Decimal
Flag
128
Light Sensor
64
Humidity Sensor
32
Temperature Sensor
16
Ultraviolet Sensor
1
Battery Sensor
15
minimum sensitivity level. If set it to 0, the motion sensor will be disabled.
Monitoring temperature, humidity, luminance and ultraviolet.
Your MultiSensor can report temperature, humidity, luminancen and
ultraviolet across a Z-Wave network when requested. If this function is
supported by a controller, generally a gateway, the data will be displayed
within its interface. The specific Z-Wave commands for the support of
monitoring is the Multilevel Sensor Command Class. Automatic reports
are sent to association group 1, which is setup via the Association
Command Class. Please consult the controller’s operation manual for
specific instructions on setting your MultiSensor.
Setting automatic report flags.
Parameter 101-103 [4 byte dec] can be configured through your
gateway in case the default settings of your MultiSensor are not what
you desire.
The table above shows a decimal representation of all flags that can
be set on parameter 101-103 to report specific data.