35
Section 6: Maintenance
Figure 56
Desiccant Cartridge
Figure 55
Desiccant Cartridge Housing
Desiccant Cartridge Inlet/Outlet Ports
Rubber Bushings
Desiccant Housing
Retainer Clips
4.
Grasp the desiccant cartridge with one hand
and pull the desiccant cartridge straight out of
the machine. If rubber bushings are attached
to desiccant filter, remove and replace in
machine
[Figure 55]
. Properly dispose of used
desiccant cartridge.
5.
Obtain a new desiccant cartridge
[Figure 56]
.
6.
Align the new desiccant cartridge with the
desiccant cartridge inlet/outlet ports. Push
the desiccant cartridge straight into the F400
desiccant housing until the cartridge snaps into
the retainer clips.
7.
Power on the machine, and proceed to
maintenance screen. Push the aeration button.
Verify the humidity level is dropping. If it is not,
the desiccant is not seated correctly in the rubber
bushing. Remove desiccant cartridge, reposition
rubber bushing and reinstall cartridge.
8.
Once the cartridge is properly installed. Replace
desiccant cover and install six screws to secure.