manualshive.com logo in svg
background image

26” Push System

Header/Frame and Door Preparation

6”

1

/

5

-

5

1

8”

/

3

-

9

Drop Mount Application (26” Push System Only)

Header/Frame and Door Preparation

6”

1

/

5

-

5

1

8”

/

3

-

9

Control

Box

Gearbox

6

4

1-3/16”

5/8”

26” Push System

Header/Frame and Door Preparation

6”

1

/

5

-

5

1

8”

/

3

-

9

Drop Mount Application (26” Push System Only)

Header/Frame and Door Preparation

6”

1

/

5

-

5

1

8”

/

3

-

9

Control

Box

Gearbox

6

4

1-3/16”

5/8”

Содержание 8230

Страница 1: ...y spring force The activating circuit opens the door from any position in the closing swing During a power failure the Falcon Operator acts as a manual door closer Size 3 Door opening and closing cycl...

Страница 2: ...al 1e Check door width 26 minimum for 26 Push Operator 30 minimum for 26 Pull Operator 1f Check that door weight is 200 lbs or less For heavier door consult factory 1g Check that a 115 volt single pha...

Страница 3: ...unting Bracket on Header Frame Do not install the center screws until you ve attached the Motor Gearbox assembly in step 2d 2d Install Motor Gearbox on Operator Mounting Bracket If there is not a moun...

Страница 4: ...sh System Only Header Frame and Door Preparation 6 1 5 5 1 8 3 9 Control Box Gearbox 6 4 1 3 16 5 8 26 Push System Header Frame and Door Preparation 6 1 5 5 1 8 3 9 Drop Mount Application 26 Push Syst...

Страница 5: ...not connect any remote activating device to the door unless it is located within line of sight of the door 3c When wiring is complete proceed to Step 4 Arm and Cover Installation page 6 4 Arm Cover I...

Страница 6: ...n 90 To adjust arm remove arm adjustment screws push door open to 90 and reinstall arm screws see fig 4 Pull Arm Fig 4 Fig 3 Arm Locking Screw Arm Adjustment Screws 8mm Socket Head Screw Pull Arm Fig...

Страница 7: ...tment on page 9 Below are default settings Opening Speed 9 00 Back Check Speed 3 00 Hold Open Time Delay 10 00 Latch Position 12 00 Closing Speed 12 00 Back Check Position 4 00 fully clockwise 5c If t...

Страница 8: ...Faster Back Check Speed Back Check Speed Controls the speed of the door near the full open position to prevent door slamming Slower Faster Hold Open Time Delay Hold Open Time Delay Controls the lengt...

Страница 9: ...ack Check Speed Back Check Pos Back Check Pos Close Speed Close Speed Latch Pos Latch Pos Hold Open Hold Open Push n Go Push n Go On Off Open Speed Open Speed Delay Delay On Off Main Power 12 VAC Powe...

Страница 10: ...charge with a contact name and phone number to call for future service and maintenance IMPORTANT Be sure to install all Safety Traffic Control and Instruction Labels onto the door as required 8 Falcon...

Страница 11: ...sed by driving the motor in the open direction a fixed setting power is added to allow the spring to continue closing the door to the Full Closed position 8b Wiring 24VDC 24VDC Electric Lock Electric...

Страница 12: ......

Отзывы: