30
Australia
Electrical Connection
This appliance must be installed by a qualified
electrician to comply with the relevant regulations
and also the local electricity supply company
requirements.
Make sure that the mains characteristics (voltage,
nominal, power, etc.) match the ratings indicated on
the data plate affixed to the lower right hand cooker
upright (remove storage drawer). The cooker is preset
for a single-phase earthed electrical connection. It is
essential to install a multi-pole circuit breaker that
completely disconnects the appliance from the mains,
with a minimum contact break distance of 3mm.
WARNING: THIS APPLIANCE MUST BE EARTHED
The appliance must be connected to an efficient
earthing circuit. If the electricity network is not
equipped with an earth connection, then it must be
installed separately in compliance with local
regulations. Earthing is a safety measure required by
law, and must be performed with particular care by a
qualified technician, who must also check that the
electricity supply characteristics are correct.
The cable size used should be suitable for the
appliance load and in accordance with local
regulations. Please note the maximum cable sizes are
6mm
2
for the screw terminals and 10mm
2
for the 3
pronged links.
Access to the mains terminal is gained by removing the
electrical terminal cover box on the back panel.
Connect the mains cable to the correct terminals for
your electrical supply type (see fig.). You may need to
move the links to suit you connection type. Check that
the links are correctly fitted and that the terminal
screws are tight. Secure the mains cable using the
cable clamp.
This shows the single-phase connection.
These appliances are of type X with regard to
protection against over heating of the surrounding
surfaces.
Fixed Wiring.
For connection to fixed wiring i.e. flexible conduit,
remove the electrical terminal cover box on the back
panel. Remove two screws and blanking plate from the
bottom flange of the cover box, so as to allow the
conduit through.
Fix conduit to conduit mounting bracket on the back
panel. Connect mains cable to correct terminals for
your electrical supply type. Check that the links are
correctly fitted and the terminal screws are tight.
Replace electric terminal cover box making sure that
the conduit is clear of the bottom flange.