16
1.- INSTALLATION
1.1.- Installation diagrams
See Fig.1
1.2.- Positioning
Level and adjust the height of the appliance. (Fig. 2)
1.3.- Water connection
−
To be done as shown in figures 3 or 4.
−
Dynamic pressure necessary during rinsing: 2 - 4 Kg./cm
2
(3.5
÷
5 Kg./cm
2
).
−
With mains pressures of less than 2 Kg/cm
2
(3.5 Kg./cm
2
)., install an electric pressure
pump. (Fig.4).
1.4.- Drainage
a) Fix the drain hose as shown in Fig.5.
b) Fit a siphon pipe to prevent bad smells.
1.5.- Electrical connection
−
For access to the connection strip (R), (Fig. 6 and Fig. 1), remove the cover (T) and the
rear panel (P). Connect the strip as shown in figure 6. Fix the sheathed cable in (E), leave
enough cable to remove the electrical panel from the front.
−
Fit a general switch (I) independent of the appliance with a distance between contacts
equal to or more than 3 mm.
−
The machine must be earthed.
1.6.- Technical specifications
Power(Kw)
MODEL
H. element
Max
Water inlet
pressure
Supply
voltage
Drum
Tub absorb.
Basket
(mm)
Cycle
duration
Min.
Tub
capacity
(l)
Rinse water
consumpt
(l)
Net
weig
(Kg)
LVR-10
LVC-12
1
34
LVC-15
2÷4 Kg/cm²
(28÷56psi)
LVC-15D
3.5÷5
Kg/cm²
(42÷70psi)
2,4
2,66
Ø
350x350
11
2
36
LVC-21
2÷4 Kg/cm²
(28÷56psi
LVC-21D
3.5÷5
Kg/cm²
(42÷70psi)
2 MAX.
(Adjustable)
39
LVC-21B
2÷4 Kg/cm²
(28÷56psi
220
-240V
- 1N
(50/60Hz.)
2,8
2
3,06
400x400
2
(Fixed)
15
2,5
4
12
Содержание LVC-12
Страница 5: ...4 ...
Страница 7: ...6 LVC 21B 2 4 Kg cm 28 56psi 2 Fijo 42 ...
Страница 11: ...10 ...
Страница 13: ...12 LVC 21D 3 5 5 Kg cm 42 70psi LVC 21B 2 4 Kg cm 28 56psi 2 Fixe 42 ...
Страница 18: ...17 ...
Страница 23: ...22 LVC 21B 2 4 Kg cm 28 56psi 2 Fest 4142 ...
Страница 28: ...27 LVC 21B 3 5 5 Kg cm 42 70psi 2 Fisso 421 ...