8.0 FAULT FINDING
FAULT
POSSIBLE CAUSES
REMEDY
No power (red neon
extinguished)
Appliance disconnected from
mains power
Reconnect to mains power
No heat when thermostat
turned on (amber neon
extinguished)
Appliance internal fuse blown Investigate reason, rectify
fault, replace fuse
Faulty thermostat
Replace
Safety thermostat tripped
Reset/investigate reason
No heat when thermostat
turned on (amber neon
illuminated)
Faulty contactor
Replace
Faulty element
Replace
Appliance not hot enough
Faulty thermostat
Replace.
Note:
when checking plate
temperature, probe 210mm
in from each side halfway
between front and rear on
E9581 models. Probe centre
plate on E9541 models
9.0 SPARE PARTS
Mains Pilot light RED
730962010
Circuit Pilot light AMBER
730962040
Element 230V
733620006
Thermostat E9581/81R/41/41R
731910500
Thermostat E9581CR/41CR
733630002
Safety thermostat E9581CR/41CR
733630003
Control knob E9581/81R/41/41R
733620005
Control Knob E9581CR/41CR
733630004
When ordering spares, quote the following:
Model Number
Serial number
Gas Type
This information is found on data plate on front panel. (see section 1.0)
Visit our website for further spares information.
Содержание E9541
Страница 9: ...9 5 0 DIMENSIONS CONNECTION LOCATIONS...
Страница 11: ...11 6 2 2 Connect appliance to mains supply...
Страница 20: ...20 7 7 CIRCUIT DIAGRAMS 7 7 1 E9541 E9541R...
Страница 21: ...21 7 7 2 E9541CR...
Страница 22: ...22 7 7 3 E9581 E9581R...
Страница 23: ...23 7 7 4 E9581CR...
Страница 24: ...24 7 8 WIRING DIAGRAMS 7 8 1 E9541 E9541R...
Страница 25: ...25 7 8 1 E9541CR...
Страница 26: ...26 7 8 1 E9581 E9581R...
Страница 27: ...27 7 8 1 E9581CR...