background image

7

6

PIC. 9

PIC. 7

PIC. 8

PIC. 10

PIC. 11

PIC. 12

EXAMPLE OF APPLICATIONS TO PILLARS OF VARIOUS DIMENSIONS. DISTANCES
ARE NOT BINDING AND ARE QUOTED FOR REFERENCE ONLY

It is recommended that all gates are provided with adequate gate stops both in open and closed gate positions. When a 5 m gate is
involved the weight must not be greater than 200 Kg and it is required to fit the gate with an electric lock, the operator must be non
locking type. With gates up to 2 m width, it is possible to install the locking type without electric lock.
See the examples and drawings on pages 6 - 7.

20 mm FROM PILLAR
SURFACE LINE

40

510

GATE STOP
IN CLOSED
POSITION

CLOSED GATE LEAF

OPEN GA

TE LEAF

40

90

200

460

100

°

APPLICATION EXAMPLE
400x400 mm PILLAR
2 m GATE LEAF - 110 Kg

APPLICATION EXAMPLE
500x500 mm PILLAR
3 m GATE LEAF - 100 Kg

400x400

20 mm FROM PILLAR
SURFACE LINE

40

560

GATE STOP
IN CLOSED
POSITION

CLOSED GATE LEAF

OPEN GA

TE LEAF

40

90

250

460

100

°

500x500

APPLICATION EXAMPLE
600x600 mm PILLAR
1.8 m GATE LEAF - 140 Kg

20 mm FROM PILLAR
SURFACE LINE

40

560

GATE STOP
IN CLOSED
POSITION

CLOSED GATE LEAF

OPEN GA

TE LEAF

60

90

300

460

100

°

600x600

ELECTRIC
LOCK

APPLICATION EXAMPLE
700x700 mm PILLAR
3 m GATE LEAF - 130 Kg

APPLICATION EXAMPLE
800x800 mm PILLAR
4 m GATE LEAF - 140 Kg

APPLICATION EXAMPLE
900x900 mm PILLAR
5 m GATE LEAF - 150 Kg

20 mm FROM PILLAR
SURFACE LINE

40

560

GATE STOP
IN CLOSED
POSITION

CLOSED GATE LEAF

OPEN GA

TE LEAF

170

90

350

580

100

°

700X700

ELECTRIC
LOCK

20 mm FROM PILLAR
SURFACE LINE

40

620

GATE STOP
IN CLOSED
POSITION

CLOSED GATE LEAF

OPEN GA

TE LEAF

170

90

400

580

100

°

800x800

ELECTRIC
LOCK

20 mm FROM PILLAR
SURFACE LINE

40

650

GATE STOP
IN CLOSED
POSITION

CLOSED GATE
LEAF

OPEN GA

TE LEAF

170

90

450

580

100

°

900x900

ELECTRIC
LOCK

Содержание APROLI 280 BATT

Страница 1: ...olding down the remote control button Among the added features and improvements of ELPRO 13 in conformity to the European safety standards there is the mains rotary switch it is fitted to the box cove...

Страница 2: ...is supplied already pre filled with special oil to suit both high and low environment temperatures It allows the correct performance of APROLI 280 BATT within a temperature range from 20 C to 80 C APR...

Страница 3: ...is supplied already pre filled with special oil to suit both high and low environment temperatures It allows the correct performance of APROLI 280 BATT within a temperature range from 20 C to 80 C APR...

Страница 4: ...red to be fitted to the gate and the non locking type operator is advisable Both right hand and left hand applications are possible just by turning over the articulated arm and fitting it to the squar...

Страница 5: ...red to be fitted to the gate and the non locking type operator is advisable Both right hand and left hand applications are possible just by turning over the articulated arm and fitting it to the squar...

Страница 6: ...PILLAR 3 m GATE LEAF 100 Kg 400x400 20 mm FROM PILLAR SURFACE LINE 40 560 GATE STOP IN CLOSED POSITION CLOSED GATE LEAF OP EN GA TE LE AF 40 90 250 4 6 0 100 500x500 APPLICATION EXAMPLE 600x600 mm PIL...

Страница 7: ...PILLAR 3 m GATE LEAF 100 Kg 400x400 20 mm FROM PILLAR SURFACE LINE 40 560 GATE STOP IN CLOSED POSITION CLOSED GATE LEAF OP EN GA TE LE AF 40 90 250 4 6 0 100 500x500 APPLICATION EXAMPLE 600x600 mm PIL...

Страница 8: ...No 3 to semiautomatic OFF one pulse opens the gates a second pulse to 5 8 is needed to close the gates Any one pulse to 7 8 will open close or reverse the gates independently from the operation being...

Страница 9: ...No 3 to semiautomatic OFF one pulse opens the gates a second pulse to 5 8 is needed to close the gates Any one pulse to 7 8 will open close or reverse the gates independently from the operation being...

Страница 10: ...note that the electric cables must be removed from their terminals by loosening the fastening screws Never cut the electric cables Also make sure that the 230V mains switch No 3 is off before removin...

Страница 11: ...note that the electric cables must be removed from their terminals by loosening the fastening screws Never cut the electric cables Also make sure that the 230V mains switch No 3 is off before removin...

Страница 12: ...olding down the remote control button Among the added features and improvements of ELPRO 13 in conformity to the European safety standards there is the mains rotary switch it is fitted to the box cove...

Отзывы: