USE AND MAINTENANCE MANUAL - SECTION 3
AERIAL PLATFORM ELEVAH 70 - Rev. 04_2020
Page 3-2
FUNCTIONAL TEST
At the end of the "DAILY INSPECTION" (section n°6), carry out a functional test of all plants in an
area free from overhead obstacles and at ground level.
ATTENTION
IF THE MACHINE DOES NOT WORK PROPERLY, SWITCH IT OFF IMMEDIATELY. WARN
MAINTENANCE PERSONNEL OF THE PROBLEM. DO NOT USE THE MACHINE UNTIL IT IS
DECLARED SAFE TO USE.
Carry out a functional test as detailed below.
1. Carry out the operations as instructed, from the ground controls, without any load in the
cage.
a. Ensure all machine functions are disabled when activating (pressing) the emergency stop
button;
b. Check the correct operation of the manual descent valve.
2. From the control console of the cage, carry out the detailed operations.
a. Ensure the control console is correctly assembled and securely fastened;
b. Lift and lower the work platform checking that lifting and lowering happen regularly;
c. Ensure all machine functions are disabled when activating (pressing) the emergency stop
button.