background image

7

MANUAL ON 

(“AUTO” led OFF and “CONTACT STATUS” led ON)

In  this  operating  mode,  the  receiver  relay  contact  is  always  closed  and  the 

radio transmission implemented by the transmitter module is ignored (conse-

quently chronothermostat / thermostat commands are not accepted).

MANUALE OFF

(“AUTO” led OFF and “CONTACT STATUS” led OFF)

In this operating mode, the receiver relay contact is always open and the radio 

transmission implemented by the transmitter module is ignored (consequently 

chronothermostat / thermostat commands are not accepted).

SYSTEM CODE SELF-LEARNING PROCEDURE

Before  using  the  CH170D  actuator  in AUTOMATIC  mode  its  code  shall  be 

memorised into the Fantini Cosmi transmitter you purchased. To prevent stor-

ing of a different code, during the configuration procedure the reception sen

-

sitivity is reduced and therefore the distance between transmitter and receiver 

shall be 2 m max. Proceed as follows:

1. Turn the receiver on and then keep the button pressed until selecting the 

AUTOMATIC MODE (see paragraph “OPERATION”).

2. Keep the button pressed for over 10 seconds to start the “SELF-LEARNING” 

procedure, the “AUTO” led will start flashing.

3. Force radio thermostat / chronothermostat transmission (refer to the relevant 

user’s guide).

4. Carry out the OPERATION CHECK procedure to check for correct configu

-

ration of the programmed receiver.

N.B.: 

Max. 45 seconds shall pass between step 2 and step 3 of the above 

procedure.

Receiver “POWER ON” led will turn red if over two minutes pass without re-

ceiving data.

OPERATION CHECK

To  use  the  chronothermostat/  thermostat  refer  to  the  relevant  instruction 

manuals.

-Make  sure  the  receiver  is  in  AUTOMATIC  mode  (see  paragraph  OPERA-

TION).

-Wait  for  chronothermostat/  thermostat  data  transmission  and  then  check 

whether CH170D relay status matches with chronothermostat/ thermostat.

- Switch over chronothermostat/ thermostat and check whether the CH170D 

relay status changes.

Should the “POWER ON” led be red then transmitter and receiver are too dis-

tant: communication between the two devices is null or unreliable.

Содержание CH170D

Страница 1: ...vironmental conditions Do not shield the device with metallic parts Connect cables to the base terminal board according to the wiring diagrams shown Receiver power supply 230 V a c shall be connected to terminals N and L whereas the user pump burner zone valve humidistat etc shall be connected to terminals 1 and 2 N B Several receivers can be connected to one transmitter OPERATION The receiving de...

Страница 2: ...perating mode the receiver receives a radio signal coded by the chron othermostat via the transmitter interface and triggers the integral relay The POWER ON led takes on a different colour according to the quality of the signal received RED signal absent or very disturbed ORANGE satisfactory reception GREEN good reception Fast and brief led flashing indicates the reception of radio data sent by th...

Страница 3: ...ceiver on and then keep the button pressed until selecting the AUTOMATIC MODE see paragraph OPERATION 2 Keep the button pressed for over 10 seconds to start the SELF LEARNING procedure the AUTO led will start flashing 3 Force radio thermostat chronothermostat transmission refer to the relevant user s guide 4 Carry out the OPERATION CHECK procedure to check for correct configu ration of the program...

Страница 4: ... EN60730 1 EN 301 489 3 EN 300 220 3 Power supply 230V 50 Hz Container IP20 Absorbed power 2VA Relay output 5 3 A 250 V Switching contacts voltage free Receiver OOK868 350 MHz Sensitivity 104 dBm Container dimensions 3 modules 17 5 mm per rail EN50022 Degree of pollution 2 Software class A Double insulation Disconnection 1B type Installation type back panel mounting Impulse voltage 4000V 10 sec 23...

Отзывы: