 USING THE RADIO CONTROL (OPTIONAL)

 

WARNINGS!

Place the hood away from sources of electromagnetic waves (e.g. micro-

wave ovens), which could interfere with the radio control and with the 

hood electronics.

The maximum operating distance is 5 metres, that may vary according to 

the presence of electromagnetic interferences. 

Radio control operated at 433.92MHz.

The radio control consists of two parts:

- the receiver built into the hood;

- the transmitter shown here in the figure.

REMOTE CONTROL

( and )

 

DESCRIPTION OF TRANSMITTING

COMMANDS

UP

Motor switch-on and speed increase 
from 1 to 4. Speed 4 is only active for 
10 minutes.

DOWN

speed decrease and motor switch-OFF.

Dynamic Led

Short impulse: 

turn light on and off

Long impulse:

change light tone from 2700K to 5600K

TIMER ON:

 The motor automatically 

switches off after 15 min.
The function is automatically disabled if 
the motor is switched off (

 key)

 

Command transmission active

REMOTE CONTROL WITH SENSOR FUNCTION

(AVAILABLE ONLY ON 87 DEEP)

 

DESCRIPTION OF TRANSMITTING

COMMANDS

UP

Motor switch-on and speed increase 
from 1 to 4. Speed 4 is only active for 
10 minutes.

DOWN

With motor ON:

speed decrease and motor switch-OFF.

With motor OFF:

activation of the automatic cycle mode.

Dynamic Led

Short impulse: 

turn light on and off

Long impulse:

change light tone from 2700K to 5600K

TIMER ON: 

The motor automatically 

switches off after 15 min.
The function is automatically disabled if 
the motor is switched off (

 key)

 

Command transmission active

ACTIVATION PROCEDURE

Before using the radio control, follow the procedure below on the 

hood push-

button panel:

•  Press LIGHT 

 and TIMER 

 simultaneously until all LEDs start flashing. 

•  Release the two keys and press LIGHT 

 again until all LEDs are lit up. 

•  Release LIGHT 

: now the receiver is active.

This procedure is also used to deactivate the receiver.

Speed 2 activation

Speed 3 activation

Speed 4 activation for 10 minutes only

 

Dynamic Led

Short impulse: turn light on and off.
Long impulse: change light tone from 2700K to 5600K.

SENSOR FUNCTION

(AVAILABLE ONLY ON 87 DEEP)

1

2

3

4

5

6

TIMER (red LED flashing)

Auto switch-off after 15 min.
The function deactivates (red LED off ) if:
- The TIMER (key 

 ) is pressed again.

- The ON/OFF (key 

 ) is pressed.

FILTER ALARM (red LED steady on)

Anti-grease filter maintenance after approximately 30 hours of oper-
ation. Press and hold the button for 3 seconds to reset.

ON/OFF Key

Upon start-up, the speed is that stored at the previous operation.

Speed decrease

The speeds are indicated by the 
LEDs on the keys:

 Speed 1

 Speed 2

 Speed 3

 Speed 4 

("+" LED flashing)

Speed increase

Automatic cycle

Turns on and off the automatic mode of the hood with the air quality 
sensor. It takes 3 minutes to initialise the air quality sensor.

 

Dynamic Led

Short impulse: turn light on and off.
Long impulse: change light tone from 2700K to 5600K.

AUTOMATIC CYCLE 

 

   

First start-up: 

do not switch the extractor fan or the light on for 15 minutes at 

the first connection to the power supply.
The air quality sensor is calibrated during this time.
When calibration is completed, the 

 LED goes out.

If the self-installation procedure is interrupted by turning on the hood light or the 
motor, the system will try to repeat it 30 minutes after the hood is switched off.

Operation: 

Press 

 to activate the automatic cycle.

To heat the sensor, the hood runs at the second speed for 3 minutes. The LED 

 flashes. The air quality sensor then automatically controls the motor speed.

When the air quality is OK, the motor is switched off.

If either the motor or the light is switched on manually, the sensor heating will 
be activated so that if the 

 key is pressed the sensor will be ready for use.

The automatic cycle is interrupted if the 

 key is pressed, or 

 , and 

 .

Manual calibration of the air quality sensor (if necessary): 

The hood must be switched off; do not turn on the extractor fan and the light.
Do not perform any operations that can pollute the environmental conditions 
like turning on the burners or cooking.
Press and hold the 

 key to activate the calibration. The LED 

 flashes.

Calibration lasts 6 minutes. When calibration is completed, the 

 LED goes out.

Содержание MILANO+

Страница 1: ...INSTALLATION MANUAL falmecau com Milano Genova 120...

Страница 2: ...REVIEW YOUR NEW ITEM TO ENSURE THAT IT HASN T BEEN DAMAGED IN TRANSIT OR IS MISSING ANY COMPONENTS FAILURE TO REPORT ANY ISSUE WITHIN 72 HOURS OF RECEIPT OF YOUR ITEM MAY RESULT IN ADDITIONAL CHARGES...

Страница 3: ...4 Duct Clamps x4 5 200 mm Flexi Duct 5 Meters Length 6 White Stainless Steel Wall Eave Vent OPTION 2 EXTERNAL HOOD SOLUTION Fig B Models include ER 765 ER 1140 and ER 2010 Unit designed to be mounted...

Страница 4: ...4 512 822 250 505 815 541 851 12 379 665 358 184 541 851 280 118 200 280 247 332 204 MILANO 56 87 FP3ML60S2 FP3ML90S2 EN HOLE MEASUREMENTS FOR INSTALLATION IT MISURE FORO PER INCASSO...

Страница 5: ...5 851 1137 12 815 1101 98 351 584 870 360 118 0 0 2 851 1137 824 1110 330 360 326 326 248 204 MILANO 87 116 DEEP FP3MLD90S2 FP3MLD12S2 EN HOLE MEASUREMENTS FOR INSTALLATION IT MISURE FORO PER INCASSO...

Страница 6: ...6 1137 12 1101 98 351 870 450 118 0 0 2 1137 1110 420 450 326 416 281 204 GENOVA 116 FP3GV12S2 EN HOLE MEASUREMENTS FOR INSTALLATION IT MISURE FORO PER INCASSO...

Страница 7: ...7 600 650 mm 2 STEP 1 Minimum distance by cooktop STEP 2 Wall unit hole STEP 3 You push the hood in wall unit hole 3 1...

Страница 8: ...N TOP DUCTED POSITION 2 3 1 ATTENTION ONLY ON MILANO DEEP 3 x4 CAUTION CAUTION 10 28 mm 5 5a 4 STEP 4 You screw the blocking devices STEP 5 Connect the hood outlet in the top or back ducted position t...

Страница 9: ...5 4 ATTENTION ONLY ON MILANO 87 DEEP FOR BACK DUCTED POSITION 5 4 ATTENTION ONLY ON MILANO 87 DEEP 2 3 1 5b 5c 6 7 STEP 6 Attach the male plug of the rangehood unit to the main power supply STEP 7 As...

Страница 10: ...10 2 1 9 8 10 STEP 8 Remove the metal filters STEP 9 Remove the cover caps STEP 10 With your finger enter the hole and pull the lever to unlock the stop SEQUENCE FOR REMOVING THE HOOD...

Страница 11: ...hat the electrical mains power supply corresponds with what is report ed on the identification plate located inside the hood If the supply cord is damaged it must be replaced by the manufacturer its s...

Страница 12: ...harge of air must be fulfilled INSTALLATION only intended for qualified personnel Before installing the hood carefully read the chapter SAFETY INSTRUCTIONS AND WARNINGS TECHNICAL FEATURES The technica...

Страница 13: ...t on and off Long impulse change light tone from 2700K to 5600K SENSOR FUNCTION AVAILABLE ONLY ON MILANO 87 DEEP 1 2 3 4 5 6 TIMER red LED flashing Auto switch off after 15 min The function deactivate...

Страница 14: ...ufacturer declines all responsibility for failure to comply with these in structions CLEANING OF INTERNAL SURFACES Do not clean electrical parts or parts related to the motor inside the hood with liqu...

Страница 15: ...ty The external and in roof motors unit should be checked regularly to ensure that nothing is obstructing the air flow from the housing We also recommend a routine inspection of the remote units every...

Страница 16: ...ulled tight and excess removed IN ROOF MOTOR SOLUTION 765 1140m3 h 1 Fan power supply attached to internal hood unit 2 200mm flexi duct installed between rangehood and motor inlet 3 200mm flexi duct i...

Страница 17: ...xtension lead not supplied of up to five meters may be added if required EXTERNAL ROOF SOLUTION METAL ROOF INSTALLATION Inspection Ensure the unit has arrived in good condition and that the impeller w...

Страница 18: ...e replaced by the manufacturer its service agent or similarly qualified persons in order to avoid a hazard EXTERNAL WALL SOLUTION Inspection Ensure the unit has arrived in good condition and that the...

Страница 19: ...19 ENGLISH 518 147 450 419 123 360 EW 765 EW 1140 SPECIFICATIONS EW 2010 SPECIFICATIONS 130 80 162 5 325 298 6 5 4 holes 425 388 6 5 4 holes 170 80 212 5 All measurements in mm All measurements in mm...

Страница 20: ...the appliance location and return Any travel in excess of 50 km each way is not cov ered by the warranty PRKS has a service network in all metropolitan areas and most regional areas Where the warranty...

Страница 21: ...21 NOTE NOTES...

Страница 22: ...22 NOTE NOTES...

Страница 23: ...23 NOTE NOTES...

Страница 24: ...Code 110033077 Ed 05 2019...

Отзывы: