background image

IntelliTek

 

Functions and Screen layout 

 

 

 

 

 

1. 

Network

: Indicates how the IntelliTek was configured (can only be changed by rebooting). 

 

 

Standalone

: the IntelliTek is running without a network. 

 

 

Network

: the IntelliTek is running within a network and is connected to a server. 

2. 

Type of Barn / Feeding-device: 

Indicates for which “type of barn” / “Feeding-device” this TouchTek Box is 

configured (can only be changed by rebooting).

 

 

3. 

Date / time

: Readout of current the date and time. If the IntelliTek is connected to the network, the date and 

time are set on the TouchTek server and synchronized with all the TouchTek Boxes in the network. 

4. 

Language-button

: At the language-button the user can switch-over between two pre-selected languages. 

The two wanted languages can be nominated at the PC. 

5. 

Sows in section

: Shows how many sows are registered at this section (the section-number is shown at the 

header). After clicking, a list of all sows with information about every individual animal is displayed (animal 
list). 

6. 

Sows haven’t eaten yet

: Shows how many sows haven’t already eaten enough in the current feeding-period 

(the header shows the reaming time of the actual feeding period). The user can click on this field to get a list 
of these sows w

ith more detailed information’s. 

7. 

Sows on alarmlist

: Shows the sows on the alarmlist that haven’t eaten enough at current and last feeding 

period. The user can click on this field to get the alarmlist with more detailed informations (e.G. Alarm-day). 

 

The user has to take action if sows are on the alarmlist in order to avoid damage of the sows! (see 
manual system-overview). 

8. 

Stadium of the sows

: Provides information’s about the “stadium” of the sows at this section. The view of this 

field depends on the 

setting “stadium” at this TouchTek Box (“individual – dynamic group” or “section wide – 

static group”) -> see chapter settings of this manual. 

 

If the “stadium” of the TouchTek Box is configured as “individual – dynamic group” the Field shows the 
lowest and the highest stadium-day of the sows within this section. The user cannot click on this field! 

 

If the “stadium” of the TouchTek Box is configured as “section wide – static group” the filed shows the 
stadium and stadium-day of the sows within this section (all sows within this section have the same 
stadium and stadium-day!). The user can click on this field to set the stadium and stadium-day to a 
different value! 

9. 

Calculated feed-amounts of the sows

: Provides information’s about the “actual feed-amounts” of the sows 

in the current feed-period. The field shows the lowest and the highest feed-amount calculated based on the 
assigned feed-

profiles. The view of this field depends on the setting “Feed profiles” at this TouchTek Box 

(“individual ” or “section wide” ) -> see chapter settings of this manual. 

 

If the “Feedprofile” of the TouchTek Box is configured as “individual ” the user can click on this field to get 
an overview how many sows are assigned to what feed-profile. Also he can adjust the settings of feed-
pr

ofile “0: Standard”   

 

If the “Feedprofile” of the TouchTek Box is configured as “section wide ” the header shows the feed-
profile that is assigned to all sows within this section. The user can click on this field to assign a different 
feed-profile to all sows. Also he can adjust the settings of feed-

profile “0: Standard”   

10. 

Working-plan or selection-pen

: The filed shown at this spot depends on the version of the connected 

IntelliTekstations. If the IntelliTek stations are equipped with a SelTek selection gate, the filed “selection-pen” 
is shown; otherwise the field “actions” is shown.   

 

Action

: The field shows the number of sows with scheduled actions during the current feeding period. 

The user can click on this field to get a list of these sows with more detailed information’s about the 
reason for the action and if the action is already executed. 

 

 

Содержание INTELLITEK

Страница 1: ...g...

Страница 2: ...d by Fancom For the latest information about product installation and operation please contact the customer service dept and or the technical service dept of the Fancom company concerned In spite of t...

Страница 3: ...uchTek Box as section wide feed profiles 10 4 Daily management 11 4 1 Register sows to the TouchTek Box 11 4 2 Add anonym sows at the TouchTek Box 11 4 3 Unregister sows from the TouchTek Box section...

Страница 4: ...for the end users The following symbols are used in this manual Tips and suggestions Note providing recommendations and additional information Warning indicating damage to the product if you do not f...

Страница 5: ...ng the modus of the IntelliTek station standard open training Activating actions ColorTek DryTek that will be applied to all sows within that section Showing device alarm messages Configure the settin...

Страница 6: ...ide static group see chapter settings of this manual If the stadium of the TouchTek Box is configured as individual dynamic group the Field shows the lowest and the highest stadium day of the sows wit...

Страница 7: ...have left the selection pen So the number shown at the TouchTek Box always has to reflect the real number of sows in the selection pen If the real number of sows in the selection pen is higher than re...

Страница 8: ...by the user at the TouchTek Box 1 Calibrate the dispensers of this section individually 2 Is the section for a dynamic or static group of sows 3 Will all sows of this section have the same feed profi...

Страница 9: ...is switched OFF the system values will be applied for this section The user can set individual values for the DosTek Dispensers of this section by switching ON the user values and set them accordingl...

Страница 10: ...ily that this stadium was assigned to the sow automatically by the system not manually and needs to be checked corrected Example 1 The user knows that in this section are only pregnant sows never empt...

Страница 11: ...if a sow is moved new to the gestation area but not if a sow is relocated from one gestation section to another gestation section That means for example if a sow is relocated from the location gestati...

Страница 12: ...ek Box as section wide feed profile to easily choose the wanted feed profile at the TouchTek Box what is valid for all sows within this section In order to provide all sows with their specific individ...

Страница 13: ...ek Box is configured as section wide feeding the user can set the feed profile for all sows within this section direct at the TouchTek start screen No other settings are needed If the user sets the fe...

Страница 14: ...not shown at the alarmlist If the user wants to put sows into the section without register them by the PC or MILAN Touch Handheld he can add the number of sows he put into the section at the TouchTek...

Страница 15: ...aten yet or Sows on alarmlist It appears a sow list with a button Remove sow in every line 2 Search within the sow list for the sow you want to remove and click Remove sow to remove an individual sow...

Страница 16: ...a sow from the TouchTek Box When a sow is unregistered from the TouchTek Box she must physically be removed from the section No alarm message will be generated for this sow in the future anymore Ignor...

Страница 17: ...ay By changing the stadium day the header shows the corresponding Insemination date or feed date if stadium empty 3 Click Save to confirm or Cancel to refuse The stadium and stadium day of all sows at...

Страница 18: ...uttons will be shown after selecting the feed profile 0 Standard This functionality exists only if the IntelliTek stations at this TouchTek Box are equipped with SelTek selection gates With this funct...

Страница 19: ...what can result in injured or dead pigs This functionality exists only if the IntelliTek stations at this TouchTek Box are not equipped with SelTek selection gates The working plan is a list of sows t...

Страница 20: ...filled with the wanted substance All sows at this section visiting the IntelliTek station after the DryTek dispenser is switched ON will be immediately provided with the dry substance until the DryTe...

Страница 21: ...rkers are filled with the wanted color All sows at this section visiting the IntelliTek station after the ColorTek marker is switched ON will be immediately color marked until the ColorTek marker is s...

Страница 22: ...ic code of the error that occurs that s helps service for troubleshooting Message Text that explaining the alarm regarding what happened where Date Time Point of time the error occurs Device messages...

Отзывы: