·38·
Remote modules
CNC 8060
CNC 8065
3.
(R
EF
: 1402)
RIO70
REMOTE MODULES. (C
ANFAGOR PROTOCOL).
3.6.1
Elements (connectors).
Connector ·X1·.
Not being used from software version V01.10 on. Previous versions allowed connecting 2
probes of 5 V DC or 24 V DC.
Connectors ·X2· & ·X3· & ·X4· & ·X5·. Feedback inputs (differential TTL and sinusoidal
1 Vpp).
4 15-pin female SUB-D HD type connectors.
To connect feedback devices with differential TTL or 1 Vpp sinusoidal signals. See
"3.8 Feedback inputs. Technical characteristics and connection."
(*) Pin ·15· is offered for compatibility. We recommed to connect the cable
shield to the connector housing at both ends.
Pin.
Signal.
Function.
1
A
Feedback signals.
2
/ A
3
B
4
/ B
5
I0
Reference signals.
6
/ I0
7
AL
Feedback alarm.
8
/ AL
9
+5 Vdc
Voltage supply for the feedback system.
10
- - -
11
GND
0 V reference signal.
12
- - -
13
- - -
14
- - -
15
Chassis(*)
Shield.
11
15
6
10
1
5
Содержание CNC 8060
Страница 1: ...Ref 1402 8060 8065 CNC Remote modules...
Страница 6: ......
Страница 8: ......
Страница 10: ......
Страница 12: ......
Страница 16: ......
Страница 20: ......
Страница 22: ......
Страница 147: ...Remote modules CNC 8060 CNC 8065 REF 1402 147...
Страница 148: ...148 Remote modules CNC 8060 CNC 8065 REF 1402...