Pellets Stove
13
13
13
13
Weekly programming
Weekly programming
Weekly programming
Weekly programming
You can plan the daily starting and switching off of the stove for 7 Days with 4 different programs. Remember
pressing P4 you can exit from any program at any time you wish. The parameters of the clock-thermostat are:
UT01 to set the current date and the use modality (OFF means the exclusion of programming).
UT02 to set the current hour.
UT03 to set minutes.
UT04 to set technical parameters (reserved to technicians).
UT05 to set starting time program 1, with step of 10 min.
UT06 to set switching off time program 1, with step of 10 min.
UT07 to choose the weekdays with program 1 starting.
UT08 to set starting time program 2, with step of 10 min.
UT09 to set switching off time program 2, with step of 10 min.
UT010 to choose the weekdays with program 2 starting.
UT011 to set starting time program 3, with step of 10 min.
UT012 to set switching off time program 3, with step of 10 min.
UT013 to choose the weekdays with program 3 starting.
UT014 to set starting time program 4, with step of 10 min.
UT015 to set switching off time program 4, with step of 10 min.
UT016 to choose the weekdays with program 4 starting.
To verify if the clock-thermostat is working, go to UT01, the indication “Day” means it is activated, “OFF”
means it isn’t.
We explain you now some parameters meaning.
UT01 to set the weekly program on “Day” or deactivate it on “OFF”. Select the weekday from “Day 1”=
monday to “Day 7”= sunday. If UT01 is set on the current day (ex: Day 2 is tuesday) you can then select the
weekday when you want to start program 1, 2, 3 or 4. Pressing P1 and P2 you can choose the wanted
parameter.
UT05-UT06 indicates starting and ending time of the functioning of the stove in program 1. They are
activated when UT01 is on weekly modality.
UT07 this parameter is activated when UT01 is on weekly modality. When program 1 is activated, with P1
you can choose the weekday and with P2 you activate or deactivate the starting of the stove and so on for all
programs.
Example:
Starting
Switching
off
Mon.
(Day1)
Tue.
(Day2)
Wed.
(Day3)
Thu.
(Day4)
Fri.
(Day5)
Sat.
(Day6)
Sun.
(Day7)
Progr. 1
UT05
UT05
UT05
UT05 h
07.00 UT06
UT06
UT06
UT06 h
09.00
ON
ON
ON
ON ON
ON
ON
ON ON
ON
ON
ON ON
ON
ON
ON ON
ON
ON
ON
OFF OFF
Progr. 2
UT08
UT08
UT08
UT08 h
11.00 UT09
UT09
UT09
UT09 h
13.00
ON
ON
ON
ON ON
ON
ON
ON ON
ON
ON
ON ON
ON
ON
ON ON
ON
ON
ON
OFF OFF
Progr. 3 UT011
UT011
UT011
UT011 h
17.00 UT012
UT012
UT012
UT012 h
21.00
ON
ON
ON
ON ON
ON
ON
ON ON
ON
ON
ON ON
ON
ON
ON ON
ON
ON
ON
OFF OFF
Progr. 4 UT014
UT014
UT014
UT014 h
10.00 UT015
UT015
UT015
UT015 h
20.00
OFF OFF OFF OFF OFF
ON
ON
ON
ON ON
ON
ON
ON
Optional remote control
Optional remote control
Optional remote control
Optional remote control
With the remote control it is possible to adjust the heating power, the desired ambient temperature and
switch the apparatus on/off automatically.
To switch on the stove press buttons P1 and P6 simultaneously for 3 seconds; the apparatus will
automatically enter the ignition stage. After the ignition stage it will enter normal operation mode and buttons
P6 and P5 can be used to adjust the heating power. Pressing P1 or P2 will adjust the desired ambient
temperature. To switch off the stove keep buttons P1 and P6 pressed simultaneously for 3 seconds, display
A will show the message “Off”.