SECTION 2 -

 

ASSEMBLY and COMMISSIONING

 

 

2.1 ASSEMBLY

 

The  unit  is  packed  as  a  complete  assembly,  except  flue  and  water    tap  faucet.  To  fit,  slide  flue  over 

upstand on  hob  rear  and  secure  with  fixings  along  lower  front  and  rear  edges.  Slot  basket  hanger 

over  knurled  nuts  and  hand-tighten.

 

Fit faucet to top of water tap and fully tighten.

 

 

 

2.2 APPLIANCES ON CASTORS

 

For  units  on  castors,  refer  to  guidelines  in  BS6173.   

 

Warning: Appliances on Castors.

 

When  the  boiler  is  supplied  with  castors  it  should  be  connected  to  supply  piping  by  means  of  a 
connector  for  moveable  appliances.  I n   a d d it i o n ,  a  restraining  chain  should  be  connected  between 
appliance and wall. Ensure this restraint is re-connected when unit is returned to original position.

 

 

2.3 CONNECTION TO A GAS SUPPLY

 

Gas  supply  piping  and  unit  connection  must  be  installed  in  accordance  with  regulations  listed  on front 

page of this  document.

 

A gas  isolating  cock  must  be  fitted  to  the  supply  in  a  position that is readily accessible to operator.

 

 

2.4 CONNECTION TO AN ELECTRICAL SUPPLY

 

Not applicable to these units.

 

 

 

2.5 CONNECTION TO A WATER SUPPLY

 

Connect water supply as detailed in Section 1.6.

 

Ensure drain valve is closed and fill pan with fresh water  to maximum level mark.

 

 

2.6 PRE-COMMISSIONING CHECK

 

Prior to operation, ensure that all packing material has  been removed from unit.

 

2.6.1 Setting The Gas Pressure

 

It  is  necessary  to  check  gas  pressure  during  commissioning.  A  suitable  pressure  gauge  must  be 

connected to test point on supply manifold.

 

a) Ensure pan is filled with water.

 

b) Turn on main gas valve at supply.

 

c)  Light  burners  as  detailed  in  User   Instructions.  The  supply pipes may contain air therefore it may 

be  necessary to repeat lighting procedure.

 

d)  Adjust  multifunctional  control  pressure  governor  to  relevant  setting  as  detailed  in  Section  1.9  of 

this  document.  The  screw  should  be  turned  clockwise  to increase  pressure  and  anti-clockwise  to 

reduce  it.  Check again after 15 minutes of operation.

 

e) Disconnect pressure gauge from test point.  Replace  sealing screw and test gas tightness.

 

f)  Ensure  thermostat  satisfactorily  operates  around  boiling  point.  It  should  be  possible  to  establish 

conditions  of simmer 

(pulsing heat) 

and continuous  boiling.

 

g)  Check for water leaks at inlet, fill tap, drain valve and  pan.

 

h) Position a water collector at drain outlet. Ensure drain  valve closes effectively and opens with ease.

 

 

2.7 INSTRUCTION TO USER

 

After  installing  and  commissioning  the  unit,  hand  User  Instructions  to  operator  or  purchaser.  Ensure 

details  to  light,  turn  off,  use  and  clean  are  properly  understood.  The  locations  of  main  gas  and  water 

isolating  valves  should  be  made  known  to  user  and  the  procedure  for  operation  in  event  of  an 

emergency should be  demonstrated.

 

Содержание G3203

Страница 1: ...d be left with the Engineer in Charge for reference during servicing Further to this the Users Instructions should be handed over to the User having had a demonstration of the operation and cleaning of the appliance IT IS MOST IMPORTANT THAT THESE INSTRUCTIONS BE CONSULTED BEFORE INSTALLING AND COMMISSIONING THIS APPLIANCE FAILURE TO COMPLY WITH THE SPECIFIED PROCEDURES MAY RESULT IN DAMAGE OR THE...

Страница 2: ...ion systems Gas water and electrical supply external to unit Light bulbs Re installing vacuum in kettle jackets Replacement of grill burner ceramics when damage has been clearly caused by misuse Where an engineer finds no fault with a product that has been reported faulty Re setting or adjustment of thermostats when unit is operating to specification Cleaning and unblocking of fryer filter systems...

Страница 3: ...1 The retaining chain has a quick release eyelet Secure to fixing point and secure bracket to floor after alignment with anti tipping device attached to the boiler Adjust to slide below floor bracket Figure 1 Anti tipping Bracket Important If appliance is to be installed in suite formation with other matching units the instructions for all models must be consulted to determine the necessary cleara...

Страница 4: ...t be smaller than gas inlet connection G3203 Rp BSP G3206 Rp BSP If flexible tube is used the gas supply tubing or hose shall comply with national requirements in force The hose shall not exceed 1 5m length These will be periodically examined and replaced as necessary An isolating cock must be located close to the unit to allow shutdown during an emergency or servicing The installation should be c...

Страница 5: ...er manifold and the operating pressure is shown in the tables below An adjustable governor is included in the multifunctional control on Natural Gas models Refer to Sections 2 6 1 setting the gas pressure and 3 7multifunctional control Supply Pressure Gas type mbar inches w g Natural Gas I2 H 20 8 Propane Gas I3P 37 14 8 1 9 2 All Models Burner Pressure Gas type mbar inches w g Natural Gas I2 H 15...

Страница 6: ...operation ensure that all packing material has been removed from unit 2 6 1 Setting The Gas Pressure It is necessary to check gas pressure during commissioning A suitable pressure gauge must be connected to test point on supply manifold a Ensure pan is filled with water b Turn on main gas valve at supply c Light burners as detailed in User Instructions The supply pipes may contain air therefore it...

Страница 7: ...ner Assembly Turn off main gas supply to unit Remove fixings that secure pilot and cross lighter assemblies to main burner and drop assemblies slightly Disconnect compression joint above manifold Remove fixings that retain burner assembly front cross strap to side runners Pull burner assembly forward approx 25mm and drop it slightly to clear front cross strap While supporting weight of assembly pu...

Страница 8: ...r to level mark Warning Filling an overheated pan with water is dangerous and may cause damage to pan structure In the event of failure with full pan replace safety stat 3 6 1 Removal of Operating Thermostat Isolate main gas supply and drain cooled water from pan Remove control knob from user thermostat and undo fixings alongside user thermostat spindle Undo control panel fixings Follow thermostat...

Страница 9: ... is sufficient SIT Nova Multifunctional Control MFC Pilot adjustment screw TH TP TH TP Burner pressure adjustment screw 3 8 GOVERNOR A governor is built in to the multifunctional control Refer to Sections 1 9 and 3 7 3 9 DOUBLE CHECK VALVE A double check valve is fitted at water inlet This component is maintenance free If a replacement is required ensure flow direction arrow points in the directio...

Страница 10: ...ation can be found on the data plate attached to base panel The following parts may require replacing during the life of this appliance Safety thermostat Spark igniter Spark ignition electrode Operating thermostat Multifunctional control MFC Thermocouple c w interrupter Thermopile Pilot assembly ...

Отзывы: