REACH IN REFRIGERATORS AND FREEZERS, ELECTRICAL SPECS
Model
Max.
Amps
HP Voltage
NEMA
Plug
Breaker
Size*
Wire gauge recommended for 2% voltage drop in supply circuits **
40 ft ***
60 ft
80 ft
100 ft
120 ft
140 ft
QR-1
5.6
3.1
1/4
115
220
5-15P
2P+TT
15 amp
10 amp
14 AWG
14 AWG
14 AWG
14 AWG
12 AWG
14 AWG
12 AWG
14 AWG
12 AWG
14 AWG
10 AWG
12 AWG
QR-2
6.9
3.5
1/3
3/8
115
220
5-15P
2P+TT
15 amp
10 amp
14 AWG
14 AWG
12 AWG
14 AWG
12 AWG
14 AWG
10 AWG
12 AWG
10 AWG
12 AWG
10 AWG
12 AWG
QF-1
8.5
4.5
3/4
115
220
5-15P
2P+TT
15 amp
10 amp
14 AWG
14 AWG
12 AWG
14 AWG
10 AWG
12 AWG
10 AWG
12 AWG
8 AWG
12 AWG
8 AWG
12 AWG
QF-2
12.9
6.5
1
115
220
5-15P
2P+TT
20 amp
10 amp
12 AWG
14 AWG
10 AWG
12 AWG
8 AWG
12 AWG
8 AWG
12 AWG
8 AWG
12 AWG
6 AWG
12 AWG
QR-1G
6
3.4
1/4
115
220
5-15P
2P+TT
15 amp
10 amp
14 AWG
14 AWG
14 AWG
14 AWG
12 AWG
14 AWG
12 AWG
14 AWG
10 AWG
12 AWG
10 AWG
12 AWG
QR-2G
7.3
3.9
1/3
115
220
5-15P
2P+TT
15 amp
10 amp
14 AWG
14 AWG
12 AWG
14 AWG
12 AWG
14 AWG
10 AWG
12 AWG
10 AWG
12 AWG
8 AWG
12 AWG
QVR-1
5.6
3.1
1/4
115
220
5-15P
2P+TT
15 amp
10 amp
14 AWG
14 AWG
14 AWG
14 AWG
12 AWG
14 AWG
12 AWG
14 AWG
12 AWG
10 AWG
12 AWG
QVR-2
6.9
3.5
1/3
3/8
115
220
5-15P
2P+TT
15 amp
10 amp
14 AWG
14 AWG
12 AWG
14 AWG
12 AWG
14 AWG
10 AWG
12 AWG
10 AWG
12 AWG
10 AWG
12 AWG
QVF-1
8.5
4.5
3/4
115
220
5-15P
2P+TT
15 amp
10 amp
14 AWG
14 AWG
12 AWG
14 AWG
10 AWG
12 AWG
10 AWG
12 AWG
8 AWG
12 AWG
8 AWG
12 AWG
QVF-2
12.9
6.5
1
115
220
5-15P
2P+TT
20 amp
10 amp
12 AWG
14 AWG
10 AWG
12 AWG
8 AWG
12 AWG
8 AWG
12 AWG
8 AWG
12 AWG
6 AWG
12 AWG
QVR-
1G
5.9
1/4
115
5-15P
15 amp
14 AWG
14 AWG
12 AWG
12 AWG
10 AWG
10 AWG
QVR-
2G
7.3
3.9
1/3
3/8
115
220
5-15P
2P+TT
15 amp
10 amp
14 AWG
14 AWG
12 AWG
14 AWG
12 AWG
14 AWG
10 AWG
12 AWG
10 AWG
12 AWG
8 AWG
12 AWG
QVR-3
11.5
3/4
115
5-15P
15 amp
14 AWG
12 AWG
12 AWG
10 AWG
10 AWG
8 AWG
QVF-3
16.0
3/4
115
5-15P
15 amp
14 AWG
12 AWG
12 AWG
10 AWG
10 AWG
8 AWG
Note:
*Breaker sizes are recommended to protect the equipment by overload; this
breaker only must be dedicated for the equipment.
**If the equipment is installed faraway of the circuit breaker, these are the
wire gauge recommend to connect the appliance; if the distance is higher that
the chart values, please contact an electrician.
***Distance in feet from the breaker or the power supply to the appliance.
Содержание QF-1
Страница 1: ...REFRIGERATORS AND FREEZERS Manual for installation use and maintenance...
Страница 11: ...www Fagorcommercial com PAGE 11 REACH INS OPERATIONAL SERVICE MANUAL Rev JUN 2015...
Страница 21: ...www Fagorcommercial com PAGE 21 REACH INS OPERATIONAL SERVICE MANUAL Rev JUN 2015 7 WIRING DIAGRAMS QR 1 QVR 1...
Страница 22: ...www Fagorcommercial com PAGE 22 REACH INS OPERATIONAL SERVICE MANUAL Rev JUN 2015 QF1 QVF 1...
Страница 23: ...www Fagorcommercial com PAGE 23 REACH INS OPERATIONAL SERVICE MANUAL Rev JUN 2015 QR2 QVR 2...
Страница 24: ...www Fagorcommercial com PAGE 24 REACH INS OPERATIONAL SERVICE MANUAL Rev JUN 2015 QR 1G QVR 1G...