background image

11

ENGLISH

 SAFETY INSTRUCTIONS

 AND WARNINGS

Installation operations are to be carried 

out by skilled and qualified installers in ac-

cordance with the instructions in this booklet and 

in compliance with the regulations in force.
DO NOT use the hood if the power supply cable 

or other components are damaged:

 

disconnect 

the hood from the electrical power supply and con-

tact the Dealer or an authorised Servicing Dealer for 

repairs. 

Do not modify the electrical, mechanical or func-

tional structure of the equipment.
Do not personally try to carry out repairs or re-

placements. Interventions carried out by incompe-

tent and unauthorised persons can cause serious 

damage to the unit or physical and personal harm, 

not covered by the Manufacturer's warranty.

WARNINGS FOR THE INSTALLER

TECHNICAL SAFETY

Before installing the hood, check the in-

tegrity and function of each part. Should 

anomalies be noted, do not proceed with instal-

lation and contact the Dealer.
Do NOT install the hood if an aesthetic (or cos-

metic) defect has been detected. Put it back into 

its original package and contact the dealer.
No claim can be made for aesthetic (or cosmetic) 

defects once it has been installed.

During installation, always use personal protective 

equipment (e.g.: Safety shoes) and adopt prudent 

and proper conduct.
The installation kit (screws and plugs) supplied with the 

hood is only to be used on masonry walls: in case of in-

stallation on walls of a different material, assess other in-

stallation options keeping in mind the type of wall sur-

face and the weight of the hood (indicated on page 2).
Keep in mind that installations with different types of 

fastening systems from those supplied, or which are 

not compliant, can cause electrical and mechanical 

seal danger.
Do not install the hood outdoors and do not expose 

it to atmospheric elements (rain, wind, etc.).

ELECTRICAL SAFETY

The electrical system to which the hood 

is to be connected must be in accordance 

with local standards and supplied with earthed 

connection in compliance with safety regulations 

in the country of use. It must also comply with 

European standards regarding radio antistatic 

properties. 

Before installing the hood, check that the electrical 

mains power supply corresponds with what is report-

ed on the identification plate located inside the hood.

If the supply cord is damaged, it must be replaced by 

the manufacturer, its service agent or similarly qualified 

persons in order to avoid a hazard. The socket used to 

connect the installed equipment to the electrical pow-

er supply must be within reach: otherwise, install a 

mains switch to disconnect the hood when required. 

Any changes to the electrical system must be carried 

out by a qualified electrician. The maximum length of 

the flue fastening screws (supplied by the manufactur-

er) must be 13 mm. Use of non-compliant screws with 

these instructions can lead to danger of an electrical 

nature. Do not try to solve the problem yourself in the 

event of equipment malfunction, but contact the Deal-

er or an authorised Servicing Department for repairs.

When installing the hood, disconnect 

the equipment by removing the plug or 

switching off the main switch.

FUMES DISCHARGE SAFETY

Do no connect the equipment to discharge 

pipes of fumes produced from combustion 

(for example boilers, fireplaces, etc.).

Before installing the hood, ensure that all standards in 

force regarding discharge of air out of the room have 

been complied with.

USER WARNINGS

These warnings have been drawn up for 

your personal safety and those of others. 

You are therefore kindly asked to read the book-

let carefully in its entirety before using the or 

cleaning the equipment.
The Manufacturer declines all responsibility for 

any damage caused directly, or indirectly, to per-

sons, things and pets as a consequence of failing 

to comply with the safety warnings indicated in 

this booklet.
It is imperative that this instructions booklet is 

kept together with the equipment for any future 

consultation.

If the equipment is sold or transferred to another per-

son, make sure that the booklet is also supplied so 

that the new user can be made aware of the hood's 

operation and relative warnings. 
After the stainless steel hood has been installed, it will 

need to be cleaned to remove any residues remaining 

from the protection adhesive as well as any grease and 

oil stains which, if not removed, can cause irreversible 

damage to the hood surface. To properly clean the unit, 

the manufacturer recommends using the supplied 

moist wipes, which are also available sold separately. 
Insist on original spare parts.

Содержание MILANO+

Страница 1: ...INSTALLATION MANUAL falmecau com Milano Genova 120...

Страница 2: ...REVIEW YOUR NEW ITEM TO ENSURE THAT IT HASN T BEEN DAMAGED IN TRANSIT OR IS MISSING ANY COMPONENTS FAILURE TO REPORT ANY ISSUE WITHIN 72 HOURS OF RECEIPT OF YOUR ITEM MAY RESULT IN ADDITIONAL CHARGES...

Страница 3: ...4 Duct Clamps x4 5 200 mm Flexi Duct 5 Meters Length 6 White Stainless Steel Wall Eave Vent OPTION 2 EXTERNAL HOOD SOLUTION Fig B Models include ER 765 ER 1140 and ER 2010 Unit designed to be mounted...

Страница 4: ...4 512 822 250 505 815 541 851 12 379 665 358 184 541 851 280 118 200 280 247 332 204 MILANO 56 87 FP3ML60S2 FP3ML90S2 EN HOLE MEASUREMENTS FOR INSTALLATION IT MISURE FORO PER INCASSO...

Страница 5: ...5 851 1137 12 815 1101 98 351 584 870 360 118 0 0 2 851 1137 824 1110 330 360 326 326 248 204 MILANO 87 116 DEEP FP3MLD90S2 FP3MLD12S2 EN HOLE MEASUREMENTS FOR INSTALLATION IT MISURE FORO PER INCASSO...

Страница 6: ...6 1137 12 1101 98 351 870 450 118 0 0 2 1137 1110 420 450 326 416 281 204 GENOVA 116 FP3GV12S2 EN HOLE MEASUREMENTS FOR INSTALLATION IT MISURE FORO PER INCASSO...

Страница 7: ...7 600 650 mm 2 STEP 1 Minimum distance by cooktop STEP 2 Wall unit hole STEP 3 You push the hood in wall unit hole 3 1...

Страница 8: ...N TOP DUCTED POSITION 2 3 1 ATTENTION ONLY ON MILANO DEEP 3 x4 CAUTION CAUTION 10 28 mm 5 5a 4 STEP 4 You screw the blocking devices STEP 5 Connect the hood outlet in the top or back ducted position t...

Страница 9: ...5 4 ATTENTION ONLY ON MILANO 87 DEEP FOR BACK DUCTED POSITION 5 4 ATTENTION ONLY ON MILANO 87 DEEP 2 3 1 5b 5c 6 7 STEP 6 Attach the male plug of the rangehood unit to the main power supply STEP 7 As...

Страница 10: ...10 2 1 9 8 10 STEP 8 Remove the metal filters STEP 9 Remove the cover caps STEP 10 With your finger enter the hole and pull the lever to unlock the stop SEQUENCE FOR REMOVING THE HOOD...

Страница 11: ...hat the electrical mains power supply corresponds with what is report ed on the identification plate located inside the hood If the supply cord is damaged it must be replaced by the manufacturer its s...

Страница 12: ...harge of air must be fulfilled INSTALLATION only intended for qualified personnel Before installing the hood carefully read the chapter SAFETY INSTRUCTIONS AND WARNINGS TECHNICAL FEATURES The technica...

Страница 13: ...t on and off Long impulse change light tone from 2700K to 5600K SENSOR FUNCTION AVAILABLE ONLY ON MILANO 87 DEEP 1 2 3 4 5 6 TIMER red LED flashing Auto switch off after 15 min The function deactivate...

Страница 14: ...ufacturer declines all responsibility for failure to comply with these in structions CLEANING OF INTERNAL SURFACES Do not clean electrical parts or parts related to the motor inside the hood with liqu...

Страница 15: ...ty The external and in roof motors unit should be checked regularly to ensure that nothing is obstructing the air flow from the housing We also recommend a routine inspection of the remote units every...

Страница 16: ...ulled tight and excess removed IN ROOF MOTOR SOLUTION 765 1140m3 h 1 Fan power supply attached to internal hood unit 2 200mm flexi duct installed between rangehood and motor inlet 3 200mm flexi duct i...

Страница 17: ...xtension lead not supplied of up to five meters may be added if required EXTERNAL ROOF SOLUTION METAL ROOF INSTALLATION Inspection Ensure the unit has arrived in good condition and that the impeller w...

Страница 18: ...e replaced by the manufacturer its service agent or similarly qualified persons in order to avoid a hazard EXTERNAL WALL SOLUTION Inspection Ensure the unit has arrived in good condition and that the...

Страница 19: ...19 ENGLISH 518 147 450 419 123 360 EW 765 EW 1140 SPECIFICATIONS EW 2010 SPECIFICATIONS 130 80 162 5 325 298 6 5 4 holes 425 388 6 5 4 holes 170 80 212 5 All measurements in mm All measurements in mm...