background image

www.Fagorcommercial.com

 

 

PAGE 25 

 

REACH-INS OPERATIONAL SERVICE MANUAL / Rev.JUN. 2015

 

8

 

WARRANTY 

 

 

AS OF APRIL 1, 2014 

 

Three  Years  Parts  &  Labor  Warranty:  Fagor  Commercial,  Inc.  (“Fagor”)  Warrants  to  the  fist-end-user 
purchaser (the “User”) that the Fagor brand equipment sold hereunder, except for parts and accessories 
which carry the warranty of a supplier (the “Equipment”) will be free from defects in material and factory 
workmanship under normal conditions of use and maintenance and upon proper installation and start-up 
in  accordance  with  the  User  manual  supplied  with  each  Fagor  unit.  The  obligation  of  this  warranty  is 
covered  by  Fagor  for  a  period  of  three  (3)  years  from  the  date of  installation  (Warranty  commencement 
date), but in no event to exceed thirty-nine (39) months from the date of shipment from Fagor. Warranty is 
Not Transferable. 

 

Warranty  Coverage:  If  there  is  a  defect  in  material  or  factory  workmanship  covered  by  this  Warranty 
reported  to  Fagor  during  the  period  the  applicable  Warranty  is  in  force  and  effect,  Fagor  will  repair  or 
replace,  at  Fagor’s  option,  that  part  of  the  Equipment  that  has  become  defective  and  will  cover 
reasonable  labor  cost  within  the  corresponding  warranty  period  of  time. Fagor  shall  bear  all  reasonable 
labor costs in connection with the installation of these replacement parts, provided that, the installation is 
conducted by Fagor or its authorized representative. Charges for warranty travel time round trip, total two 
(2)  hours  or  up  to  100  miles  total.  Any  charges  exceeding  those  stated  herein  must  have  prior 
authorization  by  Fagor.  In  case  Fagor  deems  the  equipment  non-repairable,  said  equipment  will  be 
replaced  and  the  replacement  unit(s)  will  carry  the  same  warranty  p

eriod  from  the  original  unit’s 

installation date (original Warranty commencement date).  

 

Additional Two Year Compressor Part Warranty: In addition to the warranty set above, Fagor warrants the 
sealed compressor (part only) for an  additional two (2)  years  based on the  original installation date,  but 
not to exceed thirty-nine (39) months after shipment from the manufacturer. This warranty is for defects, 
both in  workmanship and  material, under the  normal and proper use and maintenance service. The two 
(2)  year  extended  warranty  only  applies  to  sealed  parts  of  the  compressor  and  does  not  apply  to  any 
other  part  or  component,  including,  but  not  limited  to  cabinet,  temperature  control,  refrigerant,  motor 
starting equipment, fan assembly, or any other electrical or mechanical component. 

 

 

Exclusions  from  and  Conditions  to  Warranty  Coverage:  This  Warranty  does  not  cover  parts  or 
accessories, which (a) carry the warranty of a supplier or (b) are abused. Application of this Warranty is 
further conditioned upon the following:  

 

 

Installation:  The  Equipment  must  be  properly  installed  in  accordance  with  Fagor’s  installation 
procedures and by a professional technician.  

 

 

No  Alteration:  The  Equipment  must  not  have  been  modified  or  altered  from  its  condition  at  the 
date of original installation.  

 

 

Use:  FAGOR  EQUIPMENT  IS  NOT  DESIGNED  FOR  PERSONAL,  FAMILY,  OR  HOUSEHOLD 
PURPOSES, AND ITS SALE FOR SUCH PURPOSES IS NOT INTENDED. IN THE EVENT THE 
EQUIPMENT  IS  SO  USED,  THIS  WARRANTY  SHALL  BE  NULL  AND  VOID,  AND  THE 
EQUIPMENT  IS  SO  USED,  THIS  WARRANTY  SHALL  BE  NULL  AND  VOID,  AND  THE 
EQUIPMENT SHALL BE DEEMED TO HAVE BEEN SOLD “AS IS-WHERE IS” WITHOUT ANY 
WARRANTY OF ANY KIND, INCLUDING WITHOUT LIMITATION ANY WARRANTY OF TITLE, 
NON-INFRINGEMENT, MERCHANT-ABILITY OR FITNESS FOR A PARTICULAR PURPOSE. 

 
 

Содержание QF-1

Страница 1: ...REFRIGERATORS AND FREEZERS Manual for installation use and maintenance...

Страница 2: ...6 3 3 DATA PLATE 7 3 4 INSTALLATION OF CASTORS OR OPTIONAL LEGS 7 3 5 LEVELING 9 3 6 ELECTRICAL CONNECTIONS 9 3 7 SHELVING INSTALLATION 10 4 OPERATION 10 4 1 ELECTRONIC CONTROL 10 4 2 OTHER FUNCTIONS...

Страница 3: ...aterial until inspection has been made Contact the dealer through which you purchased the unit Check the compressor compartment thousing and visually inspect the refrigeration package Be sure lines ar...

Страница 4: ...3 1666 11 3 R 134a 295 QR 2 49 6 2104 13 4 R 134a 475 QF 1 23 3 2493 16 6 R 404A 295 QF 2 49 6 3644 21 5 R 404A 475 QR 1G 23 3 1666 11 3 R 134a 295 QR 2G 49 6 2104 13 4 R 134a 475 QVR 1 21 3 1666 11 3...

Страница 5: ...QVR 1 5 6 3 1 1 4 115 220 5 15P 2P TT 15 amp 10 amp 14 AWG 14 AWG 14 AWG 14 AWG 12 AWG 14 AWG 12 AWG 14 AWG 12 AWG 10 AWG 12 AWG QVR 2 6 9 3 5 1 3 3 8 115 220 5 15P 2P TT 15 amp 10 amp 14 AWG 14 AWG 1...

Страница 6: ...THE MACHINES NEEDS TO BE INSTALLED 2 FEET AWAY FROM ANY HEAT SOURCES The unit should not be installed under ambient temperatures higher than 100 F If the relative humidity is higher than 60 the door...

Страница 7: ...The data plate is essential to identify the particular features of your machine and it is of great benefit to installers operators and maintenance personnel It is recommended that in the event the da...

Страница 8: ...shims between the castor and the frame rail Install the desired number of shims Make sure the slot of the shim is in contact with the threaded stem of the castor FIG 2 If more than one shim is used t...

Страница 9: ...l code or the National Electrical Code to be sure unit is connected to the proper power source Verify correct incoming voltage according to the Data Plate information Do not under any circumstances cu...

Страница 10: ...rly 4 OPERATION 4 1 ELECTRONIC CONTROL After connecting your unit turn ON rocker switch located next to the controller The display will light up showing the temperature inside the unit Also the compre...

Страница 11: ...www Fagorcommercial com PAGE 11 REACH INS OPERATIONAL SERVICE MANUAL Rev JUN 2015...

Страница 12: ...hanging the set point of the temperature on the controller The unit comes with a factory default set point 8 F Freezers 32 F Refrigerators These set values will make the unit perform at its maximum ca...

Страница 13: ...anging the reading temperature from F to C To change the reading of the temperature from F to C or vice versa you need access to the programming mode in the controller To do this press and hold the SE...

Страница 14: ...exit manual defrost hold the DOWN button arrow for 5 seconds The snow flake icon will turn off Wait 2 minutes for the compressor to start Note If the equipment doesn t reach the temperature first ver...

Страница 15: ...rs Type F parameters include the set point differential temperature monitoring interval interval between defrosts end defrost temperature dripping time alarm thresholds alarm bypass times etc See the...

Страница 16: ...the Parameter belongs to see the table below and the parameter table 5 Press the SET button to display the value of the parameter 6 Press UP DOWN until reaching the desired value 7 Press Set to tempor...

Страница 17: ...y food products have an acidic content which can deteriorate the stainless steel finish Be sure to clean ALL food products from any stainless steel surface Failure to do so will result in spots and ru...

Страница 18: ...tom panel 5 3 GASKET Gaskets require regular cleaning to prevent mold and mildew build up and to keep the elasticity of the gasket Gasket cleaning can be done with the use of warm soap and water Avoid...

Страница 19: ...with the drain hose inside of the pan Units installed in a humid environment will produce large amounts of water in the drain pan This is NOT a malfunction of the unit It is the customer s responsibil...

Страница 20: ...e maximum level mark located on the internal wall of the unit f If FREEZER check that the temperature is not Celsius C g Check that the gasket is in good condition and door is sealed h Check that the...

Страница 21: ...www Fagorcommercial com PAGE 21 REACH INS OPERATIONAL SERVICE MANUAL Rev JUN 2015 7 WIRING DIAGRAMS QR 1 QVR 1...

Страница 22: ...www Fagorcommercial com PAGE 22 REACH INS OPERATIONAL SERVICE MANUAL Rev JUN 2015 QF1 QVF 1...

Страница 23: ...www Fagorcommercial com PAGE 23 REACH INS OPERATIONAL SERVICE MANUAL Rev JUN 2015 QR2 QVR 2...

Страница 24: ...www Fagorcommercial com PAGE 24 REACH INS OPERATIONAL SERVICE MANUAL Rev JUN 2015 QR 1G QVR 1G...

Страница 25: ...ill be replaced and the replacement unit s will carry the same warranty period from the original unit s installation date original Warranty commencement date Additional Two Year Compressor Part Warran...

Страница 26: ...waived unless submitted by the User to Fagor within 30 days after the date the User discovered or should have discovered the claim In connection with all claims under this Warranty Fagor will have the...

Страница 27: ...n deliveries that are beyond our control Damaged Merchandise Inspect shipment for any damage before accepting it If damaged open and inspect the contents with the carrier Any damage should be noted an...

Страница 28: ...w Fagorcommercial com PAGE 28 REACH INS OPERATIONAL SERVICE MANUAL Rev JUN 2015 Fagor Commercial Inc 13105NW 47thAve Miami Fl 33054 Tel 305 7790170 Fax 305 7790173 1 866 GO FAGOR www fagorcommercial c...