background image

IMPORTANT NOTE:

 THIS OWNER'S MANUAL IS PROVIDED AS AN 

INSTALLATION AND OPERATING AID. FACTOR ELECTRONICS DOES NOT 

ASSUME ANY RESPONSIBILITY AS TO ITS ACCURACY AND SHALL NOT BE 

LIABLE IN TORT OR CONTRACT FOR ANY DIRECT, CONSEQUENTIAL OR 

INCIDENTAL LOSS OR DAMAGE ARISING FROM THE INSTALLATION, USE OR 

INABILITY TO USE THIS PRODUCT.

WARNING: 

TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK DO NOT 

EXPOSE THIS APPLIANCE TO WATER, RAIN OR MOISTURE. THIS APPLIANCE 

SHOULD NOT DAMPENED BY WATER DROPS OR SPLASHING. CONTAINERS OF 

LIQUID SUCH AS VASES SHOULD NOT BE PLACED ON THIS APPLIANCE.

Immediately upon receipt, inspect the unit and shipping container for indications of improper 

handling or in-transit damage. This equipment was carefully inspected and tested before 

leaving the factory. Notify the Transportation Company, Wholesaler or Retailer immediately if 

any damage is found. Be sure to save the carton and packing material as evidence of damage 

for later inspection. DO NOT SHIP the unit back to the factory unless authorized to do so by the 

factory. IN TRANSIT DAMAGES ARE NOT COVERED BY THE WARRANTY.  

DO NOT INSTALL OR 

ATTEMPT TO OPERATE THIS UNIT IF IT HAS BEEN DAMAGED. 

IMPORTANT SAFETY INSTRUCTIONS

• Read and keep these instructions.

• Heed all warnings and follow all instructions contained within this manual.
• Do not use this unit near water.

• Clean only with dry cloth.

• Do not block any ventilation openings. Install in accordance with the manufacturer’s 

instructions.
• Do not install near any heat sources such as radiators, heat registers, stoves, or other 

apparatus (including 

amplifiers) that produce heat.

• Do not defeat the safety purpose of the polarized or grounding-type plug. A polarized plug 

has two blades 

with one wider than the other. A grounding type plug has two blades and a third 

grounding prong. The wide blade or the third prong are provided for your safety. If the provided 

plug does not fit into your outlet, consult an electrician for replacement of the obsolete outlet.

• Protect the power cord from being walked on or pinched particularly at plugs, convenience 
receptacles, and 

the point where they exit from the apparatus.

• Only use attachments/accessories specified by the manufacturer.

• Unplug this apparatus during lightning storms or when unused for long periods of time.

• Refer all servicing to qualified service personnel. Servicing is required when the apparatus 
has been 

damaged in any way, such as when the power-supply cord or plug is damaged, liquid 

has been spilled or objects have fallen into the apparatus, the apparatus has been exposed to 

rain or moisture, does not operate normally, or has been dropped.

• Operate the product only with the voltage specified on the unit. Fire and/or electric shock 

may result if a 

higher voltage is used.

• Do not modify, kink, or cut the power cord. Do not place the power cord in close proximity to 

heaters and 

do not place heavy objects on the power cord and/or the product itself, doing so 

may result in fire or electrical shock.

• Replace the protective cover over the speaker terminals after installation. Do not touch the 
70V speaker 

terminals as electric shock may result.

• Ensure that the safety ground terminal is connected to a proper ground. Never connect the 

ground to a gas 

pipe, as a severe explosion and/or fire may result.

• Be sure the installation of this product is stable, avoid slanted surfaces as the product may 
fall and cause 

injury, property damage, electrocution and/or fire.

• Note when the unit is turned off it is not completely disconnected from the wall AC power 

outlet. Do not open 

the cover unless the device is unplugged from the wall AC power outlet.

[email protected]

       www.factorelectronics.com

Содержание V-RVC-PRO

Страница 1: ...V RVC PRO Owners Manual info factorelectronics com www factorelectronics com PREMIUMAUDIOVIDEOANDPOWERPRODUCTS ...

Страница 2: ...er A grounding type plug has two blades and a third grounding prong The wide blade or the third prong are provided for your safety If the provided plug does not fit into your outlet consult an electrician for replacement of the obsolete outlet Protect the power cord from being walked on or pinched particularly at plugs convenience receptacles and the point where they exit from the apparatus Only u...

Страница 3: ...arts 1 x V RVC PRO in wall mic line preamp 2 x Male RJ45 crimp on connectors 4 x Philips mounting Screws 2 x Keys 1 x V RVC PRO manual Installation Using Factor Electronics Amplifiers The V RVC PRO can be connected to any Factor Electronics amplifier by connecting a cat5e or cat6 cable to the V RVC RJ45 output jack then connecting the cat5e or cat6 cable to the V RVC input provided on the back pan...

Страница 4: ...g multiple V RVC PRO units Shielded cable is not mandatory however it may be necessary if EMI or RF interference is present at the installation site The V RVC PRO includes two RJ45 crimp on connectors Use a good quality RJ45 crimping tool to complete the connections Diagram B info factorelectronics com www factorelectronics com TIA EIA 568A Wiring Up to three V RVC PRO units can be daisy chained o...

Страница 5: ...the RJ45 input of the V RVC PRO Then connect the RJ45 output of the V RVC PRO to the RJ45 input of the second V RVC PRO Now connect the RJ45 output of the last V RVC PRO to the V RVC input of the Factor Electronics amplifier Diagram D X Music Side View Power In RJ45 Out Connect The Cat5e To Any Factor Electronics Amplifier V RVC Input info factorelectronics com www factorelectronics com IN1 OUT1 I...

Страница 6: ...able run from the V RVC PRO back to the amplifier and terminate at the V RVC RJ45 We recommend Cat5 6 cable runs of 100 max and shielded Cat5 6 runs of 200 300 max 2 Cat5 6 short cable run to the V RVC RJ45 then run a balanced 2 conductor 22 24awg shielded cable and terminate at the amplifier Using this method runs of 500 will be achievable Diagram E 1 Cat5 6 100 Shielded Cat5 6 200 Balanced Conne...

Страница 7: ...onics com OUT IN RJ45 RJ45 1 Four selectable Dip switches RVC remote volume control 100Hz cut 15db pad 24V phantom power See detailed explanations on the next page 5 RJ45 Out1 Connect this to another V RVC PRO input in a daisy chain or to the V RVC input of the amplifier 2 VOX sensitivity adjustment 3 RJ45 IN Connect this to the OUT of another V RVC PRO in a daisy chain or from the output of an X ...

Страница 8: ... volume controller by setting the switch to ON All other V RVC s must have this dipswitch set to OFF If more than one RVC is set to ON it will be impossible to control the master volume of the amplifier NOTE To effectively control the master volume of the amplifier from the V RVC set the amplifier master volume to 75 or 2 3rds full volume and control the overall level from the V RVC If the amplifi...

Страница 9: ...tio Line 80dB Power Requirements 24V DC Dimensions Imperial W 2 75 x H 5 9 x D 1 96 Dimensions Metric W 115 5mm x H 114 5mm x D 45mm Shipping Weight 3lb 1 36kg Warranty 3 Years Specifications In an effort to provide our customers with the latest advancements in technology Factor Electronics Specifications are subject to change from time to time without notice Contact Information Factor Electronics...