![Fairchild FEBFAN9611 S01U300A Скачать руководство пользователя страница 9](http://html1.mh-extra.com/html/fairchild/febfan9611-s01u300a/febfan9611-s01u300a_user-manual_3227029009.webp)
© 2012 Fairchild Semiconductor Corporation
8
FEBFAN9611_S01U300A
• Rev. 0.0.1
Figure 5. Recommended Test Set-Up
All efficiency data shown in this document was taken using the test set up shown in
Figure 5 with the output voltage being measured directly at the output bulk capacitors
(not through the output connector (J2)).
Power-Off Procedure
1.
Make sure the electronic load is set to draw at least 100mA of constant DC current.
2.
Disconnect (shut down) AC line voltage source.
3.
Disconnect (shut down) 12V DC bias power supply.
4.
Disconnect (shut down) DC electronic load last to ensure that the output capacitors
are fully discharged before handling the evaluation module.
AC Source
PF, THD, P
IN
0-265V
AC
DVM
Current
DC Bias Supply
0-12V
DVM
Current
Electronic Load
400V, 0-1A
DVM
Voltage