SAFETY ACCESSORIES -
BAYT 980
Elpro 980
980
GB
LOW VOLTAGE ELECTRIC CONNECTIONS
Radio Contact:
COMMON
RADIO
CONT
ACT
7
3
- Open/Close (standard)
- Any new pulse reverses direction
- Step by step
Photo cells or Magnetic loops:
1
DIP-SWITCH 1:
ON: Photo cells or loop stop beam on Opening
reverse on Closing once Obstacle is removed
OFF: Photo cells or loop do not stop beam on
Opening, reverse on Closing in case of
an obstacle
9
DIP-SWITCH 9:
ON: On Dwell , automatic mode
(Dip-Switch 3=ON) the beam lowers on
crossing the 2nd pair Photocells or loop
OFF: No beam lowering on crossing 2nd pair Photo cells
Keyswitch:
2
ON: No reversing on Opening
OFF: Any pulse reverses travel direction
DIP-SWITCH 2:
ON: Step by step, stop in between
5
OFF: Standard operations
DIP-SWITCH 5:
Limit Switches:
2899
Motor:
Flashing
lamp:
ELECTRICAL POWER CONNECTIONS
FADINI
l'apricancello
Power Supply:
BOARD POWER SUPPLY
230V
±
10% 50Hz
SINGLE-PHASE
230 VOLT
240 VOL
T
4565
VOLTAGE CUT
OFF SWITCH
OFF: No pre-flashing
4
ON: Pre-flashing
DIP-SWITCH 4
ON: Lamp out of service on Dwell
time, automatic mode
OFF: Lamp flashes on Dwell time
automatic mode
8
Deadman (hold on switched) control:
Open and Close operations are achieved by "holding a switch on" (no relay self-holding is
involved) therefore a physical attendance is required to keep the barrier opening or closing until
either the button or key is released.
DIP-SWITCH 6
6
ON= Deadman control
OFF= Standard operating mode
3
DIP-SWITCH 3
ON= Automatic Closing
OFF= No automatic Closing
Semi-automatic mode
Automatic / Semi-automatic:
External Time Clock (Optional):
DIP-SWITCH N
°
3=ON Automatic Closing
3
ON= Automatic closing
OFF= No automatic closing
Semi-automatic mode
FUNCTIONS
4
3
COMMON
COMMON
OPEN
NO
External Clock
TIME CLOCK: Elpro 980 allows a standard time clock to be connected to it .
Connections: parallel connect the NO contact of the clock to the terminal n
°
4 OPEN and n
°
3 COMMON, and set the board
to the automatic mode by Dip-Switch n
°
3=ON
How it works: Set the clock to the required opening time. At the pre-set time the barrier is automatically opened and held
open (the lamp goes off and the led flashes twice shortly and a longer pause follows). Any further pulsing (even by remote
control) is not accepted by the system until the time pre-set by the clock has expired. On expiring, and after the pre-set
dwell time, the barrier is closed automatically.
DWELL TIME
from 0 to 207s
-
+
BAYT 980
Oleodinamica
12
1
2
CONTACT FOR
PHOTO CELLS OR
MAGNETIC LOOPS
24V OUTPUT (MAX. LOAD 350mA:
N
°
2 PAIRS PHOTO CELLS
N
°
1 RADIO RECEIVER)
13
3
4
5
6
STOP
COMMON
OPEN
CLOSE
NO
NO
NC
8
9 10
LIMIT SWITCH
CLOSING
LIMIT SWITCH
OPENING
LIMIT SWITCH
COMMON
18
SINGLE-PHASE
MOTOR M
M
COMMON
16
17
FLASHING LAMP 230V
25W max
20
19
NEUTRAL
LIVE
21
22
DIP-SWITCH 8
MOTOR RUN TIME:
no motor run TRIMMER
is fitted, run time is controlled through the
limit switches and is factory preset at 25 sec.
max. (Max. time required is 19 sec. BAYT 980
with 8 m beam and skirt)
The board is supplied with power after connecting the
cut off switch to the 230V 50Hz mains
Automatic cycle: on pulsing to open, the beam rises and stays open (up position) on Dwell as long as the time
set on trimmer T2 expires, then it lowers automatically
Semi-automatic cycle: on pulsing to open, the beam rises. Another pulse is needed for the beam to lower.
Made in Italy
the gate opener
Drw. N. 5755
page 8