Follow thermostat phial capillary tube to pan boss in front wall and unscrew small compression nut that
seals tube.
Remove phial cover plate from pan and withdraw phial. Disconnect wires from terminal block.
Re-assemble parts in reverse order.
3.7 MULTIFUNCTIONAL GAS CONTROL
(MFC)
Unit is fitted with an SIT 820 Nova mV control incorporating cock, governor, valve and flame
failure device.
3.7.1 Removal of Multifunctional Control
(MFC)
Isolate main gas supply.
Remove cover plates that surround MFC.
Disconnect thermocouple connection on MFC and pull thermocouple clear. Undo thermopile
connections and withdraw.
Undo main gas inlet and outlet connections to MFC and withdraw control. Replace in reverse order
taking care when reconnecting thermocouple.
DO NOT overtighten as this may cause damage, hand tight plus a quarter turn is sufficient.
SIT Nova Multifunctional Control (MFC)
Pilot adjustment screw
TH
TP
TH/TP
Burner pressure adjustment screw
3.8 GOVERNOR
A governor is built in to the multifunctional control.
Refer to Sections 1.9 and 3.7.
3.9 DOUBLE CHECK VALVE
A double check valve is fitted at water inlet. This component is maintenance free.
If a replacement is required, ensure flow direction arrow points in the direction of intended flow.
This device must always be fitted to prevent contamination of potable water supply.
3.10 WATER TAP
Located at rear hob.
Turn off water supply before disconnecting tap.
To replace tap, remove facia panel, door and side panel to gain access. Replace in reverse order.
To gain access to internal head work, undo hex fitting behind control lever and remove.
Upon completion, ensure assembly is watertight.
3.11 DRAIN VALVE
If drain valve requires replacing, ensure pan is drained before removing valve.
Ensure replacement is fitted in correct orientation.
Upon completion, ensure valve opens and closes effectively.