3.4 FLAME FAILURE THERMOCOUPLE

 

Undo nuts at pilot assembly and valve body.

 

Disconnect thermocouple interrupter from terminal block. 

 

3.5 PIEZO IGNITER/SPARK ELECTRODE

 

The  igniter  is  a  piezo  spark  type.  The  electrode  is  mounted  upon  pilot  burner  bracket  and  switch  is 

adjacent  to MFC. The lead has a push on connection at both ends.

 

3.5.1 Removal of Igniter Switch

 

Remove igniter lead connection to switch.

 

Undo   fixings   that   secure   switch   flange   to   control  compartment  and remove device.

 

Replace in reverse order.

 

3.5.2 Removal of the Electrode

 

Remove  igniter  lead  connection  from  electrode  and  remove  nut  located  below  electrode.  Withdraw 

electrode  downward from pilot burner bracket.

 

Replace in reverse order.

 

 

 

3.6 THERMOSTATS

 

The user thermostat is an EGO, snap action control with  adjustment of temperature up to continuous boil.

 

The  overheat  thermostat  is  an  EGO  model  with  interrupter  that  will  cut  burner  operation  if  the  pan 
overheats 

(e.g. - no water in pan)

 

Note

 

Manual intervention is required to reset control in event of  cut-out.

 

To Reset Safety Thermostat

 

Allow pan to cool down.

 

Remove black plastic safety cover and push reset button.  Fill pan with cold water to level mark

 

Warning:    Filling    an    overheated    pan    with    water    is  dangerous  and  may  cause  damage  to  pan 
structure. 
 
In the event of failure with full pan, replace safety stat. 

3.6.1 Removal of Operating Thermostat

 

Isolate main gas supply and drain cooled water from pan.

 

Remove  control  knob  from  user  thermostat  and  undo  fixings alongside user thermostat spindle.

 

Undo  control  panel  fixings.  Follow  thermostat  phial  capillary  tube  to  pan  boss  in  front  wall  and  undo 

small  compression nut that seals tube.

 

Remove  phial  cover  plate  from  inside  pan  and  withdraw  thermostat  phial.  Disconnect  thermostat 

electrical  connections prior to removing thermostat.

 

Replace in reverse order. 

 

3.6.2 Recalibration of User Thermostat

 

Remove knob from thermostat spindle taking care not to  rotate  it  in  either  direction  as  this  would  change 

setting.  Steady spindle  and  rotate  calibration screw  clockwise  to  decrease and anti-clockwise to increase 

the temperature. 

 

3.6.3 Checking the User Thermostat Calibration 

Using  a  reliable  thermometer  immersed  25mm  below  water  surface  at  pan  centre.  Measure  water 
temperature  when a steady condition has been established.

 

It  is  important  that  calibration  is  set  to  guarantee  continuous boiling at top end.

 

3.6.4 Replacement of Safety Thermostat

 

Isolate  gas  supply  and  drain  cooled  water  from  pan.  Undo  fixings  that  secure  safety  thermostat  to 

bracket.

 

Содержание G3203

Страница 1: ...d be left with the Engineer in Charge for reference during servicing Further to this the Users Instructions should be handed over to the User having had a demonstration of the operation and cleaning of the appliance IT IS MOST IMPORTANT THAT THESE INSTRUCTIONS BE CONSULTED BEFORE INSTALLING AND COMMISSIONING THIS APPLIANCE FAILURE TO COMPLY WITH THE SPECIFIED PROCEDURES MAY RESULT IN DAMAGE OR THE...

Страница 2: ...ion systems Gas water and electrical supply external to unit Light bulbs Re installing vacuum in kettle jackets Replacement of grill burner ceramics when damage has been clearly caused by misuse Where an engineer finds no fault with a product that has been reported faulty Re setting or adjustment of thermostats when unit is operating to specification Cleaning and unblocking of fryer filter systems...

Страница 3: ...1 The retaining chain has a quick release eyelet Secure to fixing point and secure bracket to floor after alignment with anti tipping device attached to the boiler Adjust to slide below floor bracket Figure 1 Anti tipping Bracket Important If appliance is to be installed in suite formation with other matching units the instructions for all models must be consulted to determine the necessary cleara...

Страница 4: ...t be smaller than gas inlet connection G3203 Rp BSP G3206 Rp BSP If flexible tube is used the gas supply tubing or hose shall comply with national requirements in force The hose shall not exceed 1 5m length These will be periodically examined and replaced as necessary An isolating cock must be located close to the unit to allow shutdown during an emergency or servicing The installation should be c...

Страница 5: ...er manifold and the operating pressure is shown in the tables below An adjustable governor is included in the multifunctional control on Natural Gas models Refer to Sections 2 6 1 setting the gas pressure and 3 7multifunctional control Supply Pressure Gas type mbar inches w g Natural Gas I2 H 20 8 Propane Gas I3P 37 14 8 1 9 2 All Models Burner Pressure Gas type mbar inches w g Natural Gas I2 H 15...

Страница 6: ...operation ensure that all packing material has been removed from unit 2 6 1 Setting The Gas Pressure It is necessary to check gas pressure during commissioning A suitable pressure gauge must be connected to test point on supply manifold a Ensure pan is filled with water b Turn on main gas valve at supply c Light burners as detailed in User Instructions The supply pipes may contain air therefore it...

Страница 7: ...ner Assembly Turn off main gas supply to unit Remove fixings that secure pilot and cross lighter assemblies to main burner and drop assemblies slightly Disconnect compression joint above manifold Remove fixings that retain burner assembly front cross strap to side runners Pull burner assembly forward approx 25mm and drop it slightly to clear front cross strap While supporting weight of assembly pu...

Страница 8: ...r to level mark Warning Filling an overheated pan with water is dangerous and may cause damage to pan structure In the event of failure with full pan replace safety stat 3 6 1 Removal of Operating Thermostat Isolate main gas supply and drain cooled water from pan Remove control knob from user thermostat and undo fixings alongside user thermostat spindle Undo control panel fixings Follow thermostat...

Страница 9: ... is sufficient SIT Nova Multifunctional Control MFC Pilot adjustment screw TH TP TH TP Burner pressure adjustment screw 3 8 GOVERNOR A governor is built in to the multifunctional control Refer to Sections 1 9 and 3 7 3 9 DOUBLE CHECK VALVE A double check valve is fitted at water inlet This component is maintenance free If a replacement is required ensure flow direction arrow points in the directio...

Страница 10: ...ation can be found on the data plate attached to base panel The following parts may require replacing during the life of this appliance Safety thermostat Spark igniter Spark ignition electrode Operating thermostat Multifunctional control MFC Thermocouple c w interrupter Thermopile Pilot assembly ...

Отзывы: