background image

 

Pellets Stove

 

 
 

 

9

99

9    

 

INSTALLATION

INSTALLATION

INSTALLATION

INSTALLATION    

 

Introduction

Introduction

Introduction

Introduction    

 
The stove position must be chosen in accordance with the environment, the waste pipe and the chimney flue. 
Verify with the local authority if there are restrictive rules about the air intake for combustion purposes and 
ventilation of domestic environment and about the waste fumes pipes plant with chimney flue and chimney 
pot. The manufacturer declines any responsibility in case of installation not in accordance with the standards 
in force, with a not correct ventilation system, an electrical connection not in accordance with the standards in 
force, or in case of bad use of the appliance. The installation must be carried out by a qualified technician 
who will sign a declaration of conformity of the system and take all responsibility for the installation and good 
functioning of the appliance. A booklet of testing and periodic maintenance to be carried out by the installer is 
issued to the client together with the stove. 
 

Installation

Installation

Installation

Installation    

 
The appliance should be installed on a floor with adequate load bearing capacity. If the existing structure 
does not satisfy this requirement it is essential to take appropriate precautions (e.g. install a load distribution 
plate). When the appliance is installed it should be placed so as to allow easy access for cleaning the stove 
itself, the exhaust gas ducts and the chimney flue. 
The pellets stove must be installed in isolation, with a minimum air space of 15 cm to allow an adequate 
cooling of the appliance and a good distribution of heat in the domestic environment. In compliance with fire-
prevention methods there must be a minimum distance of at least 20 cm from flammable objects (sofas, 
furniture, wooden covering) to the back and side of the stove and of 80 cm to the front where the fire door is. 
If the floor is made of flammable material you must prepare a coverage made of non-flammable material 
(plate of steel, marble, refractory material), which sticks out 50 cm from the front of the stove where the fire 
door is and 20 cm from the other sides (see picture 10). You can’t install the stove in bedrooms or 
bathrooms. 
 

 

Pic. 10 

 

Electrical connection

Electrical connection

Electrical connection

Electrical connection    

 
Important: the appliance must be installed by specialised staff. The electrical connection must be carried out 
using the supplied cable, adding an adequate plug on a socket which can take the load factor and voltage 
specific of each model as indicated on the technical data table (see page 17), the plug must be accessible 
when the appliance is installed. It is necessary that the fixed power grid is protected with a single pole switch 
to assure a complete disconnection with a minimum opening between the contacts of 3 mm. Make sure there 
is an efficient grounding, if there isn’t one or it is inefficient you should provide to have a grounding installed 
in compliance with the standards in force. 
 
N.B. The stove heating system is protected by two fuses located inside the main switch behind the stove. 
Always remember to disconnect the power supply before carrying out any maintenance and/or checks! 

Содержание S7

Страница 1: ...Maintenance And Use Manual Pellets Stove Pellets Stove Pellets Stove Pellets Stove...

Страница 2: ...roduct Fair will not be liable in the event of failure to respect these instructions This stove should be used for the purposes for which it was designed and made The manufacturer is excluded from any...

Страница 3: ...s solid combustible materials of b type with forced draft as modern heating appliances are high efficient with colder fumes and a consequent lower draft it is really important that the chimney flue is...

Страница 4: ...atio between the inner sides must be 1 5 and the linked sides must have a minimum radius of 20 mm The section dimensions must be equal to or bigger than the diameter of the fumes waste pipe 8cm Hereun...

Страница 5: ...External air intake External air intake External air intake External air intake We recommend to set an air intake from the outside to have a healthy inner environment The air flow between the outside...

Страница 6: ...e of problem we recommend installing a permanent ventilation grid in a window or near the stove Air intake directly from the outside is compulsory WARNING Use only steel pipes Pipes in synthetic mater...

Страница 7: ...made of stainless steel A316 or porcelain zed minimum thickness 0 5mm with a diameter of 80 mm or 100mm depending on the type of plant see picture 2 pag 4 you can not use pipes made of asbestos cemen...

Страница 8: ...ot use inflammable liquids Pellets are the only combustible material you can use You can find different kind of pellets with different characteristics and quality on sale We recommend to use pellets o...

Страница 9: ...t be installed in isolation with a minimum air space of 15 cm to allow an adequate cooling of the appliance and a good distribution of heat in the domestic environment In compliance with fire preventi...

Страница 10: ...by the moto ventilators keeps the stove temperature low preventing the materials the stove is made of from excessive stress and heating the domestic environment more homogeneously Make sure you period...

Страница 11: ...rol panel Control panel Control panel Control panel Key P1 and P2 when you are setting the temperature they increase or decrease the thermostat parameter from minimum 06 C to maximum 41 C If you keep...

Страница 12: ...stove will immediately go into the ON operating phase it is only possible to jump the startup phase if the smoke temperature detected by the probe is over 55 60 C Below these values after several sec...

Страница 13: ...y when you want to start program 1 2 3 or 4 Pressing P1 and P2 you can choose the wanted parameter UT05 UT06 indicates starting and ending time of the functioning of the stove in program 1 They are ac...

Страница 14: ...er is damaged or disconnected AlAr Sond will appear on display The electronic card stops the electric input to the cochlea blocking the pellets stoking to the brazier and starting the switching off ph...

Страница 15: ...and the stove cool down and disconnect it from electrical power supply Filter cleaning Filter cleaning Filter cleaning Filter cleaning The stove is equipped with a filter against dust which is placed...

Страница 16: ...he obstructed holes Clean also the brazier room from ash left inside The frequency of the cleaning depe depe depe depends on the type of pellets Pay attention to the flame colour if it is red that mea...

Страница 17: ...5 5 12 5 5 12 5 5 11 5 5 11 Average temperature fumes 78 206 C 78 206 C 78 206 C 78 206 C 78 167 C 78 167 C Mass flow fumes 3 3 5 6 g s 3 3 5 6 g s 3 3 5 6 g s 3 3 5 6 g s 3 3 5 0 g s 3 3 5 0 g s Tan...

Страница 18: ...Pellets Stove 18 18 18 18 Wiring diagram Wiring diagram Wiring diagram Wiring diagram...

Страница 19: ...Pellets Stove 19 19 19 19...

Страница 20: ...Pellets don t get to the fire box The tank is empty Cochlea is blocked by a strange object ex Nails Cochlea gear motor is damaged Verify if there is an alarm activated on display ex AlAr dEP AlAr Sic...

Страница 21: ...ce the card cod Com0231 Call a specialised technician The stove is in steady condition the display shows RiS Environment temperature reached Fumes outlet temperature reached The stove works at minimum...

Страница 22: ...necessary to stoke it again and start the stove Replace the thermostat cod Com0238 Call a specialised technician Clean the filter see Maintenance Replace the card cod Com0231 Call a specialised techni...

Страница 23: ...e or of Fair srl discover while doing repairs that the date of installation first startup is not the true one which can be detected from identifying details and other elements in the equipment The pre...

Страница 24: ...number Serial number Serial number Tests carried out Tests carried out Tests carried out Tests carried out Automatic ignition Automatic ignition Automatic ignition Automatic ignition Combustion air mo...

Страница 25: ...ised T Specialised Technical Servicing Centre echnical Servicing Centre echnical Servicing Centre echnical Servicing Centre Work done on Work done on Work done on Work done on Material used Guarantee...

Страница 26: ...ntre Specialised Technical Servicing Centre Specialised Technical Servicing Centre Specialised Technical Servicing Centre Work done on Work done on Work done on Work done on Material used Guarantee YE...

Страница 27: ...Pellets Stove 27 27 27 27...

Страница 28: ...FAIR s r l Via Lago di Costanza 24 36015 Schio VI ITALIA Tel 0445 698000 Fax 0445 698100 e mail info fair europe com http www fair europe com Fair 2009 rev 1 10 10 09...

Отзывы: