APPLICATION AND USE

CH170D is a radio receiver (actuator) that coupled to a transmitter of the Fan-

tini  Cosmi  product  line  enables  to  remotely  control  a  preset  user  (usually  a 

boiler).

Sent radio signal is free from interference with other device even if the same 

frequency is used.

INSTALLATION AND CONNECTIONS

Installation shall be performed according to current CEI Standards.

The distance between actuator and transmitter must not exceed 30 m in closed 

spaces and 70 m in open spaces (N.B. Range data could vary according to 

environmental conditions). Do not shield the device with metallic parts.

Connect cables to the base terminal board according to the wiring diagrams 

shown. Receiver power supply (230 V a.c.) shall be connected to terminals N 

and L whereas the user (pump, burner, zone valve, humidistat, etc.) shall be 

connected to terminals 1 and 2.

N.B. Several receivers can be connected to one transmitter.

OPERATION

The receiving device features three leds giving the following indications:

 

POWER  ON

:  when this led is on it indicates that the receiver is properly 

powered. The meaning of the different colours of this led is specified below.

AUTO: when this led is on it indicates that the receiver is configured in AUTO

-

MATIC MODE. When the led is off the MANUAL MODE is active.

 

 CONTACT STATUS

: when this led is on it indicates that the relay contact 

is closed, otherwise (led off) it will be open.

CH170D RADIO ACTUATOR FOR DIN RAIL MOUNTING

Содержание CH170D

Страница 1: ...vironmental conditions Do not shield the device with metallic parts Connect cables to the base terminal board according to the wiring diagrams shown Receiver power supply 230 V a c shall be connected to terminals N and L whereas the user pump burner zone valve humidistat etc shall be connected to terminals 1 and 2 N B Several receivers can be connected to one transmitter OPERATION The receiving de...

Страница 2: ...perating mode the receiver receives a radio signal coded by the chron othermostat via the transmitter interface and triggers the integral relay The POWER ON led takes on a different colour according to the quality of the signal received RED signal absent or very disturbed ORANGE satisfactory reception GREEN good reception Fast and brief led flashing indicates the reception of radio data sent by th...

Страница 3: ...ceiver on and then keep the button pressed until selecting the AUTOMATIC MODE see paragraph OPERATION 2 Keep the button pressed for over 10 seconds to start the SELF LEARNING procedure the AUTO led will start flashing 3 Force radio thermostat chronothermostat transmission refer to the relevant user s guide 4 Carry out the OPERATION CHECK procedure to check for correct configu ration of the program...

Страница 4: ... EN60730 1 EN 301 489 3 EN 300 220 3 Power supply 230V 50 Hz Container IP20 Absorbed power 2VA Relay output 5 3 A 250 V Switching contacts voltage free Receiver OOK868 350 MHz Sensitivity 104 dBm Container dimensions 3 modules 17 5 mm per rail EN50022 Degree of pollution 2 Software class A Double insulation Disconnection 1B type Installation type back panel mounting Impulse voltage 4000V 10 sec 23...

Отзывы: