To select the other speed output voltage, press and release the
Stby
button. The display will show
the newly selected speed, then revert to the output voltage for that speed selection. Increase or
decrease the output voltage for the selected speed as above.
When output voltage selections are complete, press and hold the
Stby
button; the display will show
“SAV” and the voltage outputs will be saved in non-volatile memory. The PSU will then return to
Standby Mode
.
Pulley Select Mode:
Pulley Select Mode
is used to specify which pulley your motor is fitted with
(either 50Hz or 60 Hz operation) and which spindle to use (small or large). As shipped from the
factory, the Falcon is set for the
small
spindle; extensive testing has shown this to be the most stable
option with the least vibration.
Enter
Pulley Select Mode
by removing the power plug from the Falcon. Press and hold the
Plus
button while inserting the power plug. The display will show
:
Release the
Plus
button and the display will show the currently selected pulley/spindle combination.
Use the
Plus
and
Minus
buttons to move through the 4 selections until the desired combination is
displayed. Press and hold the
Stby
button to save the selection and return to normal operation.
The 4 selections are 50Hz Small , 50Hz Large , 60Hz Small and
60Hz Large .