
Remote modules
CNC 8060
CNC 8065
5.
(R
EF
: 1402)
·75·
RIOW REMOTE MODULES.
(CANOPEN
PROTOCOL).
5.5
RIOW-CANOPEN-ECO module. Leading (first) module.
The RIOW-CANOPEN-ECO module must be present in all the groups and must be the first
module of the group. This module is in charge of managing the internal bus of the group and
connecting the group to the CAN bus of the system.
Power the module with an external 24V DC (between -15% and +20%) regulated power
supply.
STOP
RUN
TX
RX
I/O
Overflow
56
78
12
34
ON
24V 24V 0V 0V
Power supply.
CAN bus connection.
Address (node) of the element
and transmission speed.
Locking disk.
Status indicator LED's.
Unlocking tab.
Содержание CNC 8060
Страница 1: ...Ref 1402 8060 8065 CNC Remote modules...
Страница 6: ......
Страница 8: ......
Страница 10: ......
Страница 12: ......
Страница 16: ......
Страница 20: ......
Страница 22: ......
Страница 147: ...Remote modules CNC 8060 CNC 8065 REF 1402 147...
Страница 148: ...148 Remote modules CNC 8060 CNC 8065 REF 1402...