* The appliance is not intended for use by young children
or infirm persons without supervision. Young children should
be supervised to ensure they do not play with the appliance.
* The cooktop surface and the inferior part of the range
hood must be at a minimun distance of 65 cm.
* The air sucked can't be vented through or into a duct
used to let out fumes from appliances fed by energy
other than electric power (eg. centralized heating,
radiators, water-heaters, etc.).
* To evacuate the air outlet, please comply with the
pertaining rules given by authorities.
* Provide the room with an adequate aeration when a
cooker hood and appliances fed by energy other than
electric power (gas-, oil-, or coal- stoves, etc.) are used
simultaneously. The cooker hood, when evacuating the
sucked air, could generate a negative pressure in the
room- which can't exceed the limit of 0.04 mbar, in
order to avoid the suck of exhausts deriving from the
heat-source. Therefore the room should be provided
with air-intakes to allow a costant flow of fresh air.
If the rating lable in the range hood shows
the symbol , the appliance is built in class
II
°
and it does not need any earth connection.
If the rating lable in the range hood does not
show the symbol , the appliance is built in
class I
°
and it needs the earth connection.
* When performing the electrical connections on the
appliance, please make sure that the current-tap is
provided with earth connection and that voltage values
correspond to those indicated on the label placed inside
the appliance itself.
* Before carrying out any cleaning or maintenange
operations, the appliance needs to be removed from the
electric grid.
If the appliance is not supplied with a non-separable
flexible cable and plug, or with another device ensuring
omnipolar disconnections from the grid, with an opening
distance between the contacts of at least 3 mm, then
such disconnecting devices must be supplied within the
fixed installation.
If the appliance is supplied with a supply cord and a
plug, the appliance has to be put in a place where the
plug can be reached easily.
* The use of materials which can burst into flames
should be avoided in close proximity of the appliance.
WARNINGS
USES
The appliance is already arranged both for filtering and
for suction performances.
* In its
filtering version
(Fig.1), the air and fumes vented
by the appliance are depured both by a grease filter and
by an active coal filter, and put again into circulation
through the side-grids of the chimney. For this version
an air deflector placed on the superior part of the pipe
and allowing air-recycling is necessary (Fig.1).
* In its
sucking version
(Fig.2), fumes are directly
conveyed outside, through an evacuation duct connected
with the superior part of the wall or the ceiling. Both coal
filter and air deflector are not necessary in this case.
* Before installing the appliance and in order not to
damage the appliance itself, the metal grease filter should
be removed. Such filter can be removed by pushing the
special filter handle toward the back side of the ranger
hood and turning it downwards so as to unfasten it from
its slot (Fig. 3).
Attention: at least two people are needed to perform
the installation.
Before fixing the hood, place the electric feeding properly
into the ornamental pipe and place a hole for air
evacuation in case of a sucking version.
* Suction model
Place the upper plate (Fig. 4.1) on the ceiling. Drill 4
holes, 8 mm each, just next to the slots.
Insert the plastic dowels into the holes (Fig. 4.1-A) and
screw the plate on the ceiling (Fig. 4.1-B). Then fasten
the lower structure (Fig. 6.2) on the hood by making its
holes and the metric-thread screws welded on the fan
support coincide (Fig. 6.1). Insert the washers and nuts
provided (Fig. 6.2-A) and screw with an appropriate
tool.
Connect the drainpipe to the power unit nozzle and fix
securely with a hose clamp.
Insert the upper structure (Fig. 6.3) into the lowest one
and adjust its height as required by matching it with the
cooktop’s minimum height. Tighten the two structures
securely with the screws provided (Fig. 6.3-B).
INSTALLATION
When frying, please pay particular attention to fire
risk due to oil grease. Since it is highly inflammable,
fried oil is especially dangerous. Do not use uncovered
electric grills. In order to avoid possible fire risk, all
instructions for grease-filter cleaning and for removing
eventual grease deposits should be strictly followed.
Содержание SCFB-36 IX
Страница 1: ......
Страница 2: ......
Страница 4: ...Warnings Uses Installation Working Maintenance CONTENTS 4 GB...
Страница 7: ...7 INDEX Attention Version de l appareil Installation Fonctionnement Entretien F...
Страница 10: ...Advertencias Versiones Instalacion Funcionamiento Mantenimiento NDICE 10 E...
Страница 13: ...13 1 2 3 4 Fig 4 3 Fig 4 2 Fig 4 1...
Страница 14: ...14 5 Fig 5 2 Fig 5 1 7 8 9 Fig 6 6 Fig 6 5 Fig 6 4 Fig 6 3 Fig 6 2 Fig 6 1 6...
Страница 16: ...FAGOR AMERICA APPLIANCES DIVISION P O BOX 94 LYNDHURST NJ 07071 PLACE STAMP HERE...
Страница 17: ...17 17...
Страница 18: ...18...
Страница 19: ...19...
Страница 20: ...Mg 90130104021 04 08...