·50·
Remote modules
CNC 8060
CNC 8065
4.
(R
EF
: 1402)
RIO5 REMOTE MODULES.
(CANOPEN
PROTOCOL).
4.2
Power supply.
The power supply must be powered at 24 Vdc and connected to the CAN bus of the system.
There are two power supply models.
• Power supply with 24 digital inputs and 16 digital outputs.
• Power supply with 4 analog inputs, 4 analog outputs and 2 inputs for temperature
sensors.
Connector ·X1·.
Power supply.
Power supply with digital inputs and
digital outputs.
GND
L
SH
SH
H
X3
GND
L
SH
SH
H
X2
CAN
POWER
24I/16O
ERR
RUN
X4
X5
X6
X7
I13
I24
I1
I12
GND
O16
O9
+24V
GND
O8
O1
+24V
X1
CHS
GND
+24V
4
0
1
F
E
D
C
B
A
9
8
7
6
5
3
2
ADDRESS
SPEED
1
0
LT
1
0
CAN bus. ·SPEED· selector.
CAN bus transmission speed.
CAN bus. ·ADDRESS· selector.
Address (node) of the element within the CAN
bus.
CAN bus. Leds.
Status indicators.
CAN bus. ·ST· selector.
Line terminating resistor.
CAN bus. Connector ·X2·.
CAN bus connection.
CAN bus. ·X3· connector.
CAN bus connection.
Connector ·X4·.
8 digital outputs.
Connector ·X5·.
8 digital outputs.
Connector ·X6·.
12 digital inputs.
Connector ·X7·.
12 digital inputs.
Содержание CNC 8060
Страница 1: ...Ref 1402 8060 8065 CNC Remote modules...
Страница 6: ......
Страница 8: ......
Страница 10: ......
Страница 12: ......
Страница 16: ......
Страница 20: ......
Страница 22: ......
Страница 147: ...Remote modules CNC 8060 CNC 8065 REF 1402 147...
Страница 148: ...148 Remote modules CNC 8060 CNC 8065 REF 1402...