01

Hardware over coil

Use of unsuitable pan material

Re-set required

Defective coil

Use suitable pan. 

Switch unit off for 10 seconds, then on

Engineer required

02

No inductor coil 

current

Re-set unit

Inductor coil connection failure

Switch unit off for 10 seconds, then on

Engineer required

03

Heat sink temperature 

too high

Re-set required

Air routes blocked

Air filter blocked 

(requires cleaning)

Generator fans clogged

Generator fan malfunction 

(due to clogging)

Generator fan malfunction 

(due to electrical fault)

Generator fan blows instead of

sucks

Room temperature abnormally high

External heat source too close

Defective generator temperature 

sensor

Switch unit off for 10 seconds, then on

Check below and rear of unit for potential 

airflow obstruction

Check filter, it may require cleaning/replacing

Is a filter fitted? Vacuum if necessary

Engineer required

Engineer required

Engineer required

Cool down room

Move appliance away from heat source

Engineer required

04

Cooking zone 

temperature too high 

or remains constant

during use

Re-set required

Pan empty or too hot

Cooking zone is self-protected due

to abnormal heat build up

Faulty temperature sensor

(constantly recording ambient)

Switch unit off for 10 seconds, then on

Check pan has not boiled dry or is empty.

Has a hot pan from another source been

positioned within zone to cause overheating?

Allow cook zone to cool for 2 minutes

Engineer required

05

Control failure

Re-set required

Faulty control or incorrect wiring

Switch unit off for 10 seconds, then on

Engineer required

06

Internal temperature

of generator too high

Re-set required

Refer to fault 03

Switch unit off for 10 seconds, then on

Refer to fault 03

07

Cooking zone 

temperature sensor

Reset required

Faulty/malfunctioning temperature

sensor

Switch unit off for 10 seconds, then on

Engineer required

08

Mains supply failure

Re-set required

Fault with mains supply

Switch unit off for 10 seconds, then on

Engineer required

09

N/A

N/A

N/A

Code

Error

Cause

Action by user

Содержание E2904i

Страница 1: ...rect operation and maintenance of the unit The equipment is designed for PROFESSIONAL USE and should only be operated by QUALIFIED persons It is the responsibility of the supervisor or equivalent to e...

Страница 2: ...watches bracelets etc worn by the user could become hot when in close proximity to the cooking zone Do not place credit cards etc on the glass ceramic top as data could be wiped off Never leave the i...

Страница 3: ...nob LED indicator Zone indication i e RH rear Unit will not Operate 110mm pan If inner circle markings can be seen the pan is too small Detection will prevent cooking using this size of pan Unit will...

Страница 4: ...Note This is also liable to happen if pans are damaged e g large dents Pot base is bowed inward and is NOT FLAT The unit efficiency will be dramatically reduced during cooking It may not even be detec...

Страница 5: ...anty The air intake filter MUST be in place during operation The glass ceramic top can be wiped clean using a damp cloth and warm soapy water For heavy stains use a scraper whilst cooking zone is stil...

Страница 6: ...able For example 6 short flashes followed by an extended flash would indicate error code 06 Generator internal temperature too high The codes are provided to diagnose possible faults and the action re...

Страница 7: ...Cool down room Move appliance away from heat source Engineer required 04 Cooking zone temperature too high or remains constant during use Re set required Pan empty or too hot Cooking zone is self pro...

Страница 8: ...or detects that current does not reflect what controls require Switch unit off for 10 seconds then on Engineer required 13 Mains connection error Re set required Mains voltage is too high or too low S...

Отзывы: