PART 2: MOTOR INSTALLATION GUIDE

IN ROOF SOLUTION

Positioning your In-Roof Unit:

It is recommended that the In-Roof motor unit be mounted in a roof space or 
wall cavity. Please ensure that the In-Roof motor unit is positioned in an environ-
ment that is free of other gases to enable an effi  cient expulsion of the cooking 
by-products and to ensure that back draft of external gases doesn’t take place.
Please ensure the motor is positioned away from other exhausts such as replace 
chimneys, gas fuses, etc. The in roof unit can be mounted so that it ducts directly 
through the wall or eave.

STEP 1:

Establish a suitable position in the roof or wall cavity for the In-Roof motor unit, 
ensuring that the distance between the Roof motor unit and the outside vent is 
under 800 mm. The In-Roof motor unit must be located a minimum of 3 metres 
from the hood unit.

STEP 2:

Using the mounting bracket and screws, mount the In-roof motor unit to a 
beam, truss or another appropriate structures in the roof or wall space. Ensure 
the direction of airfl ow is toward the outside. The direction of airfl ow is marked 
on the In-roof motor unit.

STEP 3:

Cut a 205 mm diameter hole in the wall or eave to enable the mounting of the 
external vent. Please ensure that the hole is cut in a practical position to enable 
the Flexi Duct to be secured. Attach the Flexi Duct to the vent and then mount 
vent to the wall or eave.

STEP 4:

Attach the Flexi Duct from the external vent to the outlet of the In-roof motor 
unit using duct clamps. To minimise ineffi  ciencies and noise ensure the duct is 
pulled tight.

STEP 5:

Attach Flexi Duct from the In-roof motor unit to the rangehood using duct 
clamps. Ensure that the duct is pulled tightly to ensure that FlexiDuct remains 
fi rm and stable during operation. Avoid sharp bends in the duct. Gentle bends 
in the ducting are recommended as it assists in muffl  ing noise from the fan unit 
back to the rangehood. If the FlexiDuct needs to be extended attach the two 
FlexiDuct ends using a RigidDuct insert, secured by pipe clamps or duct tape.

STEP 6:

Attach the male plug of the In-roof motor unit to the female plug of the range-
hood to enable power supply to the fan motor unit.
An extension lead (not supplied) of up to fi ve meters may be added if required.

EXTERNAL ROOF SOLUTION - METAL ROOF INSTALLATION

Inspection:

Ensure the unit has arrived in good condition and that the impeller will spin 
freely.
This product is designed to be installed on a roof up to 45° pitch.

1. Installation of this product should be carried out by appropriately qualifi ed 

persons.

2. Cut a hole in the roof 200 mm minimum (with regard to roof pitch angle) 

diameter. The hole should be positioned adjacent to a rafter or other member 
to facilitate the use of the mounting brackets (optional accessory). Ensure a 
clean edge.

3. Cut a 190 mm diameter hole in the rubber roof fl ashing (optional accessory) 

for fi tting over the rigid duct.

4.  Slide the fl ashing over the rigid duct to the required position.
5.  Check the fi t of the duct in the cut hole. The duct must be positioned vertical-

ly.

6. If satisfactory fasten the duct to the rafter or other support using the mount-

ing brackets (optional accessory).

7.  Fit the fl ashing to the metal deck using suitable mounting screws.
8. Attach the fl exi duct leading from the rangehood to the bottom of the rigid 

duct using the supplied duct clamps.

9. Connect the male power plug to the female plug connected to the range-

hood. An extension lead (purchased separately ) can be used if necessary if 
the duct run has been extended.

Safety Considerations:

1.  All connections must be in accordance with any local regulations.
2. Fans have automatic thermal cut out switches incorporated in the motor as 

standard.

3. This product is not intended for use by persons (including children) with re-

duced sensory or mental capabilities, or lack of experience and knowledge, 
unless they have been given supervision or instruction concerning use of the 
product by a person responsible for their safety. Children should be supervi-
sed to ensure that they do not play with the product.

4.  For duct or partition mount, precautions must be taken to avoid the back-fl ow 

of gases into the room from the open fl ue of gas or other open-fi re appliances.

5. If the supply cord is damaged it must be replaced by the manufacturer, its 

service agent or similarly qualifi ed persons in order to avoid a hazard.

Mounting Bracket

Outlet

Inlet

FLEXIBLE DUC T

FIT GROMME T

S UPPLIED

MOUNTING

BRA CKE TS

RUBBER ROOF

FLASHING

PO WER  CA B LE 1200mm

ø403 / 445

ø194 DUCT

597.5 / 599

133 / 154

ER-765/1140 Dimensions 
ER-2010 Dimensions

Содержание MILANO+

Страница 1: ...INSTALLATION MANUAL falmecau com Milano Genova 120...

Страница 2: ...REVIEW YOUR NEW ITEM TO ENSURE THAT IT HASN T BEEN DAMAGED IN TRANSIT OR IS MISSING ANY COMPONENTS FAILURE TO REPORT ANY ISSUE WITHIN 72 HOURS OF RECEIPT OF YOUR ITEM MAY RESULT IN ADDITIONAL CHARGES...

Страница 3: ...4 Duct Clamps x4 5 200 mm Flexi Duct 5 Meters Length 6 White Stainless Steel Wall Eave Vent OPTION 2 EXTERNAL HOOD SOLUTION Fig B Models include ER 765 ER 1140 and ER 2010 Unit designed to be mounted...

Страница 4: ...4 512 822 250 505 815 541 851 12 379 665 358 184 541 851 280 118 200 280 247 332 204 MILANO 56 87 FP3ML60S2 FP3ML90S2 EN HOLE MEASUREMENTS FOR INSTALLATION IT MISURE FORO PER INCASSO...

Страница 5: ...5 851 1137 12 815 1101 98 351 584 870 360 118 0 0 2 851 1137 824 1110 330 360 326 326 248 204 MILANO 87 116 DEEP FP3MLD90S2 FP3MLD12S2 EN HOLE MEASUREMENTS FOR INSTALLATION IT MISURE FORO PER INCASSO...

Страница 6: ...6 1137 12 1101 98 351 870 450 118 0 0 2 1137 1110 420 450 326 416 281 204 GENOVA 116 FP3GV12S2 EN HOLE MEASUREMENTS FOR INSTALLATION IT MISURE FORO PER INCASSO...

Страница 7: ...7 600 650 mm 2 STEP 1 Minimum distance by cooktop STEP 2 Wall unit hole STEP 3 You push the hood in wall unit hole 3 1...

Страница 8: ...N TOP DUCTED POSITION 2 3 1 ATTENTION ONLY ON MILANO DEEP 3 x4 CAUTION CAUTION 10 28 mm 5 5a 4 STEP 4 You screw the blocking devices STEP 5 Connect the hood outlet in the top or back ducted position t...

Страница 9: ...5 4 ATTENTION ONLY ON MILANO 87 DEEP FOR BACK DUCTED POSITION 5 4 ATTENTION ONLY ON MILANO 87 DEEP 2 3 1 5b 5c 6 7 STEP 6 Attach the male plug of the rangehood unit to the main power supply STEP 7 As...

Страница 10: ...10 2 1 9 8 10 STEP 8 Remove the metal filters STEP 9 Remove the cover caps STEP 10 With your finger enter the hole and pull the lever to unlock the stop SEQUENCE FOR REMOVING THE HOOD...

Страница 11: ...hat the electrical mains power supply corresponds with what is report ed on the identification plate located inside the hood If the supply cord is damaged it must be replaced by the manufacturer its s...

Страница 12: ...harge of air must be fulfilled INSTALLATION only intended for qualified personnel Before installing the hood carefully read the chapter SAFETY INSTRUCTIONS AND WARNINGS TECHNICAL FEATURES The technica...

Страница 13: ...t on and off Long impulse change light tone from 2700K to 5600K SENSOR FUNCTION AVAILABLE ONLY ON MILANO 87 DEEP 1 2 3 4 5 6 TIMER red LED flashing Auto switch off after 15 min The function deactivate...

Страница 14: ...ufacturer declines all responsibility for failure to comply with these in structions CLEANING OF INTERNAL SURFACES Do not clean electrical parts or parts related to the motor inside the hood with liqu...

Страница 15: ...ty The external and in roof motors unit should be checked regularly to ensure that nothing is obstructing the air flow from the housing We also recommend a routine inspection of the remote units every...

Страница 16: ...ulled tight and excess removed IN ROOF MOTOR SOLUTION 765 1140m3 h 1 Fan power supply attached to internal hood unit 2 200mm flexi duct installed between rangehood and motor inlet 3 200mm flexi duct i...

Страница 17: ...xtension lead not supplied of up to five meters may be added if required EXTERNAL ROOF SOLUTION METAL ROOF INSTALLATION Inspection Ensure the unit has arrived in good condition and that the impeller w...

Страница 18: ...e replaced by the manufacturer its service agent or similarly qualified persons in order to avoid a hazard EXTERNAL WALL SOLUTION Inspection Ensure the unit has arrived in good condition and that the...

Страница 19: ...19 ENGLISH 518 147 450 419 123 360 EW 765 EW 1140 SPECIFICATIONS EW 2010 SPECIFICATIONS 130 80 162 5 325 298 6 5 4 holes 425 388 6 5 4 holes 170 80 212 5 All measurements in mm All measurements in mm...

Страница 20: ...the appliance location and return Any travel in excess of 50 km each way is not cov ered by the warranty PRKS has a service network in all metropolitan areas and most regional areas Where the warranty...

Страница 21: ...21 NOTE NOTES...

Страница 22: ...22 NOTE NOTES...

Страница 23: ...23 NOTE NOTES...

Страница 24: ...Code 110033077 Ed 05 2019...

Отзывы: