ERROR CODE TABLE

If any fault occurs during use, an error code 

corresponding to the details below will be displayed as

a series of flashes.

For example, 6 short flashes followed by a long flash

would indicate error code 06.

The codes will help determine unit faults and the table

lists actions required to remedy any such fault.

Note: most errors can be rectified by simply switching

the unit off at the main supply for 10 seconds and

switching back on.

SECTION 5 - TROUBLESHOOTING

If a fault occurs during use, an error code will be

displayed in a series of  flashes.

These correspond to the numbers in the code column of

the following table.

For example, 6 short flashes followed by an extended

flash would indicate error code 06

(Generator internal

temperature too high).

The codes are provided to diagnose possible faults and

the action required to remedy any such condition.

Note: Most faults can be rectified by simply

switching the unit off for 10 seconds. After this time,

turn the power back on at mains supply.

If the fault continues to occur after this action then

please refer to the table. This will provide the

solution to rectify the condition. 

SUPPLY PROTECTION DEVICE

The appliance is fitted with a miniature circuit breaker

(MCB) as additional protection against over current.

If unit fails to operate or show any operational indicators,

Follow details in Error Code Table before calling a

service engineer. The symptoms may indicate a failed

induction generator.

Содержание E2904i

Страница 1: ...rect operation and maintenance of the unit The equipment is designed for PROFESSIONAL USE and should only be operated by QUALIFIED persons It is the responsibility of the supervisor or equivalent to e...

Страница 2: ...watches bracelets etc worn by the user could become hot when in close proximity to the cooking zone Do not place credit cards etc on the glass ceramic top as data could be wiped off Never leave the i...

Страница 3: ...nob LED indicator Zone indication i e RH rear Unit will not Operate 110mm pan If inner circle markings can be seen the pan is too small Detection will prevent cooking using this size of pan Unit will...

Страница 4: ...Note This is also liable to happen if pans are damaged e g large dents Pot base is bowed inward and is NOT FLAT The unit efficiency will be dramatically reduced during cooking It may not even be detec...

Страница 5: ...anty The air intake filter MUST be in place during operation The glass ceramic top can be wiped clean using a damp cloth and warm soapy water For heavy stains use a scraper whilst cooking zone is stil...

Страница 6: ...able For example 6 short flashes followed by an extended flash would indicate error code 06 Generator internal temperature too high The codes are provided to diagnose possible faults and the action re...

Страница 7: ...Cool down room Move appliance away from heat source Engineer required 04 Cooking zone temperature too high or remains constant during use Re set required Pan empty or too hot Cooking zone is self pro...

Страница 8: ...or detects that current does not reflect what controls require Switch unit off for 10 seconds then on Engineer required 13 Mains connection error Re set required Mains voltage is too high or too low S...