pag 19
Key selector:
Photocell and
Safety edge:
1
DIP-SWITCH 1:
ON
: stopped in opening and inverts in
closing or with obstacle removed
OFF:
not stopped in opening and inverts in
closing or in presence of obstacle
Output for a possible automation status warning
lamp:
Warning Lamp
On
= Gate Open
Warning Lamp
Off
= Gate Close
Flashing at
0,5s (fast)
= closing movement
Flashing at
1s (normally)
=opening movement
Flashing at
2s (slowly)
= automation stopped
Warning Lamp
Output 24V- 1W:
Radio contact:
Connecting any NA contact between the two
terminals one may obtain upon each
impulse:
- Only opening:
Dip 2=ON e Dip 5=OFF
- Reverse direction on each impulse
Dip 2=OFF e Dip 5=OFF
- Step by Step: Open-Stop-Close-Stop
Dip 2=OFF e Dip 5=ON
ON
:
Does not reverse and does not stop in opening
OFF
: In opening always stops and inverts
2
ON
: Step by step with intermediate stop
OFF
: Reverses direction on every impulse
5
DIP-SWITCH 2 and 5 (MUST NOT ever be
simultaneously ON):
All of the NC contacts on the safety
accessories such as photocells receivers
and Edges must be connected in series to
the 1 and 2 terminals
ELECTRICAL CONNECTIONS CONNECTED TO THE TERMINALS AND THEIR FUNCTIONS
Accessory
Electrical connections
Dip - Switch and LED signals of their functions
contact NA and NC to be connected to their
respective terminal boards or button panels.
All thepossible configurations are attached to
their respective command accessories
FA
D IN
I
Output 24V:
FA
D IN
I
FA
D IN
I
Astro 43
FA
D IN
I
NC
NC
1 2
3 4 5 6
NC
OPEN
CLOSE
ST
OP
COMMON
RADIO
CONTACT
COMMON
3
7
11 12
-
+
OUTPUT 24Volt dc for flasher
10
9
+ -
OUTPUT24V for max load:
n°2 pairs of photocells
n°1 Radio receiver
n°1 Led selector Chis 37 / Chis E37
All the instructions are attached to their
respective command flashing accessories
Flashing at
24Volt dc:
DIP-SWITCH 4 e 8
ON
: Pre-flashing before opening
OFF
: without pre-flashing
4
ON
: Flasher desactivated during pause in
automatic operation (with
Dip 3= ON
)
OFF
: Flashes during pause in automatic
Operation (with
Dip 3= ON
)
8
FADINI
l'apricancello
13 14
-
+
L2 On
= no present obstacle, it turns off with
present obstacle
L4 On
= no contact OPEN, it lights up with
each opening impulse
L5 Off
= nessun contatto CLOSE, it lights up
with each closing impulse
L6 On
= STOP contact closed, turn off at
each stop contact
L7 Off
= no RADIO contact, lights on at every
impulse of radio contact
FADINI
FA
D IN
I
Output 24V cc/ca
for DSA control :
24V Output to power the photocell trasmitters(
connected in parallel ) for the
DSA
control:
Autotest safety device= before each movement of
the gate, if this function is enabled, there is check of
all of the safety devices because they are free, in
the event that this is not so, the gate will not start
up.
ON
: DSA control of the photocells
OFF
: No DSA control of the photocells
10
DIP-SWITCH 10
TX
FADINI
TX
Junior 624 - 24V dc
meccanica
FADINI
Elpro 62
GB
8 9
-
+
Содержание Elpro 62
Страница 6: ...pag 5 Fig 5 Fig 6 60mm 60mm Fig 7 Fig 8 60mm 60mm...
Страница 7: ...pag 6 Fig 9 96mm 96mm 60mm 96mm 60mm 2mm Fig 10 96mm 60mm 96mm 60mm 2mm 22x8 6 5 M8 96mm...
Страница 8: ...pag 7 Fig 11 Fig 12 1 2 3 1 2 3 Fig 13...
Страница 18: ......
Страница 19: ......