22
In-
dex
Parameter
Writing
Values
Preset
value
1
Type of connected
card
COn
rEL / rAd / --- none
2
Temperature scale CELS o
FHAr
°C / °F
°C
3
Type of regulation Std
o
ProP
Std / ProP
Std
3A
Thermal
differential
DIFF
HI / LO
LO
3A
Regulation band
BAnd
1 °C – 4 °C
(step 0.1°C)
2 °C
3B
Regulation period Per
5 / 10 / 20
minutes
10
minutes
4
Separate
temperature probe
con
fi
guration
Sect
--- / FLO / In
/ Out
---
4A
Floor temperature
limit
T
fl
o
15 °C –
45 °C
27.0 °C
5
Ambient
temperature
correction
Corr
-4.0 °C
to +4.0 °C
0.0 °C
6
Optimization
Opt
ON/OFF
OFF
6A
Max. optimization
duration (hours)
OPtH
1h – 5h
2h
7
Pump anti-seizure Pu
ON/OFF
OFF
In-
dex
Parameter
Writing
Values
Preset
value
8
Low
battery
bAtt
--- / On /
OFF
OFF
9
Software release
SOFt
xxx
xxx
Type of connected card
The chronothermostat can check whether the
base is connected. If it is not connected dash-
es will be displayed whereas when it is con-
nected the writing rEL is displayed. Writing rAd
is displayed in radiofrequency versions.
Temperature scale
To select the temperature scale to be dis-
played: Celsius (centigrade) or Fahrenheit.
When choosing the Fahrenheit scale, temper-
atures may range between 0.0 and 99.9 °F.
Type of regulation
To select the temperature regulation mode:
differential (Std) or proportional (ProP). This
parameter is used for heating only.
Thermal differential
To set the thermal differential value to be used