·80·
Remote modules
CNC 8060
CNC 8065
5.
(R
EF
: 1402)
RIOW REMOTE MODULES.
(CANOPEN
PROTOCOL).
Start the module up, the LED blinks orange until it changes to red. If the module is
successfully initialized, the LED changes to green. If the module detects a problem the LED
keeps blinking red. The module shows the error code, cyclically, by three blinking sequences.
• The first blinking sequence (10 Hz) indicates that there are errors at the node.
• After a pause, the module offers the second blinking sequence (1 Hz). The number of
blinks indicates the error code.
• After a longer pause, the module offers the third blinking sequence (1 Hz). The number
of blinks indicates the type of error.
Error 1: Hardware and configuration error at the node.
Blinking orange.
The module is in the initializing stage.
Blinking red.
Data bus error.
Cyclic red blinking.
Error code.
Type.
Description.
Solution.
1
Overflow at the internal data memory of
the module.
Remove power from the node, reduce the
number of modules and apply power to the
node again. If the error persists, replace the
leading (first) module.
2
Wrong I/O module at the node.
Replace wrong module. If the error persists,
update the firmware of the leading (first)
module. To locate the wrong module, repeat the
following sequence as often as necessary.
• Remove power from the node, place the
end module in the middle of the node and
apply power to the node again.
• If the error persists, remove power from the
node again, place the end module in the
middle of the first half of the node and apply
power to the node again.
• If there are no errors, remove power from
the node again, place the end module in the
middle of the second half of the node and
apply power to the node again.
If there is only one I/O module left in the node,
that module will be the wrong one.
3
Checksum error in EEPROM data.
Remove power from the node, replace the
leading module and apply power to the node
again.
4
Error while writing EEPROM.
Remove power from the node, replace the
leading module and apply power to the node
again.
5
Error while reading EEPROM.
Remove power from the node, replace the
leading module and apply power to the node
again.
6
The configuration of the I/O modules
has changed after a reset.
Initialize the module by removing power and
applying it again.
7
Reserved.
8
Timeout error in the EEPROM.
Remove power from the node, replace the
leading module and apply power to the node
again.
9
Reserved.
Led I/O.
Meaning.
Содержание CNC 8060
Страница 1: ...Ref 1402 8060 8065 CNC Remote modules...
Страница 6: ......
Страница 8: ......
Страница 10: ......
Страница 12: ......
Страница 16: ......
Страница 20: ......
Страница 22: ......
Страница 147: ...Remote modules CNC 8060 CNC 8065 REF 1402 147...
Страница 148: ...148 Remote modules CNC 8060 CNC 8065 REF 1402...