7.

Cut off excess lead wire approximately 6 to 9

inches above top of the top of the downrod. Strip

insulation off 1/2-inch from the end of each lead

wire (Figure 7).

How to Assemble Your Ceiling Fan (continued)

How to Hang Your Ceiling Fan

Figure 7

NOTE:

All set screws must be checked, and retightened

where necessary, before installation.

NOTE: If you are not sure if the outlet box is grounded, 
contact a licensed electrician for advise, as it must be 
grounded for safe operation.

WARNING

The fan must be hung with at least 7’ of clearance 
from 

ƀ

oor to blades. (Figure 2)

WARNING

To avoid possible 

ſ

re or shock, be sure electricity is 

turned off at the main fuse box before hanging. 
(Figure 1)

1. Securely attach the hanger bracket to the outlet box 
using the outlet box screws and washers supplied with 
the outlet box. (Figure 2)

2. Drill a ¼” pilot hole into the building structure to 
prevent splitting or cracking with installation of the lag 
bolt. Using the  ” x 2” lag bolt and 

flat

 washer, attach 

safety cable to ceiling joist or wood structural member. 
The lag bolt will pass through the 

flat

 washer, safety 

cable loop, and into the building structure. (Figure 3)

NOTE: Ceiling support cable cannot be secured to 
junction box only, it must be directly secured to ceiling 
joist or structural member using the  ” x 2” lag bolt 

CPFƀCVYCUJGT(KIWTG

3. Make sure the electrical supply wires, including 
the hanger bracket grounding wire and safety cable 
are pulled through the downrod, between the hanger 
bracket and the junction box so that electrical

 

 

 

 

 

 

 

connections can be made later.

Figure 2

CEILING

FLOOR

NO LESS 

THAN 

7 FEET

Figure 1

MAIN FUSE BOX

WOOD MEMBER

(2” X 4” APPROX.)

CEILING JOIST

CEILING

JUNCTION 

BOX

HANGER BRACKET

C E I L I N G 

SUPPORT 

CABLE

Figure 3

WARNING

The  outlet  box  must  be  securely  anchored.  Hanger 
bracket must seat 

ſ

rmly against outlet box. If the 

outlet box is recessed, remove wall board until bracket 
contacts box. If bracket and /or outlet box are not
securely attached, the fan could wobble or fall.

Содержание FPD7943

Страница 1: ...Model No FPD7943 OWNER S MANUAL READ AND SAVE THESE INSTRUCTIONS The Jennix Ceiling Fan Net Weight 24 68lbs 11 21 kg...

Страница 2: ...from the original purchase due to defects in materials or workmanship labor to repair the motor will be provided free of charge at our national service center Purchaser will be responsible for labor c...

Страница 3: ...n conjunction with product use or performance except as may otherwise be accorded by law This warranty gives you special legal rights and you may also have other rights that vary from state to state 1...

Страница 4: ...t by Fanimation Substitution of parts or accessories not designated for use with this product by Fanimation could result in personal injury or property damage Contact your retail store for missing or...

Страница 5: ...energy and dollar savings could be realized with this simple step Electrical and Structural Requirements If your fan is to replace an existing light fixture turn electricity off at the main fuse box a...

Страница 6: ...as follows Route the three 80 inch wires through the hanger ball Position the pin through the two holes in the downrod and align the hanger ball so the pin is captured in the groove in the top of the...

Страница 7: ...tting or cracking with installation of the lag bolt Using the x 2 lag bolt and flat washer attach safety cable to ceiling joist or wood structural member The lag bolt will pass through the flat washer...

Страница 8: ...re 1 WARNING MAIN FUSE BOX Figure 1 NOTE If you are not sure if the outlet box is grounded contact a licensed electrician for advice as it must be grounded for safe operation Figure 2 1 Connect the gr...

Страница 9: ...t utilizing the keyslot twist lock feature Figure 2 How to Install Your Canopy Housing To avoid possible fire or shock make sure that the electrical wires are completely inside the canopy housing and...

Страница 10: ...he two key slots Replace the third screw and securely tighten all three screws Figure 2 3 Connect the 2 single pin connector from the light socket plate to 2 single pin connector from motor assembly F...

Страница 11: ...es before relamping Bulb is pressurized and may shatter DO NOT TOUCH BULB WITH BARE HANDS Fingerprints may result in shorter bulb life Remove fingerprints with alcohol prior to use 6 Secure the glass...

Страница 12: ...o control light Infinite light levels are available by holding the light on off button Figure 4 Light button Fan speed NOTE Receiver in controllers system features an automatic learning function There...

Страница 13: ...nd is to be used with CFL bulbs as CFL bulbs cannot be dimmed The receiver provides the following protective function Figure 5 Lock position The DC motor has a built in safety feature against blade ob...

Страница 14: ...tate variable speed controls Solid state controls are not recommended choose an alternative control method 6 Tighten screws securely 1 Blades not attached to fan 2 Loose screws in motor housing 3 Scre...

Страница 15: ...Glass 10 14 11 TR29 Hand Held Remote Control 12 Lower Steel Cap Assembly 13 HDWFP7943 Wire Connector 4 Bag Assembly Loose Parts 4 Phillips Head Screwdrive Pan Head Screw 1 4 20 x 14mm 7 Bag Assembly S...

Страница 16: ...16 1 2 3 4 6 7 8 9 5 14 12 11 10 13 NOTE The illustration shown is not to scale or its actual configurations may vary FPD7943 Exploded View...

Страница 17: ...Copyright 2012 2012 07 V 01 10983 Bennett Parkway Zionsville IN 46077 Toll Free 888 567 2055 FAX 866 482 5215 Outside U S call 317 733 4113 Visit Our Fanimation Website www fanimation com...

Страница 18: ...Ventilador de techo Modelo N FP7943 MANUAL DEL PROPIETARIO LEA Y GUARDE ESTAS INSTRUCCIONES Peso neto 24 68 lb 11 21 kg The Jennix...

Страница 19: ...ncuentra en funcionamiento 4 Instrucciones de seguridad adicionales Para evitar posibles descargas el ctricas aseg rese de que la electricidad est desconectada en la caja de fusibles antes de realizar...

Страница 20: ...sible que tambi n goce de otros derechos que pueden variar seg n el estado Es normal que se produzca un cierto movimiento oscilante y esto no debe considerarse un problema o defecto 10 GARANT A LIMITA...

Страница 21: ...s de 15 2 a 30 5 m 50 a 100 pies NOTA Si no est seguro de la descripci n de una pieza consulte la ilustraci n del despiece 1 Veri que que haya recibido las siguientes piezas ADVERTENCIA No instale ni...

Страница 22: ...el reloj Esto produce una suave corriente ascendente que obliga al aire c lido que se acumula cerca del techo a bajar al espacio ocupado No olvide ajustar el termostato cuando utilice el ventilador de...

Страница 23: ...rav s de los dos orificios en el barral y alinee la semiesfera de modo que el pasador quede atrapado en la ranura de la parte superior de la misma Empuje la semiesfera hacia arriba bien ajustada contr...

Страница 24: ...a de salida tiene conexi n a tierra pida consejo a un electricista certificado ya que debe tener conexi n a tierra para un funcionamiento seguro 1 Fije bien la abrazadera para colgar a la caja de sali...

Страница 25: ...e debe tener conexi n a tierra para un funcionamiento seguro Para evitar una posible descarga el ctrica aseg rese de cortar la alimentaci n el ctrica de la caja de fusibles principal antes de colgar e...

Страница 26: ...e los cables el ctricos se encuentren completamente adentro de la cubierta del capuch n y de que no est n aprisionados entre la cubierta y el tec ADVERTENCIA C mo realizar la instalaci n el ctrica del...

Страница 27: ...ad del motor Figura 3 PRECAUCI N A fin de reducir el riesgo descargas el ctricas desconecte el circuito de suministro el ctrico al ventilador antes de instalar el kit de iluminaci n x 6 1 4 20 x 14 mm...

Страница 28: ...lla La bombilla est presurizada y puede hacerse a icos NO TOQUE LA BOMBILA CON LAS MANOS SIN PROTECCI N Las huellas dactilares pueden disminuir la vida til de la bombilla Elimine las huellas dactilare...

Страница 29: ...ura 2 Para que el ventilador sea functional instale las pilas incluidas de 23A 12V en el transmisor del mando a distancia Mientras el ventilador est apagado A continuaci n siga el proceso de fijaci n...

Страница 30: ...para evitar la obstrucci n de las palas durante el funcionamiento del ventilador Si algo obstruyera las palas del ventilador el motor dejar a de funcionar tas 30 segundos de interrupci n Extraiga los...

Страница 31: ...co mantenimiento necesario para el ventilador de techo es una limpieza peri dica Al llevar a cabo la limpieza use s lo un cepillo suave o un pa o sin pelusas para evitar rayar el acabado No se requier...

Страница 32: ...suministro principal de electricidad est desconectado 5 Algunos motores de ventilador son sensibles a las se ales de los controles de velocidad de estado s lido variables Los controles de estado s lid...

Страница 33: ...de uni n del motor Unidad del motor del ventilador Antes de desechar los materiales de embalaje aseg rese de haber extra do todas las piezas Inserte los C DIGOS DE ACABADO consulte el n mero de modelo...

Страница 34: ...34 FPD7943 NOTA Despiece 1 2 3 4 6 7 8 9 5 14 12 11 10 13...

Страница 35: ...12 Fanimation 2012 07 V 01 10983 Bennett Parkway Zionsville IN 46077 Llame Sin Cargo al 888 567 2055 FAX 866 482 5215 Desde fuera de los EE UU llame al 317 733 4113 Visite nuestro sitio Web en www fan...

Отзывы: