background image

3

2

PIC. 1

CUTAWAY VIEW OF THE ELECTRIC MOTOR ASSEMBLY

AND HYDRAULIC JACK

AVAILABLE TYPES: NON LOCKING - LOCKING - WITH FLOW REGULATOR

TWO-WAY LOCKING
VALVE ASSEMBLY

APROLI

  280 

BATT

INSTRUCTIONS FOR THE INSTALLATION OF APROLI 280 BATT TO SWINGING
DOUBLE GATES WITH VERY LARGE PILLARS

PIC. 2

First loosen the fastening screws to remove the cover. To do this, open the hinged door with the supplied key; one of the two fastening
screws is there. After the removal of the cover, the electro-hydraulic assembly is fully exposed, ie. “electric motor/hydraulic jack” fitted
with the pressure safety valves that control the thrust/pushing power of the operator and the emergency release in events like power
failure. It also includes a bracket, designed to provide fixing facility to a wall or pillar and a suitable outlet for the cables; an articulated
arm, adjustable to meet the most various distance requirements on site applications; and a shoe bracket to be fixed to the gate. The
operator is supplied already pre-filled with special oil to suit both high and low environment temperatures. It allows the correct
performance of APROLI 280 BATT within a temperature range from –20

°

C to +80

°

C. APROLI 280 BATT is produced and tested in the

workshops of MECCANICA FADINI which guarantees the long lasting reliability of this product in time.

it is recommended to follow these instructions to achieve a perfect application of the operator.

PRESSURE SAFETY
VALVE “CLOSE”
GREEN

PRESSURE SAFETY
VALVE “OPEN”
RED

OIL RESERVOIR

TERMINAL PLUG
COVER

TERMINAL PLUG

EARTH WIRE

OIL RESERVOIR
REAR CAP

0.25 HP
ELECTRIC MOTOR

HYDRAULIC LOBE
PUMP

JACK END CAP

1

st

 PISTON

RACK

RELEASE LEVER

PISTON LINER

SHAFT SUPPORT

SQUARE INDENTED
SHAFT

2

nd

 PISTON

PISTON LINER

MAIN ASSEMBLY
BLOCK WITH MOTOR
AND HYDR. JACK

“B”

“C” “A”

BASE AND
FIXING BRACKET

STUD
BOLT

ASSEMBLY ELEC.
MOTOR HYDR. JACK

PROTECTION
COVER

FIXING
SCREWS

OPEN STOP ASSEMBLY
14 E22 NUT, STUD BOLT,
ADJUSTER COVER.
LEFT-HAND WASHER Ø 8.5
8M E13 NUT

RETAINING
GRUB SCREW

DRIVING
BENDED
ARM

BENDED ARM
PLUG PROFILE

BOLT AND
NUT

STRAIGHT
ARM COVER

STRAIGHT
ARM.
ADJUSTABLE

FIXING
SHOE

SCREW FOR
ADJUSTMENT

BUSH

ARTICULATED ARM
LEFT-HANDED

Lh

Содержание APROLI 280 BATT

Страница 1: ...olding down the remote control button Among the added features and improvements of ELPRO 13 in conformity to the European safety standards there is the mains rotary switch it is fitted to the box cove...

Страница 2: ...is supplied already pre filled with special oil to suit both high and low environment temperatures It allows the correct performance of APROLI 280 BATT within a temperature range from 20 C to 80 C APR...

Страница 3: ...is supplied already pre filled with special oil to suit both high and low environment temperatures It allows the correct performance of APROLI 280 BATT within a temperature range from 20 C to 80 C APR...

Страница 4: ...red to be fitted to the gate and the non locking type operator is advisable Both right hand and left hand applications are possible just by turning over the articulated arm and fitting it to the squar...

Страница 5: ...red to be fitted to the gate and the non locking type operator is advisable Both right hand and left hand applications are possible just by turning over the articulated arm and fitting it to the squar...

Страница 6: ...PILLAR 3 m GATE LEAF 100 Kg 400x400 20 mm FROM PILLAR SURFACE LINE 40 560 GATE STOP IN CLOSED POSITION CLOSED GATE LEAF OP EN GA TE LE AF 40 90 250 4 6 0 100 500x500 APPLICATION EXAMPLE 600x600 mm PIL...

Страница 7: ...PILLAR 3 m GATE LEAF 100 Kg 400x400 20 mm FROM PILLAR SURFACE LINE 40 560 GATE STOP IN CLOSED POSITION CLOSED GATE LEAF OP EN GA TE LE AF 40 90 250 4 6 0 100 500x500 APPLICATION EXAMPLE 600x600 mm PIL...

Страница 8: ...No 3 to semiautomatic OFF one pulse opens the gates a second pulse to 5 8 is needed to close the gates Any one pulse to 7 8 will open close or reverse the gates independently from the operation being...

Страница 9: ...No 3 to semiautomatic OFF one pulse opens the gates a second pulse to 5 8 is needed to close the gates Any one pulse to 7 8 will open close or reverse the gates independently from the operation being...

Страница 10: ...note that the electric cables must be removed from their terminals by loosening the fastening screws Never cut the electric cables Also make sure that the 230V mains switch No 3 is off before removin...

Страница 11: ...note that the electric cables must be removed from their terminals by loosening the fastening screws Never cut the electric cables Also make sure that the 230V mains switch No 3 is off before removin...

Страница 12: ...olding down the remote control button Among the added features and improvements of ELPRO 13 in conformity to the European safety standards there is the mains rotary switch it is fitted to the box cove...

Отзывы: