![Fagor Innova 40i Скачать руководство пользователя страница 25](http://html1.mh-extra.com/html/fagor/innova-40i/innova-40i_installation-and-operation-manual_537539025.webp)
40i - Installation/Operation - DRO installation - (24/40)
4.4
General technical characteristics
- Universal Power Supply between 100V AC and 240V AC ±10 % at Mains frequency between 45 Hz and
400 Hz. Between 120 V DC and 300 V DC. Maximum power consumed 25 VA. It withstands power
outages of up to 20 milliseconds.
- 10-year memory backup of installation parameters when the unit is off.
- The operating temperature inside the DRO enclosure must be between 5 ºC and 45 ºC (41 ºF and 113
ºF).
- The storage temperature inside the DRO enclosure must be -25 ºC and +70 ºC (-13 ºF and 158 ºF).
- Maximum relative humidity: 95 % non condensing at 45 ºC (113 ºF).
- Front Panel Sealing: IP54 (DIN 40050), Rear panel: IP4X (DIN40050) except for built-in models in which
case is: IP20.