6.3 COMMISSIONING
6.3.1 Remove rear access plate and control panel.
6.3.2 Push the power cable through the gland and feed to the mains connector block.
6.3.3 Attach appropriate 3 phase mains power cable with 32A plug.
6.3.4 Refit rear access panel and control panel.
6.3.5 Connect appliance to mains power.
6.3.6 Ensure red neon illuminates.
6.3.7 Turn thermostat(s) to desired temperature.
6.3.8 Ensure amber neon(s) illuminates.
6.3.9 This appliance is also provided with a terminal for connection of an external
equipotential conductor. This terminal is an effective electrical contact with all fixed
exposed metal parts of the appliance, and shall allow the connection of conductor
having a nominal cross-section area of up to 10mm².
it is located at the rear of the unit and identified by the following label and must only
be used for bonding purposes.
PLEASE FILL OUT THE INFORMATION TABLE ON THE FRONT COVER
AFTER COMMISSIONING.