chapter 

“Timing 

of internal relay”.

To set the operating mode it is neces-

sary: - select “Relay mode” - press 

 

- select the requested mode - press 

 

- select “save” - press 

.

Timing of internal relay

To set the activation time of relay, only when the relay op-

erates as 

“additional ringer tone”

 and 

“monostable”

, it 

is necessary: - select “Relay timing” – press 

 - press 

 to erase the previous programmed 

activation time – enter the new activation 

time in seconds (from 1sec to 99 sec.) - 

press 

 - select “save” - press 

.

Factory settings

To restore the factory settings and reset all the data previ-

ously programmed (except the directory) it is necessary:

-select “Restore factory settings” - press 

 - select 

YES

 to confirm or 

NO

 to 

exit - press 

 - select “save” - press 

.

Clear all bookings

To cancel all the booking queue:  

-select “Clear all bookings” – press 

 

- select 

YES

 to confirm or 

NO

 to exit - 

press 

 - select “save” - press 

.

Erasing completely the directory

To completely erase the directory:

-select “Delete list” - press 

 - select 

YES

 to confirm or 

NO

 to exit - press 

 

- select “save” - press 

.

Restoring the users’ in the directory

To restore the last erased directory:

-select “Recovery directory” - press 

 

- select 

YES

 to confirm or 

NO

 to exit - 

press 

 - select “save” - press 

.

Booking

Mode

- Settings

Menu

Programming system

password

1234

- Addit.ringer tone

Monitor door station

Bistable

Relay mode

####

21.09.11

11.06

Display backlight

- Advanced

Display contrast

Settings

Programming relay time

activation

30

Restore factory set.

NO

YES

Clear ALL bookings

NO

YES

Delete list

NO

YES

Recovery directory

NO

YES

Ringer tones volume

75%

- Red

Green

Blue

Display backlight

Display contrast

50%

Содержание PDX 2000

Страница 1: ...Mi 2453 SWITCHBOARD A J T G P W D M B K U H Q X E N C L V I R Y S Z F O 1 4 7 2 5 8 0 3 6 9 PDX 2000 Mi 2453 for DUO System ...

Страница 2: ...st be exclusively operated for its intended use The manufacturer cannot be held responsible for possible damage caused by improper erroneous and unreasonable use Keep packing parts away from children i e plastic bags expanded polystyrene etc Do not open the device when it is ON The installation must be made by specialized personnel in compliance with the regulations in force Alwaysrefertospecializ...

Страница 3: ...ll the functions to set and program the switchboard To move inside the submenus use the arrow buttons 7 Arrow up or back Main functions Three operating modes day night and direct call Communication between internal users or internal users and door stations Monitor of one or more door stations Inclusion on a busy user Booking of calls it can store up to 50 unanswered calls Selective door lock relea...

Страница 4: ...de of the switchboard has been activated Shows an opened door if this function has been foreseen in the installation Shows that the diverted to a user operating mode of the switchboard has been activated if supported by the software version Shows the activation of the internal relay in monostable or bistable operating modes Handset on hook Handset off hook Call to or from a user Communicationinpro...

Страница 5: ...witchboard must be programmed with the same address of switchboard according to the previous example 201 for programming please follow the proce dure indicated in the technical manual which comes with the product Program all the door stations to set them for the pres ence of the switchboard Terminal board LI LI Duo line input LO LO Duo line output A A Auxiliary power input 12 15Vdc 0 5A C Common c...

Страница 6: ...wisted cable CAT5 cable 2x1mm AWG17 2x0 32mm AWG22 2x0 2mm AWG24 A D 50 m 164 ft 10 m 33 ft 5 m 17 ft B 150 m 492 ft 150 m 492 ft 150 m 492 ft C 150 m 492 ft 150 m 492 ft 150 m 492 ft E 30 m 98 ft 20 m 65 ft 20 m 65 ft F 150 m 492 ft 50 m 164 ft 35 m 115 ft PA SE PRS210 VD2120 TD2100PL CD213 PL LP LP 2220 230V 230V 127V 127V 0 0 S1 S2 Connection of a local calling button bell function Connecting a...

Страница 7: ...1 1 2 3 4 5 LM LM LO LO LI LI 2221S LP LP PRI 110V 240VAC 2221ML J1 230V 127V 0 LP LP LO LO LI LI PDX2000 A J T G P W D M B K U H Q X E N C L V I R Y S Z F O 1 4 7 2 5 8 0 3 6 9 INTERCOM VIDEOINTERCOM MULTI WAY SYSTEM WITH 1 MAIN DOOR STATION AND A SWITCHBOARD 1 2 termination 47Ω 3 4 termination 70Ω 4 5 termination 100Ω 2 3 open line default 2 3 open line default FP Floor call push button optional...

Страница 8: ...oor station 1 B is equal to the sum of distances B1 B2 and B3 B1 B2 B3 B secondary line a secondary line b L2 L2 230V 127V 0 2273 2273 2221ML SW2 SW2 4 3 2 1 ON 4 3 2 1 ON ON OFF LP LP L1 L1 E DV2420 DV2422A J1 1 2 3 4 5 J1 1 2 3 4 5 LM LM LP LP LD LD PDX2000 A J T G P W D M B K U H Q X E N C L V I R Y S Z F O 1 4 7 2 5 8 0 3 6 9 230V 127V 0 PRS210 LI LI LI LI L1 L1 B LI LI LO LO L2 L2 L1 L1 LP LP...

Страница 9: ...witchboard is locked it is only possible answer to the incoming calls from door stations or internal users In Device Manager menu select keypad lock and press on the display will appear To unlock the keypad press for several seconds the button Ringer tones OFF and ON To set OFF or ON all the ringer tones of the switchboard it is necessary access the menu Device Manager by pressing shortly the butt...

Страница 10: ...station it is necessary to close all the communications in progress Connection of the switchboard to the door sta tions At any moment it is possible to monitor the door stations pressing the button If in the installation there are more door stations pressing the button the switchboard will be connected with the last door station which has made a call For a selective connection with a specific door...

Страница 11: ...his feature can not be guaranteed for all the users To interrupt a communication between to users see chapter Inclusion External to Internal Communication While the switchboard is in communication with a door sta tion it is possible to transfer the call to an internal user for 60 seconds which can be extended following the below procedure press the button door station actually in commu nication wi...

Страница 12: ...correct address press cursor moves to a small box on which there is written the number 0 do not change it only in some specific cases it is possible to change this number press select Save press changing is automatically stored and you will be back to the directory list Delete a user In the directory select the user to be deleted press select delete press with the button select Yes press user is a...

Страница 13: ...erating Mode You access the operating modes of switchboard day or direct calling See enable direct call and back to the operating mode day Settings In this menu it is displayed the list of settings Time Date Language Ringing Tones Ringing Volume Backlighting LCD Contrast and Advanced Settings Time Select Time and press with the keypad enter the actual hour press with the keypad enter the actual mi...

Страница 14: ...C NC NO can be used for additional ringer for the incoming calls a lamp signaller can also be driven power ON a CCTV monitor only during the calls from the door stations bistable relay operated by the button when the relay is activated the LED will light Up monostable relay operated by the button when the relay is activated the LED will light Up timing of relay should be set according the instruct...

Страница 15: ...witchboards at the same hierarchical level it is necessary to set one of them as Mas ter and the others as Slaves for secondary switchboards this setting is required only for those connected to the same secondary line more switchboards connected to a different secondary lines doesn t require to be set as Master and Slave on the contrary all of them must be set as Mas ter From the factory all the s...

Страница 16: ...7 Osimo AN Italy Tel 39 071 7202038 r a Fax 39 071 7202037 e mail info acifarfisa it www acifarfisa it Cod 52704880 Mi 2453 Smaltire il dispositivo secondo quanto prescritto dalle norme per la tutela dell ambiente Dispose of the device in accordance with environmental regulations Écouler le dispositif selon tout ce qu a été prescrit par les règles pour la tutelle du milieu Eliminar el aparato segú...

Отзывы: