background image

9

8

PIC. 14

PIC. 13

CONNECTION DIAGRAM FOR SWING GATES

 

13

 

exp

TERMINAL BOARD

STOP

OPEN
CLOSE

E. CONNECTIONS
KEYSWITCH SECH 15

STOP N.C. CONT

A

C

CLOSE N.O. CONT

ACT

OPEN N.O. CONT

ACT

COMMON

1 2 3 4 5

6 7 8 9 10 11 12 13 14 15

16 17 18

7    8

M1

M2

19 20 21 22 23 24 25

12,5

µ

F

12,5

µ

F

1

2

3

4

5

6

7

8

9

ON

OFF

1   2   3   4   5   6   7   8

ON

RADIO CONTROL

PLUG-IN CARD SUPPORT

ON TO “0” THE DELAY

IS OUT OF SERVICE

DWELL TIME

MOTOR RUN
OPEN & CLOSE TIME

CAPACITORS

MICROPROCESSOR

DIP-SWITCH

TERMINAL FOR
CONNECTIONS TO
PUSH BUTTONS PULIN 3

1 AMP. FUSE
24 V OUTPUT
TERMINALS 12-13

TIMER SWITCHES

FUSE

630 mA

FUSE 5 AMPS

1 st

 CHANNEL

24 V OUTPUT

Should more pairs of photocells be required

than the recommended quantity

, fit an auxiliary

transformer outside the control box.

= PHOTOCELLS 2

nd

 P

A

IR =

Inside photocells N.C. cont

act

If obstracted, they prevent the ga

tes from opening

reverse ga

te direction during close cycle

N.C. CONT

ACT

PHOTOCELLS

COMMON

OPEN SWITCH N.O. CONT

ACT

CLOSE SWITCH N.O. CONT

ACT

STOP SWITCH N.C. CONT

ACT

RADIO CONT

ACT N.O.

COMMON

VOL

TAGE OUTPUT

ELECTRIC LOCK SUPPL

Y

24 V INDICA

TOR - 3 W max.

24 V

OUTPUT A.C.

Max permitted load:

2 pairs photocells

1 radio receiver

COMMON

COMMON

230 V FLASHING LAMP

25 W max.

230 V SINGLE-PHASE

SUPPL

Y VOL

TAGE

ELECTRIC MOTORS
SINGLE-PHASE

NOTE WELL: For special applications, ie. to switch
on lights - CCTV etc., SOLID STATE RELAYS are
recommended to be used only. Standard relays
would affect the micro-processor.

NOTE WELL: THIS PANEL IS TESTED TO OPERATE GATES ONLY
THROUGH FADINI ACCESSORIES. NO GUARANTEE FOR
ACCESSORIES OF OTHER MAKE OR SPECIAL APPLICATIONS.

ALL OPERATIONS

OPEN, CLOSE AND

REVERSE

RADIO CONTACT

LEAF DELAY
TIMER CLOSE

Drwg. No. 

1643

 P.C. BOARD

LED No. 1 - It switches on when voltage is supplied

OPEN

STOP

CLOSE

N.O.

N.C.

N.O.

3

4

5

6

26 27 28 3

CONNECTION TO THE “PULIN 3” PUSH
BUTTONS WITH STATUS INDICATION LEDS.

0

FLASHING LAMP

630 mA FUSE

SAFETY CONT

ACT N.C.

ELECTRICAL WIRING DIAGRAM OF THE ELECTRONIC
PROGRAMMER

Once the connections have been made, do the first switching
test through the control panel. Set the motor run timer so that
the motor is allowed to run 4 - 5 seconds more than the gates.
Set the other timers to meet the site requirements. Set DIP switch
B No. 3 to 

automatic

 (ON): on pulsing to 4 - 8 the gates must be

operated as pre-set, ie. opening and only after the dwell time,
closing. Adjust the times through the respective timers. (See No.
07, 08 and 09 drwg. No. 1643).
With DIP switch "B" No. 3 to 

semiautomatic

 (OFF) one pulse opens

the gates, a second pulse to 5 - 8 is needed to close the gates.
Any one pulse to 7 - 8 will open, close or reverse the gates
independently from the operation being performed. It is
recommended to carefully read the instructions in the control
box to have all the functions performed correctly.

The 6 LEDs on the P.C. board indicate the following:

Led No. 1 It switches on when voltage is supplied
Led No. 2 Photocells - Normally on. It switches off when the

photocells are obstructed

Led No. 3 Open - It switches on when the respective switch is

activated

Led No. 4 Close - It switches on when the respective switch it

activated

Led No. 5 Stop - Normally on. it switches off when the respective

switch is activated

Led No. 6 Radio - It switches on whenever a pulse is given, either

from remote control, keyswitch or push buttons.

3    4

To perform the electrical work, connections are as per diagrams on pages 8-9. Once the connections have been made, adjust the
switches in the control box so that the sequence of operations occurs as pre-set. Set DIP switch 3 on automatic and check if the working
times meet your requirements. On semiautomatic mode, one pulse opens the gates, a second pulse is needed to close the gates.

The below diagram is general for an application of the operator and the complementary accessories which are supplied with the unit.

1 - STEMMED AERIAL A 43
2 - LAPI 2 FLASHING LAMP
3 - 230 V - 50/60 Hz MAINS SWITCH WITH
     MAGNETIC-THERMAL DIFFERENTIAL TYPE 0.03 A
      (beyond 100 m distance 2.5 mm Ø cables are recommended)
4 - RADIO RECEIVER CARD A 43/2R
5 - ELECTRONIC PROGRAMMER TYPE ELPRO 13 exp
6 - JUNCTION BOX
7 - WALL PUSH BUTTONS PULIN 3 (INSIDE HOME)
8 - POST WITH PHOTOCELL RECEIVER TYPE DIFO 33

PLEASE NOTE: Should the electric motors
fail to start properly because of power
shortage, connect some extra 12.5 

µ

F

capacitors to the phase and common
terminals as shown in pic. 16.

9 -   RADIO TRANSMITTER TYPE A43/ 2TR
10 - KEYSWITCH TYPE SECH 15
11 - ELECTRIC LOCK
12 - PHOTOCELL TRANSMITTER DIFO 33. OUTSIDE
13 - RIGHT-HAND OPERATOR TYPE APROLI 280 BATT
14 - PHOTOCELL RECEIVER TYPE DIFO 33 OUTSIDE
15 - LEFT-HAND OPERATOR TYPE APROLI 280 BATT
16 - MECHANICAL LATCH
17 - POST WITH PHOTOCELL PROJECTOR TYPE DIFO 33

PIC. 15

PIC. 16

230 Volt
MAINS SWITCH

ALL THE ELECTRICAL EQUIPMENT MUST BE EARTH CONNECTED

1

2

3

4

5

6

7

6

17

14

15

16

10

11

12

13

8

9

16 17 18 19 20 21 22 23

COMMON M1

PHASE M1

PHASE M1

COMMON M2

PHASE M2

PHASE M2

Elpro 13

exp

Terminal board

Drwg. No.

 1643

Sx 2

°

Dx 1

°

12.5 

µ

F

COMMON

COMMON

12.5 

µ

F

B

+

+

+

26
27
28

PEDESTRIAN MODE
ONE PULSE OPENS
ONE GATE LEAF ONLY

PULSE TWICE CONSECUTIVELY

TO OPEN BOTH GATE LEAFS

Содержание APROLI 280 BATT

Страница 1: ...olding down the remote control button Among the added features and improvements of ELPRO 13 in conformity to the European safety standards there is the mains rotary switch it is fitted to the box cove...

Страница 2: ...is supplied already pre filled with special oil to suit both high and low environment temperatures It allows the correct performance of APROLI 280 BATT within a temperature range from 20 C to 80 C APR...

Страница 3: ...is supplied already pre filled with special oil to suit both high and low environment temperatures It allows the correct performance of APROLI 280 BATT within a temperature range from 20 C to 80 C APR...

Страница 4: ...red to be fitted to the gate and the non locking type operator is advisable Both right hand and left hand applications are possible just by turning over the articulated arm and fitting it to the squar...

Страница 5: ...red to be fitted to the gate and the non locking type operator is advisable Both right hand and left hand applications are possible just by turning over the articulated arm and fitting it to the squar...

Страница 6: ...PILLAR 3 m GATE LEAF 100 Kg 400x400 20 mm FROM PILLAR SURFACE LINE 40 560 GATE STOP IN CLOSED POSITION CLOSED GATE LEAF OP EN GA TE LE AF 40 90 250 4 6 0 100 500x500 APPLICATION EXAMPLE 600x600 mm PIL...

Страница 7: ...PILLAR 3 m GATE LEAF 100 Kg 400x400 20 mm FROM PILLAR SURFACE LINE 40 560 GATE STOP IN CLOSED POSITION CLOSED GATE LEAF OP EN GA TE LE AF 40 90 250 4 6 0 100 500x500 APPLICATION EXAMPLE 600x600 mm PIL...

Страница 8: ...No 3 to semiautomatic OFF one pulse opens the gates a second pulse to 5 8 is needed to close the gates Any one pulse to 7 8 will open close or reverse the gates independently from the operation being...

Страница 9: ...No 3 to semiautomatic OFF one pulse opens the gates a second pulse to 5 8 is needed to close the gates Any one pulse to 7 8 will open close or reverse the gates independently from the operation being...

Страница 10: ...note that the electric cables must be removed from their terminals by loosening the fastening screws Never cut the electric cables Also make sure that the 230V mains switch No 3 is off before removin...

Страница 11: ...note that the electric cables must be removed from their terminals by loosening the fastening screws Never cut the electric cables Also make sure that the 230V mains switch No 3 is off before removin...

Страница 12: ...olding down the remote control button Among the added features and improvements of ELPRO 13 in conformity to the European safety standards there is the mains rotary switch it is fitted to the box cove...

Отзывы: