Important
Before capturing data for an accuracy graph, a home
search must be carried out
because the compensation will
not be applied until the home search is done. To use this
compensation, it is recommended to force a home search on
power-up.
The maximum amount of error that may be compensated
corresponds to a slope of ± 3mm/m.
Pressing the Edit button displays a table with 105 points and
their corresponding error values.
Error to be compensated = Master's actual position -
displayed position
There is no need to use all the points. The compensation point must have at least one point with no error
(error 0).
Different options are offered when the Function button is pressed:
* Exit:
To exit the screen saving the data.
* Draw Graph:
Draws a graph with the points and errors entered. It is
recommended to check the graph to detect possible mistakes
made when entering data.
4.6.4
Test mode
It may be used to know system information such as software version, hardware version, software burning
date, etc.
Pressing the
Test
key displays the software and hardware versions, software recording date, checksum,
error history, etc.
Pressing
Test
again offers the chance to run different tests that are very useful for troubleshooting the
DRO itself or the encoder.
The Test mode is for the installer only and the access is protected with a password.
Password:
231202
Edit
Exit
Function
Draw Graph
Function