Follow thermostat phial capillary tube to pan boss in front  wall  and  unscrew  small  compression  nut  that 

seals tube.

 

Remove phial cover plate from pan and withdraw phial.  Disconnect wires from terminal block.

 

Re-assemble parts in reverse order.

 

 

 

3.7 MULTIFUNCTIONAL GAS CONTROL 

(MFC)

 

Unit  is  fitted  with  an  SIT  820  Nova  mV  control  incorporating  cock,  governor,  valve  and  flame 

failure  device.

 

3.7.1 Removal of Multifunctional Control 

(MFC)

 

Isolate main gas supply.

 

Remove cover plates that surround MFC.

 

Disconnect  thermocouple  connection  on  MFC  and  pull  thermocouple  clear.  Undo  thermopile 

connections  and  withdraw.

 

Undo  main  gas  inlet  and  outlet  connections  to  MFC  and  withdraw  control.  Replace  in  reverse  order 

taking care  when reconnecting thermocouple.

 

DO  NOT  overtighten  as  this  may  cause  damage,  hand tight plus a quarter turn is sufficient.

 

 

SIT Nova Multifunctional Control (MFC)   

Pilot adjustment screw

 

 

 

 
 
 

 
 
 

TH

 

 

  

 

TP

 

 

TH/TP

 

 

 
 
 

Burner pressure  adjustment screw

 

 

3.8 GOVERNOR 

 

A  governor  is  built  in  to  the  multifunctional  control.

 

Refer to Sections 1.9 and 3.7. 

 

3.9 DOUBLE CHECK VALVE

 

A double check valve is fitted at water inlet.  This component is maintenance free.

 

If a replacement is required, ensure flow direction arrow  points in the direction of intended flow.

 

This  device  must  always  be  fitted  to  prevent  contamination of potable water supply.

 

 

3.10 WATER TAP

 

Located at rear hob.

 

Turn off water supply before disconnecting tap.

 

To replace tap, remove facia panel, door and side panel  to gain access. Replace in reverse order.

 

To  gain  access  to  internal  head  work,  undo  hex  fitting  behind control lever and remove.

 

Upon completion, ensure assembly is watertight.

 

 

 

3.11 DRAIN VALVE

 

If drain valve requires replacing, ensure pan is drained before removing valve.

 

Ensure replacement is fitted in correct orientation.

 

Upon   completion,   ensure   valve   opens   and   closes  effectively. 

Содержание G3203

Страница 1: ...d be left with the Engineer in Charge for reference during servicing Further to this the Users Instructions should be handed over to the User having had a demonstration of the operation and cleaning of the appliance IT IS MOST IMPORTANT THAT THESE INSTRUCTIONS BE CONSULTED BEFORE INSTALLING AND COMMISSIONING THIS APPLIANCE FAILURE TO COMPLY WITH THE SPECIFIED PROCEDURES MAY RESULT IN DAMAGE OR THE...

Страница 2: ...ion systems Gas water and electrical supply external to unit Light bulbs Re installing vacuum in kettle jackets Replacement of grill burner ceramics when damage has been clearly caused by misuse Where an engineer finds no fault with a product that has been reported faulty Re setting or adjustment of thermostats when unit is operating to specification Cleaning and unblocking of fryer filter systems...

Страница 3: ...1 The retaining chain has a quick release eyelet Secure to fixing point and secure bracket to floor after alignment with anti tipping device attached to the boiler Adjust to slide below floor bracket Figure 1 Anti tipping Bracket Important If appliance is to be installed in suite formation with other matching units the instructions for all models must be consulted to determine the necessary cleara...

Страница 4: ...t be smaller than gas inlet connection G3203 Rp BSP G3206 Rp BSP If flexible tube is used the gas supply tubing or hose shall comply with national requirements in force The hose shall not exceed 1 5m length These will be periodically examined and replaced as necessary An isolating cock must be located close to the unit to allow shutdown during an emergency or servicing The installation should be c...

Страница 5: ...er manifold and the operating pressure is shown in the tables below An adjustable governor is included in the multifunctional control on Natural Gas models Refer to Sections 2 6 1 setting the gas pressure and 3 7multifunctional control Supply Pressure Gas type mbar inches w g Natural Gas I2 H 20 8 Propane Gas I3P 37 14 8 1 9 2 All Models Burner Pressure Gas type mbar inches w g Natural Gas I2 H 15...

Страница 6: ...operation ensure that all packing material has been removed from unit 2 6 1 Setting The Gas Pressure It is necessary to check gas pressure during commissioning A suitable pressure gauge must be connected to test point on supply manifold a Ensure pan is filled with water b Turn on main gas valve at supply c Light burners as detailed in User Instructions The supply pipes may contain air therefore it...

Страница 7: ...ner Assembly Turn off main gas supply to unit Remove fixings that secure pilot and cross lighter assemblies to main burner and drop assemblies slightly Disconnect compression joint above manifold Remove fixings that retain burner assembly front cross strap to side runners Pull burner assembly forward approx 25mm and drop it slightly to clear front cross strap While supporting weight of assembly pu...

Страница 8: ...r to level mark Warning Filling an overheated pan with water is dangerous and may cause damage to pan structure In the event of failure with full pan replace safety stat 3 6 1 Removal of Operating Thermostat Isolate main gas supply and drain cooled water from pan Remove control knob from user thermostat and undo fixings alongside user thermostat spindle Undo control panel fixings Follow thermostat...

Страница 9: ... is sufficient SIT Nova Multifunctional Control MFC Pilot adjustment screw TH TP TH TP Burner pressure adjustment screw 3 8 GOVERNOR A governor is built in to the multifunctional control Refer to Sections 1 9 and 3 7 3 9 DOUBLE CHECK VALVE A double check valve is fitted at water inlet This component is maintenance free If a replacement is required ensure flow direction arrow points in the directio...

Страница 10: ...ation can be found on the data plate attached to base panel The following parts may require replacing during the life of this appliance Safety thermostat Spark igniter Spark ignition electrode Operating thermostat Multifunctional control MFC Thermocouple c w interrupter Thermopile Pilot assembly ...

Отзывы: